KEYENCE GC-1000/GC-1000R Safety Controller

From: | Author:Wang | Time :2026-06-03 | 651 visit: | 🔊 Click to read aloud ❚❚ | Share:

KEYENCE GC-1000/GC-1000R Safety Controller

The original factory manual for KEYENCE GC series programmable safety controller is divided into two types: GC-1000 (transistor safety output) and GC-1000R (relay safety output), which meet the highest industrial safety level of SIL3/PL e/Cat.4. It relies on GC Configurator software graphical programming to adapt to safety control of emergency stop, safety door, grating, hands, shielding (Muting), PSDI press safety and other full scene equipment. The document explains safety specifications, hardware parameters, installation wiring, functional blocks, debugging and maintenance, and compliance certification from multiple dimensions.


General Provisions and Safety Management Standards

1. Warning grading

The document is divided into three types of warnings: DANGER (fatal danger), Warning (serious injury hazard), and NOTICE (equipment damage). The entire machine is only for routine industrial equipment safety control and is strictly prohibited from being used in rail transit, aviation, nuclear power, medical, and explosion-proof hazardous areas.

2. Statutory responsibilities of the safety manager

The person in charge of equipment safety shall complete the entire process in accordance with ISO13849 and ISO12100: risk assessment → defining safety functions → software program verification → overall functional acceptance of the machine, and overall safety testing before startup; After modifying the program/hardware, retesting is necessary; When the non safety PLC signal is linked to the safety circuit, the programming is forced to limit that the non safety signal can only start the safety output after the safety circuit meets the conduction conditions, to prevent false starting.

3. Definition of Product Safety Status

GC safety default fault state: all safety inputs OFF, safety outputs S-OFF disconnected; Only devices that automatically cut off output due to faults (emergency stop, Class 4 grating, safety door switch) can be connected, and the backend load must be powered off and shut down.


Differentiation of hardware specifications between two products

Project GC-1000 GC-1000R

Body size 60 × 95 × 90mm 85 × 95 × 90mm Weight approximately 260g approximately 360g

Safe input Si 16 points (PNP type, only supports contact/PNP sensors, NPN direct connection prohibited) 16 points

Safe output 4-channel PNP semiconductor S-OUT 3-channel normally open relay SRo+4-channel semiconductor S-OUT

Auxiliary AUX outputs 4 non safety transistor outputs 4 AUX outputs

Test output To 4 channels (for dual channel short circuit diagnosis) 4 channels

Expansion capability up to 10 expansion modules+4 remote IO units that cannot be externally connected

Communication interface 2 x GC Link, USB, Ethernet (Modbus/TCP, EtherNet/IP, PROFINET)

Power supply DC24V (± 20%) Class2 power supply, overall power consumption ≤ 200mA

Electrical parameters

Safe input: ON ≥ 11V, OFF ≤ 5V, cable length up to 100m, built-in short circuit self-test;

Semiconductor S-OUT: PNP output 500mA, load ≤ 0.5 μ F, output ≤ 30m;

GC-1000R relay output: resistive 250VAC/6A, inductive AC15 2A/DC13 1A, requiring 10A fast melting in series at the front end, with a maximum cable length of 100m;

PFHD hazard failure probability: single channel S-OUT self diagnosis opening ≈ 4.01 × 10 ⁻⁹/h, dual channel ≈ 1.01 × 10 ⁻⁹, service life of 20 years.

environmental conditions

Working temperature -10~+55 ℃, storage and transportation -25~+70 ℃, humidity 5~85%, no condensation; Altitude ≤ 2000m, pollution level 2; The whole machine needs to be installed in a control cabinet with an IP54 rating or higher, and installed on DIN35 guide rails.

Installation and wiring specifications

Cabinet installation: A heat dissipation gap of ≥ 30mm is reserved around the entire machine, and the distance between multiple module stacks is ≥ 60mm. The DIN rail is reliably grounded;

Cable specifications: Terminal adaptation 0.2~1.5mm ² (AWG16~26), relay terminal 0.2~2.5mm, wire temperature resistance ≥ 80 ℃, wire stripping 10mm;

Rigid wiring requirements

The safety output load must be connected to the 0V side, and it is forbidden to connect to+24V, otherwise the logic reversal may cause false startup;

When implementing PL e/SIL3 in a single channel, the output cable needs to be protected to avoid power line short circuits;

Inductive load parallel absorption circuit, prohibit large capacity capacitive absorbers;

Four types of OSSD grating dual channel access are required to achieve dual channel short-circuit protection and meet PLd/e.

Bus configuration: Ethernet uses Category 5e shielded twisted pair cables, GC Link comes with dedicated cables, and remote IO can be wired up to 120m away.


Software Function Blocks and Application Rules (Core Programming Unit)

Relying on the GC Configurator software for drag and drop programming, it has built-in standardized security function blocks, all of which comply with ISO and IEC security standards:

1. Reset function (manual/dual reset/presence detection reset)

Standard reset: The reset button must be installed outside the danger zone and in a visible position. Pulse input is recommended, and there is a risk of false reset due to noise from edge input;

Double reset: There are two buttons, and the last person to leave operates the second reset;

Existence of reset: Equipped with safety carpet/grating signals for reset interlocking.

2. Various Muting shielding functions (sequence/parallel/crossover/position shielding)

Sequence masking is the most commonly used, requiring 2-4 independent safety sensors to trigger masking, and PLC software signals are prohibited from triggering masking;

Parallel/Cross Shielding: Two shielded sensor cables are divided into cable trays, different shielded wires, or one open and one closed contact to prevent accidental shielding due to short circuits in the defense cable;

Shielding indicator lights should be selected according to regulations, and mechanical protection must be added for overtime shielding to prevent personnel from entering the danger zone by mistake;

Overpass: It must be operated with handheld jog control, and the hazardous area can be seen on site. An emergency stop switch should be installed nearby.

3. Manual mode MMC, bypass, door unlock, PSDI stamping dedicated

Manual mode: Three point enable/jog switch is required, automatic start is prohibited, and emergency stop remains valid throughout the entire process. It is recommended to switch modes with the key knob;

Bypass: Only for the shortest necessary duration, the bypass signal must meet the corresponding safety level;

PSD press function: limited to equipment that can be stopped urgently throughout the entire process, equipped with a Type 4 grating. This function is disabled for Japanese stamping equipment;

Door interlock unlocking: The door lock can only be unlocked when the machine reaches a safe speed/torque/shutdown state.

4. Logical block: AND/OR/NOT

Use with caution when reversing NOT, input disconnection can cause the output to be normally open and prone to accidental startup; The OR block prohibits non safety signals from opening safety circuits.


Communication and System Expansion

Ethernet: Compatible with multiple protocols, it is recommended to enable authorization codes for non secure communication reset to avoid remote false triggering of power on;

GC Link: Connect with the Keyence GS series safety door lock, read the door lock switch/locking status, and achieve door lock interlock control;

System architecture: GC-100 host+local expansion+remote IO, bus extension unit can remotely deploy IO.


Fault diagnosis, maintenance, and spare parts replacement

1. Fault classification (body LED+screen prompt)

Info minor alarm, Alert exception, Error single output cut-off, Fatal whole machine safety output tripping and shutdown.

2. Regular maintenance

First installation acceptance: full circuit wiring+full functional inspection;

Annual inspection: Full testing of the entire machine's safety functions, and manual start stop emergency stop verification is required to cut off the self diagnostic closed circuit;

After changing lines/equipment/long-term shutdown, it is necessary to retest the safety of the entire machine.

3. Whole machine replacement

The host has a built-in system memory card, which can be replaced with a new one by unplugging and inserting the card to import the original program. After power on, the CRC check fault can be eliminated to start production.


Product Compliance Certification

Through T Ü V, UL, CSA, CE, KC and other multinational certifications, it complies with IEC61508 (SIL3), IEC62061 (SILCL3), ISO13849-1 (Cat.4/PL e), EN61131-6 safety PLC standards, and meets the European and American Machinery Directive.


  • Heidenhain ROQ 425 2048 03S17-58 - Encoder cable +-10M
  • Plettac VM328GB H.XM90-06 - Control Panel
  • Moeller Vanderlande Eaton RA-SP2-HE-343(230)-2K2/C3A-061 - Motor Controller
  • Delta VFD007B23A VFD-B VFD-PU01 - Inverter Frequency Drive 1 HP 3Phase
  • SIEMENS 6ES7 214-1BC01-0XB0 6ES7 291-8GC00-0XA0 - SIMATIC S7-200 CPU214 plus memory
  • DRPP Dutch Reverse Pulse Coating 01DALCMMB COM1519020 - Coating Equipment Module
  • DRPP Dutch Reverse Pulse Coating 01DALCMMB COM1552025 - Coating Equipment Module
  • ELIN COMMANDER VL75 - VARIABLE FREQUENCY INVERTER 7.5kW
  • Mitsubishi Melsec F2-40M - Programmable Controller
  • INDRAMAT TDM3.2-020-300-W0 / MOD13/1X013-002 - AC SERVO CONTROLLER
  • ABB ACS550-01-03A3-4 - Drive Inverter
  • BECKHOFF CX2900-0192 - Battery Module
  • Pilz PNOZ m1p ETH 773103 - Safety Relay Module
  • FHF AWS 150mm - spark + huster signal horn 230VDC SIGNAL ALARM CLOCK
  • Danfoss VLT 2050 195H3409 - Variable Speed Drive Frequency Inverter 6.1kVA
  • Danfoss VLT 2030 195H3405 - Frequency Inverter 3.2kVA
  • Danfoss EKC204A1 - Refrigeration Controller
  • FALKENBERG ZJ20-M40MB-DPS-V2 - Controller Module
  • Siemens 6AV6 545-0BA15-2AX0 - Touch Panel TP 170A
  • SMC SR1 VVQ1000 VQ1101-5 - SERIAL UNIT Plus 12Module Plus 3Module
  • SMC SR1 VQ1101-5 VQ1101-5-Q - SERIAL UNIT with 11 module plus 5 module total 16mdl
  • Schneider Electric LE4D09P7 - starter with isolator
  • X-rite 968 - Spectrophotometer
  • Schneider Electric 24469 C60 C20A - MULTI9 Circuit Breaker
  • Schneider Electric RUMC2AB1BD + RUZC2M - Relay
  • Schneider Electric 24538 C60 D10A - MULTI9 Circuit Breaker
  • Siemens 6ES7412-2XG00-0AB0 - Simatic S7 CPU412-2
  • B&R X20CS1030 X20BM01 - Communication Module
  • Siemens 6ES7412-2XG00-0AB0 - Simatic S7 CPU412-2
  • B&R X20CS1030 X20BM01 - Communication Module
  • MOXA EDS-408A-MM-ST - Ethernet Device Switch
  • Siemens 6SL3055-0AA00-5AA3 - Sensor Module
  • Jungheinrich GNM5460-G18.5-MIR1 - Steering motor forklift
  • Pilz 302051 PSS1 PS 24 - POWER SUPPLY
  • SIEMENS 6SL3210-1KE14-3AF1 - Inverter Drive
  • SIEMENS 6SL3210-5FB10-8UF0 - Inverter Drive 0.75kW
  • Pilz PNOZ XV3.1P 777530 - Safety Relay Module
  • HITACHI CPM-E3 33016210 - HIZAC PLC Module
  • Telemecanique SCHNEIDER ELECTRIC ATV28HU29M2 - Frequency Inverter VARIATOR 1.5kW
  • SCHMERSAL SRB-NA-R-C.33-230V - Safety Relay
  • CERUTTI RE 51052 - REFERENCE SPEED MODULE
  • Cerutti RE 51025 - Power Supply Module
  • CERUTTI RE 51115 - SIGNAL FEEDBACK ISOLATORS
  • CERUTTI RE52000 - POWER SUPPLY MODULE
  • Omron CP1E-N14DT1-D - PLC CPU Unit
  • Mannesmann DEMAG BHZ 380/40-1 - Motor Brake Component
  • SIEMENS LANDIS & STAEFA NRUD/A - Controller Unit
  • Allen-Bradley 1768-ENBT - CompactLogix Ethernet/IP Module
  • SEW Eurodrive MDX61B0011-5A3-4-00 - Drive Inverter
  • BTI AWAX-ANA-78-24V-AC/DC - Safety Relay Contact
  • Mannesmann DEMAG BHZ 380/40-1 - Motor Brake Component
  • elobau 462121G1 - Safety Relay
  • SIEMENS LANDIS & STAEFA NRUD/A - Controller Unit
  • Siemens 6SL3055-0AA00-5AA3 - Sensor Module Cabinet-Mounted
  • TELEMECANIQUE LC1F330 - Contactor 220/230V 3-pole
  • BTI AWAX-ANA-78-24V-AC/DC - Safety Relay Contact
  • SEW Eurodrive MDX61B0011-5A3-4-00 - Drive Inverter
  • Siemens 6SL3055-0AA00-3HA0 - Terminal Module TM17
  • Allen-Bradley 1768-ENBT - CompactLogix Ethernet/IP Module
  • KIMO MM 0.75FMC-emc - MotorMaster Controller
  • Banner DX80G2M6S-PM8 - Wireless Gateway 2.4GHz
  • MITSUBISHI FX3U-48MR/ES - FX3U PLC Base Unit
  • TAC Xenta 422A - Universal Input Module
  • SCHNEIDER ELECTRIC C1632D160 - Circuit Breaker
  • SCHNEIDER TM221CE16R - Modicon M221 PLC Controller
  • STAR 750W-TE - Motor Component
  • OMRON 3G3EV-A4004MA-CUES1 - Sysmac AC Drive
  • SIEMENS 6ES7 332-5HF00-0AB0 - Analog Output Module
  • SICK CDB410-001 - Connection Module
  • SICK CDM410-0001 - Connection Module
  • Siemens 3UF5001-3AN00-1 - SIMOCODE-DP Basic Unit
  • UNITRONICS IO-AI4-AO2 - I/O Expansion Module
  • SIEMENS 6ES7 151-8AB01-0AB0 - SIMATIC ET200S CPU
  • BW Technologies SS315-001073 - GasAlertMicro 5 IR Gas Detector
  • SIEMENS 3SE5322-1SB21 - Sirius Safety Position Switch
  • SIEMENS 6ES7 278-4BD32-0XB0 - Memory Module
  • SCHNEIDER PM8ECC - PowerLogic Ethernet Communication Module
  • SIEMENS 7KT1131 - Measuring Instrument
  • SIEMENS 6ES5951-7LB21 - SIMATIC S5 Power Supply
  • SCHROFF / Ferag SPN124 5.941.051 - Power Supply
  • Emerson / HART MODEL 275 - Field Communicator
  • Pilz PNOZ m B1 772101 - Safety Controller Relay
  • DANFOSS FC-202P1K5T4E20H1 131B8290 - VLT Aqua Drive 1.5kW
  • SIEMENS RVP351 - Heating Controller
  • SCHNEIDER ELECTRIC ATV212HU30N4 - Altivar Variable Speed Drive
  • Danfoss AK-PC 781 080Z0186 - ADAP-KOOL Controller
  • Omron R7D-BP02HH9 - AC Servo Drive With Filter
  • TELEMECANIQUE ATV31HU22M2 - Altivar Variable Speed Drive
  • SIEMENS 6SL3040-0MA00-0AA1 6SL3055-0AA00-2TA0 6SL3054-0CF00-1AA0 - Sinamics Control Unit Component
  • SIEMENS 6SL3040-0MA00-0AA1 6SL3055-0AA00-2TA0 6SL3054-0CF00-1AA0 - Sinamics Control Unit Component
  • EUCHNER STP3A-2131A024M 091493 - Safety Switch
  • OMRON E3S-AT91 E3S-AT91-D E3S-AT91-L - Photoelectric Sensor
  • Danfoss VLT 2040 195H3307 195H6522 - Inverter Drive EMC Filter
  • Schneider Electric 24541 - Multi9 C60 Circuit Breaker D20A
  • Allen-Bradley 1769-PB4 - Compact I/O Power Supply
  • KYOSAN FPF07P-AC100C - Power Supply Module
  • SIEMENS 6ES7 354-1AH00-0AE0 - Positioning Module
  • CAREL PC01000CS0 - pCO1 Controller
  • SIEMENS 3RW4026-1BB14 - Sirius Soft Starter
  • B&R 8AC120.60-1 - ACOPOS Plug-in Module
  • ASTERO A8M25J G83.6K - Gear Motor
  • B&R X20SO2530 - Safe Digital Output Module
  • BARKSDALE UDS3V3/10bar/4-20mA - Electronic Pressure Switch
  • B&R X20DI8371 - Digital Input Module
  • OMRON CJ1W-DA041 - Analog Output Unit
  • CROWN HD2500 153076 - Hand Pallet Truck Component
  • LENZE E82EV152_2B 00450762 - Frequency Inverter
  • LENZE E82EV152_2C 13436167 - Frequency Inverter
  • SETEX DM016V3 BGC04112 - Module
  • JUMO TYA-110/325400TR 70/00088113 - Thyristor Power Controller
  • CROWN 130955 - Access 6 Guidance Module
  • Siemens 6FX3002-5CL02-1CA0 - Servo Cable
  • TAC Xenta 401:C - Controller Module
  • SETEX LOGIMAT P160 - CPU Board
  • SCHNEIDER ELECTRIC BMXAMI0810 - Analog Input Module
  • SCHNEIDER ELECTRIC BMXP342020 - Modicon M340 PLC Processor
  • SIEMENS 6SL3224-0BE23-0AA0 - SINAMICS Power Module
  • B&R X20DS1928 - Digital Module
  • TOSHIBA VFNC1S-2004PL-W - Transistor Inverter
  • WEIDMULLER UR20-4AI-UI-12 1394390000 - u-remote Analog Input Module
  • REXROTH VT5005 S16 R5 11110027 - Proportional Amplifier Card
  • HMS Industrial AB7126-B ABC-PDP-EH - Anybus X-gateway Interface PROFIBUS-DP
  • GREIN SAB/BOX A5R - Safety Relay Box
  • EMERSON CONTROL TECHNIQUES UD51 STDJ19 - 2nd Encoder Option Module
  • SCHNEIDER LV431549 - Compact NSX Circuit Breaker
  • SIGMATEK DTO163 05-007-163 - Digital Output Module
  • OMRON CJ2M-CPU31 - PLC CPU Unit
  • SIGMATEK DAI411 05-020-411 - Analog Input Module