Product Overview
ULISSE UNC is a separate type of radiation safety photoelectric produced by REER, consisting of an UNCE transmitter and an UNCR receiver. It only forms a TYPE 2 safety protection system that complies with IEC 61496-1/2 when paired with an AU S3/AU S3M2/AU S-TWIN control unit. It is used for full body intrusion detection and cannot be used for hand/arm protection.
Applicable equipment: weaving machines, assembly lines, automated warehousing, robot areas, palletizing systems. Prohibited scenarios: Equipment without supporting control units, risk of object falling/spraying, and inability to shut down electrically.
Technical Parameters
Parameter item specification value
Detection distance 0.8~6 meters
Minimum detectable object 8 mm
Response time<8 ms
Supply voltage 24 Vdc ± 20%
Power consumption transmission 0.7W; reception 0.4W
Output type NPN 100mA max (Light ON)
Infrared wavelength 880 nm
Environmental light anti-interference>10000 lx
Protection level IP65
Working temperature 0~55 ℃ (no condensation, no frost)
Connector M8 3-pin
Size 15 × 25 × 63 mm
Weight 40 g
Status indicator light
Transmitting end (UNCE): Yellow light is always on=beam is normal; Extinguish=Test/No emission
Receiver (UNCR): The green light is always on, indicating that the protected area is unobstructed; Extinguish=beam obstructed
Safe distance and installation positioning
Formula for safe distance
S = 1600×(tb+tu+t1) + C
Single beam: C=1200, beam height 750mm
Dual beam: C=850, beam heights of 400mm and 900mm
Installation requirements
The transmission and reception are strictly aligned, with a distance of ≤ 6m
Stay away from strong light sources and reflective surfaces to avoid accidental triggering
Multiple systems should be placed side by side/stacked to prevent mutual interference, and the transmission should not be directed towards other receivers
Electrical connection
Interface: M8 3-pin connector, supporting up to 50m cable (≥ 1mm ²)
Power supply: PELV 24Vdc isolated power supply must be used
Key points of wiring
Pin 3 is connected to the metal casing and requires grounding or insulation treatment
Separate the power line from the power line, and ground the control unit
Test button insulation ≥ 230Vac
Support connection methods
Single/Dual Beam: AU S3/AU S3M2
Up to four beams: AU S-TWIN

Mechanical installation and calibration
Installation method: fixed bracket, with the transmitter and receiver facing each other
Calibration: Based on the stable and constant green light on the receiving end
Environment: Anti condensation, dust-proof, and high-temperature resistant
Inspection and maintenance
Daily inspection: Use 8mm opaque objects to cover the center and edges of the light beam in each shift, confirm that the receiving green light is off and the control unit is activated
Maintenance: Regularly clean the lens and prohibit the use of abrasives, solvents, and alcohol
Troubleshooting: Check wiring, alignment status, lens cleaning, and power supply voltage
Labels and ordering
Serial number: including production year/week/serial number
ordering code
Transmission+reception: 1200302
Launch UNCE: 1400302
Receive UNCR: 1500302
Key questions and answers
Question 1: Under what conditions can ULISSE UNC be used as a security device? What are the core limitations?
Answer: It must be paired with AU S3, AU S3M2, or AU S-TWIN control units to form the TYPE 2 safety system; It is strictly prohibited to use it as a personal safety protection device without a control unit. At the same time, it is only used for whole body intrusion detection and cannot be used for hand/arm protection, and the equipment must be able to immediately shut down electrically.
Question 2: What are the safe distance calculation and beam height for single beam and double beam?
answer:
Single beam: S=1600 × (total response time+machine shutdown time)+1200, beam height 750mm
Double beam: S=1600 × (total response time+machine shutdown time)+850, beam height 400mm, 900mm
Question 3: What are the daily inspection and maintenance requirements for ULISSE UNC? Which points should be prioritized for troubleshooting?
answer:
Inspection: Use 8mm opaque objects to cover the entire area of the light beam for each shift, and verify the function of turning off the receiving green light and stopping the machine
Maintenance: Regularly clean the lens and prohibit corrosive solvents
Troubleshooting: ① Wiring and power supply ② Alignment of transmission and reception ③ Lens contamination ④ Reflected light interference ⑤ Control unit status