ABB UAD215A101 3BHE026284R0101 PEC80 converter signal board
Options
To meet certain special application requirements
the following options are available:
Insulation amplifier PXUB 201
The insulation amplifier can be used when galvanic
insulation is required for analog output signals.
The insulation amplifier can be connected to all
versions and PFEA 113 – IP 65 can hold up to four
PXUB 201.
Options and dimensions
Supply voltage 24 V (20 to 253 V AC/DC)
Current consumption 10 mA + external load
Signal range Input Output
0 to ±10 V 0 to ±10 V
0 to ±10 V 0 to ±20 mA
0 to 10 V 4 to 20 mA
Rated insulation voltage 600 V (basic)
Relay board PXKB 201
PXKB 201 is DIN-rail mounted and can be mounted
in the IP 65 versions of the Tension Electronics
together with the insulation amplifier. PFEA 113-65
can hold up to four PXKB 201.
Supply voltage 24 V DC
Power consumption 18 mA
Contact data AC 6 A at 250 V
DC 6 A at 250 V
Power supply unit
When using the DIN-rail IP 20 version of the
electronics and 24 V main supply is not available,
ABB offers optional power supply units.
The compact units transform main supply from
110 to 120 V/207 to 240 V AC to 24 V DC for supply
of the PFEA 111, 112 and 113.
Three power supply units with different power
ratings are available. The table below indicates max.
number of electronics per power supply unit.
PFEA 111 PFEA 112 PFEA 113
SD831 3 A 6 6 3*
SD832 5 A 12 12 6*
SD832 10 A 24 24 12*
* Supply of digital outputs are not included

Data PFEA 111 PFEA 112 PFEA 113
Power supply
IP 20 voltage 24 V DC (18 to 36 V)
Power requirement 7.5 W 7.5 W 12 W
IP 65 main voltage 24 V DC (18 to 36 V), 100 (–15 %) to 240 (+10 %) V AC
Frequency 45 to 65 Hz
Number of load cells 2 2 4
Load cell excitation
Current 0.5 A RMS, 330 Hz 0.5 A RMS, 330 Hz 0.5 A RMS, 330 Hz
Max. load 2 load cells
plus 5 Ω cable resistance
2 load cells
plus 5 Ω cable resistance
4 load cells
plus 10 Ω cable resistance
Inputs
Digital inputs (remote zero
or gain scheduling) — — 1
Analog inputs (connection
of multiple PFEA 113 units) — — 2
Outputs
Analog outputs (voltage or current) — — 6
–5 to 11 V (max.load 5 mA) 1 1 —
0 to 21 mA (max. load 550 Ω) 1 1 —
Selectable filter
Step response (0 to 90 %) can be
set for each output 15, 30, 75, 250, 750, 1500 ms 15, 30, 75, 250, 750, 1500 ms 5, 15, 30, 75, 250, 750, 1500 ms
Scaling function of analog outputs Yes Yes Yes
Digital outputs
(Status OK and/or Level detectors) — — 4
Self diagnostics, Status OK
LED (green/red) Yes Yes Yes
Alarm on Digital output — — Yes
Alarm via Profibus — Yes Yes
Multi-language interactive display 1 Yes Yes Yes
Selectable tension units
on the display N, kN, kg and Ibs, N/m, kN/m, kg/m, pli
Maximum load memory Yes Yes Yes
Zero offset memory Yes Yes Yes
Communication
ProfiBus DP, baud rate
up to 12 Mbit — Yes Yes
GSD-file — ABB_0716.GSD ABB_0717.GSD
Environmental tolerance
Electrical environment
Electrical interference environment As per EMC Directive 2014/30/EU
Electrical safety As per Low Voltage Directive 2014/35/EU
As per UL508 Industrial control equipment 2
Ambient temperature 5 to 55 °C
Degree of protection IEC 529 Protection class IP 20 or IP 65