K-WANG



Product Model and Configuration
1. Model of electronic cam controller
Output point NPN type PNP type
8:00 H8PR-8 H8PR-8P
16:00 H8PR-16 H8PR-16P
24:00 H8PR-24 H8PR-24P
2. Supporting components
Absolute value encoder: E6F-AB3C-C (line length 2m, can be extended up to 30m)
Connector: E69-C10B
Extension cable: E69-DF5 (5m)
Core electrical specifications
1. Power supply and power consumption
Supply voltage: AC100~240V 50/60Hz
Scope of work: 90-110% of rated value
Power consumption: approximately 10W (AC240V/50Hz)
2. Input signal
Input type specification
Encoder input dedicated E6F-AB3C-C, response 5kHz (0.2ms)
INHIBIT contact/transistor input, cut off all outputs
FORCE RUN short circuit takes effect, program modification is prohibited
3. Output signal
Output type: Open collector electrode transistor
Output voltage: 30VDC
Output current: 100mA/point
Single output: up to 10 ON/OFF cycles
Angle unit: 1 °
Starting angle: 0~359 °
4. Response time
Encoder response frequency output response time
5kHz/4kHz 0.3ms max.
3kHz 0.35ms max.
2kHz 0.5ms max.
1kHz 1.1ms max.
0.5kHz 1.5ms max.
5. Environment and reliability
Working temperature: -10~55 ℃
Humidity: 35-85% RH
Insulation resistance: 100M Ω (500VDC)
Voltage resistance: 1500VAC/1min
Memory retention: 10 years (25 ℃, battery backup)
Weight: Approximately 1.3kg
Core functions
angle control
Set the output ON/OFF angle in units of * * 1 ° * *
Single output can perform up to 10 on-off actions
Direction and Origin
Rotation direction: CW/CCW switchable
Origin compensation: -179 °~+180 °
Teaching function
Directly input the ON/OFF angle and origin position from the encoder
protection function
INHIBIT: External signal cuts off all outputs
FORCE RUN: Lock the program to prevent accidental modifications
Power down memory: battery backup, parameters not lost for 10 years

Wiring structure
1. Encoder connection
Dedicated interface, powered by the controller
The standard line length is 2m and can be extended to 30m
2. Input terminal
INHIBIT: Output input prohibited
FORCE RUN: Force Run/Program Protection
0V: Internal common terminal
3. Output terminal
NPN type: COM is the common negative pole
PNP type:+COM/- COM differentiation
RUN terminal: illuminated during operation, fault extinguished
Encoder specifications (E6F-AB3C-C)
Project parameters
Type Absolute Value Encoder
Resolution 360 (10 bits)
Power supply 5-12VDC, 100mA Max
Response frequency 10kHz
Accuracy ± 0.5 °
Maximum speed 5000rpm
Protection level IP52F
Weight approximately 500g
Installation size
Installation holes: 4 M4 screw holes
Front panel size: 192 × 96mm
24 o'clock model width: 240mm
Certification standards
UL508、CSA C22.2 No.14
EN61010-1/IEC61010-1
EMC:EN50081-2、EN50082-2
Key issues
Question 1: What are the output points of H8PR controller? How to distinguish between NPN and PNP models?
Answer: Three output specifications are available on 8/16/24; The model with P is PNP output (H8PR-8P/16P/24P), and without P is NPN output (H8PR-8/16/24).
Question 2: How many times can H8PR's single output be turned on and off at most? What is the minimum unit for angle setting?
Answer: A single output can perform up to 10 ON/OFF actions; The minimum unit for angle setting is 1 °, which can be set arbitrarily within the range of 0~359 °.
Question 3: What are the functions of the INHIBIT and FORCE RUN inputs of H8PR?
Answer: INHIBIT is used to urgently cut off all control outputs from external signals; After short circuiting, FORCED RUN enters forced operation mode, prohibiting program modification and protecting on-site parameters from accidental changes.

KONG JIANG
Add: Jimei North Road, Jimei District, Xiamen, Fujian, China
Tell:+86-15305925923