1. Product Overview

This document covers three SCXI signal conditioning chassis used to provide power supply, backplane communication, heat dissipation, and mechanical support for SCXI modules.

SCXI-1000:4 slot, AC power supply

SCXI-1000DC: 4 slots, DC 9.5-16V power supply

SCXI-10001:12 slot, AC power supply


2. Front and rear panel structure

Front panel components (table)

Component Function

Power switch for the whole machine on/off

Power on status indicator light

Reset key to reset Slot 0 and all modules

Address switch/jumper setting chassis address (0-31)

Module rail positioning SCXI module connected to backplane

Rear panel components

AC model: power input module, voltage selection knob, main fuse, fan, backplane fuse

DC model: DC power interface F1(6.3A)、F2(3.15A)、 Backboard fuse


3. Core configuration

(1) Chassis address setting

Supports 32 addresses (0-31), multiple chassis systems must be distinguished

SCXI-1000/1001: Front panel 5-position DIP switch (1/2/4/8/16 weighted)

SCXI-1000DC: Internal 3 sets of jumper wires (0/8/16 weighted)

Default address: 0

(2) Voltage and fuse configuration

The AC model supports 100/120/220/240V, and the rear knob switch must be matched with the corresponding fuse. SCXI-1000/1001 Voltage Fuse Comparison Table (Key)

Model voltage main fuse backboard fuse

SCXI-1000 120V T0.5A 1.5A

SCXI-1000 240V T0.25A 1.5A

SCXI-1001 120V T3.0A 4A

SCXI-1001 240V T1.6A 4A

SCXI-1000DC: Input 9.5-16VDC, F1=6.3A, F2=3.15A, backplane 1.5A

4. Installation steps

Set the chassis address (default 0 for single chassis)

Place the chassis and leave a heat dissipation space of ≥ 10cm at the rear

Confirm voltage/fuse, connect to power supply

Install SCXI module and wiring

Install filler panels

Power on and configure in MAX


5. Maintenance and upkeep

Fan filter: Regular water washing and dust removal to prevent overheating

Fuse replacement: The same specification delay fuse must be used

The module does not support hot plugging, and live plugging can easily burn fuses/backboards


6. Technical specifications

Electrical Characteristics

Analog power supply: ± 18.5~25V, ripple ≤ 1.5V

Digital power supply:+4.75~5.25V, ripple ≤ 50mV

Power consumption per slot: 7W

SCXI-1000DC maximum current: 5.5A@9.5V

Physics and Environment

Weight: SCXI-1000DC (3.3kg), 1000 (3.9kg), 1001 (6.8kg)

Working temperature: 0-50 ℃

Safety standards: IEC 61010-1, UL 1244, CSA C22.2 No.61010-1

EMC:EN 55011、FCC Part 15A


7. Software support

Driver: NI DAQmx/Traditional NI DAQ

Development environment: LabVIEW, LabWindows/CVI, Measurement Studio

Working modes: reuse mode (shared DAQ channel), parallel mode (dedicated channel)


Key questions and answers

Question 1: What is the purpose of the SCXI chassis address? How to set the address for 1000/1001 and 1000DC respectively?

Answer: The chassis address is used to distinguish devices in multi chassis systems and supports up to 32 cascaded devices.

SCXI-1000/1001: Front panel 5-digit DIP switch, weighted values of 1/2/4/8/16, and the sum is the address.

SCXI-1000DC: Three sets of jumper wires (0,+8,+16) are added together to obtain the address.

The default value is 0, and there is no need to modify the single box.

Question 2: What is the most common reason for SCXI chassis not booting up? How to troubleshoot and repair?

Answer: The most common reason is that the live plug-in module causes the fuse to melt or the voltage/fuse to not match. Troubleshooting steps:

Power off, check the power cord and voltage selection knob

Check if the main power fuse is blown

Check the simulated power fuse on the lower back panel of the fan

Replace the delay fuse with the same specifications and power it on again

Prohibiting module hot plugging can prevent this malfunction.

Question 3: What are the core differences between SCXI-1000DC and AC models? What are the differences in applicable scenarios?

answer:

Power supply difference: 1000DC is DC 9.5-16V (battery/vehicle); The AC model operates between 100-240VAC.

Fuse: DC model dual external fuse (6.3A/3.15A); The AC model is equipped with voltage matching delay insurance.

Scenario: 1000DC is suitable for in car, outdoor, and non mains environments; AC models are suitable for fixed measurement and control in laboratories and production lines.

  • ABB 5SHX1445H0002 Power Semiconductor Module
  • ABB CI853-1 Communication Interface Module
  • ABB CI858-1 Communication Interface Module
  • ABB PM861K01 Processor Unit
  • ABB REM610 Motor Protection Relay
  • ABB 5SDF1045H0002 Power Semiconductor Module
  • Lilaas R01TS10A0H03-00 Marine Control Lever Module
  • Metso 1H13767C-3 - Paper Pinion Hand Guide Bevel
  • Metso LK-2101 - Linkage Kit
  • Metso A413510 - Rack Enclosure 21 Slots
  • Metso ND9106HU-K - Intelligent Valve Controller
  • Metso D201190L - AO4H Analog Module
  • Metso WIN1011187 - Top Slitter Assembly
  • Metso 251920 - Automation Component
  • Metso LK-1871 - Linkage Kit
  • Metso SE200N529 - XP Power Supply 115/230 VAC
  • Metso Shadow Brown Fleece - Harkila Half Zip Sweater
  • Metso DI8P - Valmet Digital Input Module
  • Metso DO8S0 - Valmet Digital Output Module
  • Metso AO8C - Valmet Analog Output Module
  • Metso AO4H - Valmet Analog Output Module
  • Metso AI8C - Valmet Analog Input Module
  • Metso PDCF2529 - Shaft Sleeve
  • Metso ST2.8 - Lokotrack Owners Manual & Parts Book
  • Metso 500836-M1 - Impeller Pump Release Collar Assembly
  • Metso RKN 33 XT - Valve Service Kit Pack
  • Metso PDCH2539 - Shaft Sleeve
  • Metso LK-2017 - Actuator Linkage
  • Metso N88409030 - Hammer Screw Jaw Crusher M48X970
  • Metso 181538 - IOP365 Isolated Analog Input Module
  • Metso 10691-04 - Charging Kit Olear/Parker
  • Metso QX4SB02SDM - Automation Component
  • Metso VAL0062567 - Pneumatic Cylinder 250 Psi
  • Harkila Metso Full Zip - Fleece Jacket Willow Green
  • Metso AM1-389 829-0010-218 - Bracket for 3+4 in Ball Valve
  • Metso D200467 - IO Rack
  • Metso RKN-359XT - Repair Kit
  • Metso 2.00SB2HKT27A6 - Parker Pneumatic Cylinder
  • Metso D100306 - AIF2mV GEB Module
  • Metso A413757 - AOR4C GEB Module
  • Metso A413754 - AIR8H GEB Module
  • Metso A413767 - AOF2V GEB Module
  • Metso A413742 - BIR82 GEB Module
  • Metso A413744 - BOR82 GEB Module
  • Metso A413753 - AIR8V GEB Module
  • Metso A413752 - AIR8C GEB Module
  • Metso 96511900 - Hydraulic Filter
  • Metso IOP334 - Isolated Digital Input Module
  • Metso 1003894081 - High Flow Oil Filter Cartridge
  • Metso H035506 - Ball Valve Seat Set Kit
  • Metso PDCH2680 - Shaft Sleeve
  • Metso LK-937 - Linkage Kit
  • Metso VAL0353763 - Valmet Pneumatic Cylinder 250PSI
  • Metso APL3037188 - Hydraulic Cylinder 2" Bore
  • Metso 181540 - IOP307 Isolated Analog Input Module
  • Metso LK-2032 - Linkage Kit
  • Metso VAL0207205 - Valmet Automation Power Supply
  • Metso PDCF2680 - Shaft Sleeve
  • Metso 422244-1A - GMB Relay Module Board
  • Metso VAL0356906 - Paper Pneumatic Cylinder
  • Metso RKW-355TT - Jamesbury Repair Kit 8in
  • Metso QN2SP02SXM-BSF - Quartz Valve Control Stonel
  • Metso D201134 - AI8 Analog Input Module
  • Metso APL3032501 - Automation Component
  • Metso D201784L - MBM Backplane
  • Metso M851121 - DMU M2 Module
  • Metso A413310 - Valmet Neles VPU Power Unit
  • Sarianna Metso The Serekh Texts - Hardcover Book
  • Metso 5044i9PS - Pump Impeller
  • Metso 181575 - IOP345 Overspeed Trip Module
  • Metso RKQ-66 - Jamesbury Actuator Diaphragm
  • Metso RKW353XZ - Automation Component
  • Metso PIC-09-50-200 - Automation Component
  • Metso LK-2027 - Linkage Kit
  • Metso XZB10025-011T12 - Moog Valve 9650962700
  • Metso XZB10025-010T12 - Moog Valve 9650965300
  • Metso-SP Transmitter Cable - Operating Unit with 10m Cable
  • Harkila Metso Hybrid - Hunting Jacket Willow Green
  • Metso ND8221/S1 - Neles Valve Positioner
  • Metso METSO10119 - ScreenCheck Component
  • Metso LK-2025 - Linkage Kit
  • Metso A416733 - IQweight External Air Gap Temperature Sensor
  • Metso RKC22MT - Automation Component
  • Metso A413281 - Automation Board
  • Metso LCP9HLY - Stainless Steel Enclosure
  • Metso NP704S/B1S1 - Pneumatic Positioner with I/P Converter
  • Metso BAH3 - Slurry Seal Type
  • Metso A413531-03 - PLC Module Chassis Rack
  • Metso P4610004 - MCAI Communicator Controller
  • Metso QN2AN03HDM - Quartz Valve Positioner Stonel
  • Metso RKW-352-XZ - Automation Component
  • Metso A4300081 - Kajaani LCD Display
  • Metso A428026 7B - Kajaani Rectifier Unit 1
  • Metso 202218 - Kajaani Sensor Power Supply SR 902660
  • Metso 9150 316SS CSTL - Jamesbury 150-2" BN50 Valve
  • Metso 81806 - IOP101 Module
  • Metso STOM000272 - Paper Bushing CR38
  • Metso 1975413 - Chain Hoist Links
  • Metso IMO G053-191597 - Minor Seal Kit
  • Metso VAL0087418 - Cylinder Valmet NTS6LV
  • Metso A413061 - DMU Board VPA 420355-4B
  • Metso P2620-80/25-100 - Automation Component
  • Metso VAL0035292 - Automation Component
  • Metso A413721 - Automation Component
  • Metso ST600 - Automation Component
  • Metso P4500001 - Automation Component
  • Metso SDBX/RA2 - CAT x KVM Extender
  • Metso D201126-DI8 - Digital Input Module
  • Metso D201189L - AI8H Analog Module
  • Metso NA004418 LK1016 - Wafersphere Actuator Mounting Bracket
  • Metso RKN172MTT - Repair Kit
  • Metso MM0311584 - Air Filter Kit RadialSeal
  • Metso 181517 - IOP301 Isolated Analog Input Module
  • Metso RAU3906506 - Automation Component
  • Metso 181208 - IOP332 Digital Input Module
  • Metso A413760 - AIF2C PCB Module
  • Metso 006 1089 36 - Shaft Bearing Seal
  • Metso A413046 - Automation Component
  • Metso VKJ650 - Automation Brake Component
  • Metso LK-1875 - Linkage Kit
  • Metso D201193L - FI4S24 Frequency Input Module
  • Metso D200533 - BIU82 Binary Input Module
  • Metso 500838-M1 - Impeller Pump Release Collar Assembly
  • Metso 2.00SB2ALUS19A - Pneumatic Cylinder 1.375 Stroke
  • Metso D201351 - RES Reserve Module
  • Metso A416100 - IQMoisture Spare Part Kit Halogen Lamp
  • Metso Slurry Pump - Back Liner
  • Metso 7088010042 - Bronze Lantern Ring