Kollmorgen SERVOSTAR ® CD series digital servo motor amplifier

From: | Author:Wang | Time :2026-02-10 | 117 visit: | 🔊 Click to read aloud ❚❚ | Share:


Kollmorgen SERVOSTAR ®  CD series digital servo motor amplifier

Kollmorgen SERVOSTAR ®  The installation and operation guide for the CD series digital servo motor amplifier (divided into Series 2/5, supporting 3/6/10A continuous current) is designed to adapt to industrial motion control scenarios. It supports three control modes: current/torque, speed, and position, and is compatible with three types of feedback devices: rotary transformers, incremental encoders, and sine encoders. It has RS-232/RS-485 serial port and SERCOS fiber communication capabilities, and is configured and monitored with MOTIONLINK software. The operating temperature ranges from 5 ° C to 45 ° C, with a protection level of IP20. The manual provides detailed product parameters, installation wiring, communication configuration, system operation, fault diagnosis, and firmware upgrades throughout the entire process. It also includes motor wiring diagrams, encoder type instructions, and other appendices to ensure safe and stable equipment operation.


Manual and Product Basic Information

Product positioning and series differentiation

Core attributes: Digital servo motor amplifier, suitable for industrial motion control scenarios such as machine tools, packaging, electronic assembly, etc

Series versions: Series 2 (model number 5 is 2, such as CR06250), Series 5 (model number 5 is 5, such as CR06550), Series 5 is an upgraded version that is compatible with the form and functions of Series 2, with new features such as DSP control and extended I/O

Model code: Cx zz 5yw (C=CD series, zz=continuous current: 03/06/10A, 5=logic power supply, y=feedback type: E=encoder/B=sine encoder/R=rotary transformer, w=control interface: 0=analog/1=SERCOS/4=DeviceNet)

Core hardware specifications | Specification categories | Key parameters|

|Current output | Continuous current: 3A (Cx03)/6A (Cx06)/10A (Cx10); Peak current: up to 26A (500ms)|

|Power input | Voltage: 115VAC (single-phase/three-phase), 230VAC (single-phase/three-phase); Frequency: 47-63Hz|

|Physical dimensions | Cx03: 67.3 × 163.0 × 36.6mm; Cx06: 83.3 × 216.0 × 33.7mm; Cx10: 99.1 × 244.0 × 33.7mm|

|Weight | Cx03: 3.56lbs (1.61kg); Cx06:4.9lbs(2.22kg); Cx10:5.94lbs(2.69kg) |

|Environmental requirements | Operating temperature: 5 ° C~45 ° C; Storage temperature: 0 ° C~70 ° C; Humidity: 10% -90% (no condensation); Protection level IP20|

Core control performance | Control loop | Update rate | Bandwidth | Resolution/accuracy related|

|Current loop | 16kHz (62.5 μ s) |<2400Hz | Suitable for three-phase motors, PWM frequency 8/16kHz | Speed loop | 4kHz (250 μ s) |<400Hz | Serial command resolution 1rpm, long-term stable speed accuracy 0.01%|

|Position ring | 2kHz (500 μ s) | - | Encoder input up to 3MHz, supports electronic gear function|


Installation and wiring specifications

Installation requirements

Installation method: NS 35/7.5 EN 50022 standard DIN rail installation, metal panel grounding (to ensure electromagnetic compatibility)

Heat dissipation spacing: Side to side spacing ≥ 12.7mm (0.5in), top to bottom spacing ≥ 63.5mm (2.5in)

Cabinet requirements: Metal shielded cabinet, maintain ventilation, avoid environmental temperature exceeding 45 ° C

Core wiring specifications

Cable separation: The distance between power lines (motor lines, power lines) and signal lines (feedback lines, I/O lines) is ≥ 20cm (8in), and they intersect at a 90 ° angle

Grounding requirements: Single point star grounding is used, and flat braided wire or copper bar is used for high-frequency grounding to avoid ordinary wires (excessive inductance)

Shielding treatment: Motor wires and feedback wires need to be shielded at both ends, and the shielding layer should be laid flat and grounded at the entrance of the cabinet. It is recommended to use Phoenix Contact shielding clips (such as SK8/SK14/SK20)

Key interfaces:

Power interface: L1/L2/L3 (three-phase input), GND (ground), B+/C (regenerative resistor)

Motor interface: MA/MB/MC (motor three-phase)

Feedback interface: C2 (motor feedback), C8 (remote encoder input)

I/O interface: C3 (user I/O, including analog input/output, fault relay, remote enable)

Communication interface: C1 (RS-232/RS-485), SERCOS port (fiber Tx/Rx, optional)

EMC Compliance Configuration

Input power filtering: An EMI filter (such as Cx03 adapted Filter Concepts SF7) needs to be configured and installed near the power entrance of the cabinet

Motor line filtering: Long cables need to be equipped with common mode chokes (such as Fair Rite 2643665702) to avoid high-frequency interference

I/O line filtering: 24V power line, remote enable line need to be equipped with ferrite core (such as Fair Rite 2643167251)

Communication and software configuration

Communication mode configuration

Serial communication (RS-232/RS-485):

Baud rate: 9600/19200bps (set through DIP switch 6)

Address setting: DIP switches 1-5 are used to set multiple machine addresses (0-31), with address 0 indicating single device mode

Connection method: RS-232 supports point-to-point connection, RS-485 supports multi machine cascading (up to 31 units)

SERCOS fiber optic communication (optional):

Transmission rate: 2M/4Mbps (DIP switch 6 setting)

Address setting: DIP switches 1-5 are used to set the address (0-31), with 0 indicating repeater mode

Cable requirements: 1mm plastic optical fiber, attenuation ≤ 0.18dBm/m, maximum transmission distance 71.4m (high-power mode)

MOTIONLINK software features

Core functions: device configuration, motor parameter loading, control mode selection, automatic tuning, real-time monitoring, fault viewing

Operation process:

Install software (requires Windows system, 16MB RAM)

Connect devices through serial port

Complete motor configuration, control mode selection, and parameter tuning using Startup Wizard

Save parameters to EEPROM or SSV file (for backup/recovery)

Advanced features: direct command sending in terminal mode, oscilloscope function to record motion curves, batch configuration of multiple devices


System operation and control

Detailed explanation of control mode

Current/torque mode (OPMODE 2/3): receives ± 10V analog signals or serial T commands, current loop bandwidth<2400Hz, supports torque compensation

Speed mode (OPMODE 0/1): Receive ± 10V analog signals, serial J commands or I/O triggers, speed range 0~VLIM (configurable), supports S-curve acceleration and deceleration

Position mode (OPMODE 4/8): Supports electronic gears, pulse/direction counting, encoder tracking, positioning accuracy depends on feedback devices, supports zero return function

Key operational processes

Power on self-test: After the device is powered on, a self-test is performed, and the status display flashes. After all segment codes are displayed, the running mode (0-8) is displayed

System enablement: Must meet ACTION=READY × REMOTE × DIPEN, READY=DRIVE OK × SWEN (no fault+software enablement)

Feedback calibration: The sine encoder needs to perform SINInitiat calibration, and the rotary transformer achieves high-precision sampling through software RDC conversion

protection function

FoldBack protection: The exponential decay of current to continuous current value (ICONT) starts 1/2 second after driving overload

Motor thermal protection: Monitor the motor thermoelectric signal through THERM variable, display "H" and disable when overheating occurs

Other protections: overvoltage (430VDC trip), undervoltage (90VDC trip), overcurrent, overtemperature (80 ° C trip)


Troubleshooting and Maintenance

Classification and Handling of Fault Codes

Fatal malfunction (such as Err1: power level overheating, displaying "t"): Power off and restart are required to investigate heat dissipation or load

Non fatal faults (such as Err20: unknown command): can be cleared through software and the command format can be checked

No message fault (such as hardware limit triggering, displaying "L"): I/O wiring or limit switch status needs to be checked

Common troubleshooting tools

MOTIONLINK status screen: View fault history (FLTHIST), device status (Status)

I/O screen: Check the output status of limit switches, thermostats, and encoders

Monitoring screen: Compare parameters such as current (I/IA/IC), speed (V/VCMD), position (PFB/PE), etc

Maintenance and Upgrade

Daily maintenance: maintenance free, use dry and lint free cloth for cleaning, prohibit the use of cleaning agents

Firmware upgrade: Download the firmware (. emb file) through the RS-232 port using the Ignite. exe tool, and restart the device after the upgrade

Repair restrictions: Only manufacturers or authorized engineers can repair, unauthorized repairs may void the warranty

  • Metso XZB10025-011T12 - Moog Valve 9650962700
  • Metso XZB10025-010T12 - Moog Valve 9650965300
  • Metso-SP Transmitter Cable - Operating Unit with 10m Cable
  • Harkila Metso Hybrid - Hunting Jacket Willow Green
  • Metso ND8221/S1 - Neles Valve Positioner
  • Metso METSO10119 - ScreenCheck Component
  • Metso LK-2025 - Linkage Kit
  • Metso A416733 - IQweight External Air Gap Temperature Sensor
  • Metso RKC22MT - Automation Component
  • Metso A413281 - Automation Board
  • Metso LCP9HLY - Stainless Steel Enclosure
  • Metso NP704S/B1S1 - Pneumatic Positioner with I/P Converter
  • Metso BAH3 - Slurry Seal Type
  • Metso A413531-03 - PLC Module Chassis Rack
  • Metso P4610004 - MCAI Communicator Controller
  • Metso QN2AN03HDM - Quartz Valve Positioner Stonel
  • Metso RKW-352-XZ - Automation Component
  • Metso A4300081 - Kajaani LCD Display
  • Metso A428026 7B - Kajaani Rectifier Unit 1
  • Metso 202218 - Kajaani Sensor Power Supply SR 902660
  • Metso 9150 316SS CSTL - Jamesbury 150-2" BN50 Valve
  • Metso 81806 - IOP101 Module
  • Metso STOM000272 - Paper Bushing CR38
  • Metso 1975413 - Chain Hoist Links
  • Metso IMO G053-191597 - Minor Seal Kit
  • Metso VAL0087418 - Cylinder Valmet NTS6LV
  • Metso A413061 - DMU Board VPA 420355-4B
  • Metso P2620-80/25-100 - Automation Component
  • Metso VAL0035292 - Automation Component
  • Metso A413721 - Automation Component
  • Metso ST600 - Automation Component
  • Metso P4500001 - Automation Component
  • Metso SDBX/RA2 - CAT x KVM Extender
  • Metso D201126-DI8 - Digital Input Module
  • Metso D201189L - AI8H Analog Module
  • Metso NA004418 LK1016 - Wafersphere Actuator Mounting Bracket
  • Metso RKN172MTT - Repair Kit
  • Metso MM0311584 - Air Filter Kit RadialSeal
  • Metso 181517 - IOP301 Isolated Analog Input Module
  • Metso RAU3906506 - Automation Component
  • Metso 181208 - IOP332 Digital Input Module
  • Metso A413760 - AIF2C PCB Module
  • Metso 006 1089 36 - Shaft Bearing Seal
  • Metso A413046 - Automation Component
  • Metso VKJ650 - Automation Brake Component
  • Metso LK-1875 - Linkage Kit
  • Metso D201193L - FI4S24 Frequency Input Module
  • Metso D200533 - BIU82 Binary Input Module
  • Metso 500838-M1 - Impeller Pump Release Collar Assembly
  • Metso 2.00SB2ALUS19A - Pneumatic Cylinder 1.375 Stroke
  • Metso D201351 - RES Reserve Module
  • Metso A416100 - IQMoisture Spare Part Kit Halogen Lamp
  • Metso Slurry Pump - Back Liner
  • Metso 7088010042 - Bronze Lantern Ring
  • Metso IMC-101-M-SC - Industrial Media Converter
  • Voith S1-S1-CAM-ENCL - Metso Pump Cmare Housing & Bracket
  • Metso A4430726V1.1 - Kajaani Connection Box CI 4-9-10
  • Metso A413016 - NCU2 PLC Board
  • Metso D202213P - MBMT80 Base
  • Metso A413135 - AOU-4 Analog Output Board
  • Metso NP 724A - Pneumatic Valve Positioner
  • Metso A413246 - Automation Controller Module
  • Konaflex VKJ-650 - Disc Brake Set Pair
  • Metso WIN3096535D - Core Chuck
  • Metso D201380 - MBR Base with IBC & IPS
  • Metso D202213L - MBMT80 Base Module
  • Metso 181571 - IOP337 PLC Module
  • Metso MF0588336 - Main Hydraulic Filter
  • Metso 181504 - IOP303 RTD Input Module
  • Metso A413240 - PIC2 Board
  • Denver 566534PS - Case Liner Gland Side SRL Frame 2
  • Metso 181508 - IOP322 Digital Input Module 120V
  • Metso 181520 - IOP351 Relay Output Module Form A/B
  • Metso 181220 - IOP351 Relay Output Module
  • Metso A413150 - BOU 8 Binary Output Module
  • Metso 128400-M1 - Impeller
  • Metso D201379 - MBB Base with IBC & IPS
  • Metso 205181 - T/B MTD PRWSW Assembly
  • Metso QPX1C/K15 - Jamesbury Quadra-Powr X Actuator Valve
  • Harkila Metso Winter - Hunting Jacket Willow Green
  • Metso NE724A/A-L - Electro-Pneumatic Positioner
  • Metso PACP-100-80-31 916 - Automation Component
  • Metso 81814 - Automation Component
  • Metso ER-12-01-M-CT - Automation Board
  • Metso ELO24 - Automation Board
  • Metso A413000 - Valmet Neles CPU PLC Board
  • Metso XL-2213-0525 - Mainframe Bushing
  • Metso D100097 - ECR Extension Module
  • Metso 804511 - Filter Housing Assembly
  • Metso S420154 - Automation Rack Chassis
  • Metso M851232 - Automation Module
  • Metso D100532 02 - Automation Board
  • Neles QPX1C/M - Ball Valve with Quadra-Powr X Actuator
  • Metso 181535 - IOP322 Isolated Analog Output Module
  • Metso RKN-184-XTZ - Ball Valve Seat Repair Kit 4"
  • Metso N22022621 - Metal Plate
  • Metso 181560 - IOP341 Positioner Module
  • Metso LT 1213 S - Filter Service Kit for CAT C12 Engine
  • Aq-Matic 0032-99000 - Valve Diaphragm
  • Metso D200535 - BOU8 Output Board
  • Metso EDS-305-M-SC - Ethernet Switch
  • Metso 80424 - IOP110 Analog Output Module
  • Metso IOP351 - Relay Output Module Form A/B
  • Metso 181572 - IOP342 Module
  • Metso 1-1-2A3600TT - Ball Valve 1.5"
  • Metso A413154 - BOU8-4 Output Module
  • Metso A413140 - Valmet BIU 8 Board
  • Metso D201139 - IPS Power Supply type DDC7940
  • Metso PGH P411382-2000 - Metal Feed/Filtrate Hose
  • Valmet 503201404 - Automation Board
  • Metso 181507 - IOP331 Controller Module
  • Metso A413141 - BIU82 Binary Input Module
  • Metso KSD7447686 - Pneumatic Cylinder 5" Bore
  • Metso APL3003850 - Automation Component
  • Metso D201135L - Automation Controller
  • Metso A413125 - AIU8 Analog Input Module
  • Metso A413325 - IPU Power Unit
  • Metso 181573 - IOP346 PLC Module
  • Metso A413143 - BIU84 Binary Output Module Card
  • Metso A413152 - BOU82 Output Module
  • Metso PDP603 - Distributed Processing Unit 181555
  • Metso PDP601 - Distributed Processing Unit 181555
  • Metso A413040 - DCS Board DCU
  • Metso A413082 - CPU Processor Module
  • Valmet TI4W3 - Temperature Input Module
  • Valmet FI4S24 - Frequency Input Module
  • Metso 1064669615 - Fulcrum Bar
  • Valmet 181206 - IOP330 Digital Input Module