ABB UAA326A02 HIEE300024R2
B/BE/BER 125 125 125 125Weight A/AE/AER 9 9 10 kg
B/BE/BER 20 21 21 23
Material A/AE/B/BE Stainless steel SIS 2383
DIN 17440 X12CrMoS17
Werkstoffnr 1.4104
AISI 430F
AER/BER Acid resistant steel:
DIN 17440 X2CrNiMo17 13 2
Werkstoffnr 1.4404
AISI 316L
Accuracy
Accuracy class A/AE/AER
B/BE/BER
± 0,5 %
Linearity deviation < ± 0,3
Repeatability error < ± 0,05
Hysteresis <0,2
Compensated temperature range
+20 - +80 °C
Zero point drift 30 (80 2)) ppm/K
Sensitivity drift 150
Working temperature
range
-10 - +105 °C
Zero point drift 50 (100 1)) ppm/K
Sensitivity drift 250
Storage temperature
range
-40 - +105 °C
1) #efinitions of directions designations “V
”and “A” in FV
and FA are given in 2.5.1 Coordinate System.
2) PFTL 101AER -0.5 kN/ -1.0 kN

Accuracy and Accuracy Class
Accuracy class is defined as the maximum deviation, and is expressed as a percentage of the sen sitivity at nominal load.
This includes linearity deviation, hysteresis and repeatability error.
Linearity Deviation
Linearity deviation is the maximum deviation from a straight line drawn between the output values
at zero load and nominal load. Linearity deviation is related to the sensitivity.
Signal
Force Fnom
Figure 6. Linearity Deviation
Hysteresis
Hysteresis is the maximum difference in the output signal at the same load during a cycle from zero
load to nominal load and back to zero load, related to the sensitivity at nominal load. The hysteresis
of a Pressductor transducer is proportional to the load cycle.
Repeatability error
Repeatability error is defined as the maximum deviation between repeated readings under identical
conditions. It is expressed as a percentage of the sensitivity at nominal load.
Compensated temperature range
The temperature drifts of the load cell have been compensated for in certain temperature
ranges. That is the temperature range within which the specified permitted temperature drifts (i.e.
zero point and sensitivity drifts) of the load cell are maintained.