Siemens SIRIUS 3SK2 safety relay

From: | Author:Wang | Time :2026-06-03 | 7 visit: | 🔊 Click to read aloud ❚❚ | Share:


Siemens SIRIUS 3SK2 safety relay

General Principles of Basic Information and Security

Applicable products: 2 body types (22.5mm narrow type 3SK2112, 45mm wide type 3SK2122, screw terminal/spring plug terminal)+3SK26 local display+3RK35 DP bus module, can be matched with 3SK1 output expansion and 3RM1 safety motor starter; Supporting configuration software Safety ES.

Safety classification: Meets EN62061 (SIL3), EN ISO13849-1 (PL e/CAT4), and can achieve Class 0/Class 1 shutdown standards.

Warning classification: The document is divided into four levels of warnings: DANGER, Warning, CAUTION, and NOTICE. Live working must be powered off and locked, and unauthorized bypassing of safety circuits is prohibited; External independent power supply is strictly prohibited for 3SK1/3RM1, and power can only be supplied from 3SK2 through the 3ZY12 connector.

Supporting resources: Siemens Industrial Online Support, Product Selection and Configuration Tool, Security Level Assessment Tool; The DataMatrix QR code for the device casing can be quickly accessed through the official app for information.

Responsibility statement: The safety design of the entire equipment is the responsibility of the equipment manufacturer, and Siemens does not assume responsibility for the overall design of the equipment.


Product Hardware and Function Introduction

1. Hardware differences between two 3SK2 models

Project 22.5mm model 45mm model

Safe input 10 points (5 sets of dual channels) 20 points (10 sets of dual channels)

Safe solid-state output with 2 channels and 4 channels

Ordinary non safety output 1 channel and 2 channels

Test power supply 1 group T1/T2 2 groups isolation T1_1/T2_1, T1_2/T2

Comes with a built-in display screen without a local button display screen

External storage without removable encrypted storage module (storage configuration)

Shared configuration: The rear SYS interface is equipped with external expansion devices through the 3ZY12 connector, with reserved system communication port X1 and panel RESET reset button (fault reset/factory reset).

2. Introduction to Supporting Accessories

3SK26 diagnostic panel: cabinet door opening installation (opening 92 × 55mm), IP54 front protection, text display fault, supports external PC, cable length up to 2.5m, can be disconnected from PC for on-site fault diagnosis.

3RK35 DP module: PROFIBUS-DP slave station, maximum speed of 12Mbps, bidirectional 32/64bit process data exchange, panel LCD can set DP address, restore factory, realize data exchange between upper PLC and safety relay.

3SK1 output expansion: divided into 22.5mm (up to 5) and 90mm (only 1 and at the end), with two secure outputs bound to the main body through dialing, used for high-capacity load expansion.

3RM1 safety motor starter: direct start/forward/reverse model, with built-in fault monitoring on the body, controlled through a connector, used for motor safety cut-off.

3. Built in logic function library (Safety ES software configuration)

Monitoring functions: emergency stop, safety door, safety carpet, two handed operation (IIIc level), grating ESPE, mode switch, door with lock, etc;

Logic components: AND/OR/XOR/NOR, SR flip-flop, counter, various delays (power on/off delay);

Startup mode: automatic startup, manual startup, monitored startup (emergency stop must use controlled startup to meet PLe);

Industry standard safety features such as muting, timing monitoring, discontinuity channel deviation detection, and circuit cross short circuit detection.

4. Definition of Key Safety Terms

Dual channel redundancy: essential for achieving PL e, with no loss of safety function at a single point of failure;

Cross circuit detection: Using a variable frequency test power supply, detect cable short circuits, broken skin parallel connections, and can be turned off as needed;

Light/Dark Test: Output periodic short-term on/off self-test to determine output short circuit/open circuit. It can be turned off during delayed output, which will reduce diagnostic coverage;

Shutdown category: Cat0 immediate power-off shutdown, Cat1 delayed controlled shutdown.


Installation specifications

Installation methods: DIN35 rail buckle installation and flat screw fixation; 3SK1213、 The diagnostic panel and DP module have installation tilt angle restrictions.

System layout rules (from left to right): Diagnostic panel → DP module → 3SK2 body → 3SK1/3RM extension (up to 5, 90mm 3SK1 must be placed at the far right end of the entire string), with terminal connectors at the end.

Environmental parameters: altitude ≤ 2000m; ambient temperature varies with configuration and output power, with a maximum temperature of 60 ℃ for a single machine and 40 ℃ for multiple devices with DP/full load, requiring reserved heat dissipation gaps.

3ZY12 connector: the core component of the whole machine interconnection, divided into direct and terminal types. The 3SK1 on the terminal has a dial code, and the 3RM has no dial code.

Wiring specifications

Power supply requirements: The whole machine is powered by DC24V SELV/PELV safety ultra-low voltage, and the sensors and DP modules are supplied with the same power supply. All FE functional grounding terminals are short circuited and shielded in accordance with the specifications.

Terminal type: screw terminal (torque 0.6~0.8Nm), spring plug terminal; Distinguish the appropriate wire diameter for single/multi strand cables, and clarify the wiring requirements for different wire specifications.

Safe input wiring

Connect the dual channel sensor to the corresponding T1/T2 test power supply, enable cross short circuit detection, and meet SIL3/PLE requirements;

Passive electronic sensors (gratings, etc.) cannot be connected to the test power supply and cross line detection needs to be turned off.

Safe output wiring: Single channel wiring requires cable protection inside the cabinet to avoid short circuits, and high safety levels must have dual channel separate wiring; Inductive loads require parallel absorption circuits to prevent surge damage to the output.

Wiring of external components: 3SK1 and 3RM can only obtain electrical control signals through the SYS connector on the back. External power supply for A1/A2 is prohibited, otherwise the safety circuit will fail.

Communication wiring: The DP bus follows the PROFIBUS specification, and the terminal resistors at the beginning and end are turned on as needed. Dust plugs must be installed when the system interface is idle.


Equipment operation

3SK body: narrow type with only RESET key; Wide multiple SET/MODE buttons, used for browsing menus and viewing status on the local display screen.

3SK26 panel: Up, down, left, right+soft buttons, can switch between faults, system parameters, display settings (language/contrast/backlight duration).

DP module: SET+MODE button, menu can modify DP address (1-126), restore to factory; Lockable address modification permissions to prevent tampering.

Three operating modes

Configuration mode (yellow light): No valid program, Safety ES configuration can be downloaded;

Test mode (green light flashing): PC online forced positioning, debugging, on-site isolation of equipment to prevent misoperation;

Safe operation (constant green light): Formal production, all safety logic takes effect.


System Planning and Configuration Design

Hardware quantity limit: A single system can only have one 3SK2, with a total of ≤ 5 expansion components (3SK1+3RM).

Key points of Safety ES configuration: graphical drag and drop programming, capable of logic verification, program download, online monitoring, and supporting output forced debugging; The program cycle can be set to 10~60ms, with a fixed DP of 15ms.

Response time calculation formula: distinguish between three types of calculation formulas: normal response, single channel fault response, and dual channel fault, including sensor, input sampling, cycle, timer, output, and actuator delay. It is used for equipment safety distance calculation during selection.

Output light dark test parameter configuration: The regular output dark test is fixed at 3ms, and the delay output can be adjusted from 3 to 400ms. The parameters directly affect the fault response time and the upper limit of capacitive load.

Sensor/actuator selection: The shortest conduction time of the sensor is ≥ 2 times the program cycle; The action time of contactors and other actuators should be greater than the light test pulse to avoid misoperation.

DP configuration: Import GSD files into STEP7, which can be set with read and write permissions and password locking to prevent unauthorized rewriting of security programs by the upper level; After the bus is disconnected, the safety relay automatically uses a substitute value of 0 to maintain a safe state.


Maintenance and replacement of spare parts

Factory restoration: Power off and press RESET to power on, operate according to the indicator light sequence, clear internal configuration, and restore DP address to 126; The 45mm model synchronously clears the storage module.

Spare parts replacement: power off the entire circuit before replacement; The 22.5mm model should be backed up with software in advance, and the 45mm model should be configured by directly unplugging the storage module for reuse; After the replacement is completed, the entire system wiring and configuration will be tested item by item for functionality.

Regular annual inspection: SIL3 circuit contactor actuator components are subject to mandatory shutdown testing every year, while SIL2 undergoes differentiated testing as needed every year/month.


Multi level fault diagnosis scheme (5 diagnostic approaches)

Body LED diagnosis: Device (running), SF (group fault), BF (bus fault) three color lights, different flashes represent equipment faults, logic errors, and wiring abnormalities.

The 45mm model comes with a built-in screen: divided into input, output, and fault menus, with a single point display of 0/1/fault status.

External 3SK26 text panel: Layered menu (Fault/Status/System Configuration/Display Settings), allowing you to view specific point fault types (such as cross line, contact adhesion, startup abnormality, etc.).

PC+Safety ES: Online real-time monitoring, fault logs with timestamps.

PROFIBUS bus diagnosis: PLC reads fault codes from the DS0/DS1/DS92 dataset, and the manual defines various fault numbers and disposal plans, including hardware, configuration, bus, and wiring faults.


Key technical parameters

Safety indicators: SIL3, PLe/CAT4, SFF=99%, DCavg=99%, T1 service life of 20 years;

Electrical: DC24V power supply, safe output single channel maximum 4A, environment -25 ℃~+60 ℃;

Mechanical: DIN rail installation, protection IP20;

Wire diameter: screw terminal 0.5~2.5mm ², spring terminal 0.5~1.5mm ².


Drawings and accessories

Including product dimensions, opening drawings, and internal schematics; List the complete range of spare parts, connector models, and terminal accessories.


Application examples (core practical content of the manual)

The manual includes dozens of classic industrial safety wiring cases, covering:

Safe input: emergency stop of different levels (SIL1~SIL3), safety door (mechanical/electronic switch), 2/4 type safety light barrier, safety carpet, manual operation;

Safe output: contactor Cat0/Cat1 cut-off, 3SK1 extended drive, 3RM motor safe shutdown, frequency converter safe control;

Complex working conditions: Shielding Muting, Keyed Safety Doors, Multiple 3SK Cascades, Single/Dual Channel Hybrid Solution, covering mainstream safety design scenarios for machine tools and automated assembly lines.

  • LTI Drives CDF30.002.C0.7 Compact Servo Controller 08685963 DC 24V Industrial Module
  • LUST LTI Drives CDB32.008.W2.4.BR.PC1 Servo Drive Industrial Motion System
  • LUST LTI Drives CDB34.003.C2.4.PC1.H15 Servo Motor Driver Industrial Control Unit
  • LUST LTI Drives CDA32.004.C1.4.H08.B0 Servo Drive Mat. 3084456 Industrial Control
  • LUST LTI Drives CDE34.005.W2.2 Industrial Servo Drive Motion Control Unit
  • LUST LTI Drives CDA34.006.W3.0 Servo Drive Software V3.70-04 Industrial Controller
  • LTI Drives CDB32.004.C2.4.SH Servo Drive Compact Motion Controller
  • Woodward 9905-373 - Digital Synchronizer And Load Controller
  • WOODWARD MAGNETIC PICKUPS - Sensor
  • WOODWARD GCP-30 - Steuertafel for Industrial Regulator Genset Control Package
  • WOODWARD GOVERNOR 9907-1183 REV A - 505 ENHANCED TURBINE CONTROL
  • WOODWARD 9907-173 REV B - Module Load Sharing 120 Volt
  • WOODWARD 9907-014 - 2301A controller
  • Woodward 9905-029 - SPM-A Synchronizer Module Rev C
  • WOODWARD 8440-1799 EASYGEN-350 REV B - Genset Controller
  • WOODWARD 5466-258 REV M - SIMPLEX DISCRETE I/O MODULE
  • Woodward 8440-1884 C - Controller Easygen 2500-5
  • Woodward 8441-1153 - Monitoring Unit 250VAC
  • WOODWARD 8406-120 REV G - EGCP-2 DIGITAL CONTROL
  • Woodward 8273-584 - Atlas-ii Digital Control
  • Woodward 8272-582 - APM Motor Control 8272582
  • Woodward 9905-377 Rev. A - 2301A Load Sharing and Speed Control
  • WOODWARD 8272-517 - Pm Motor Control
  • WOODWARD 9905-797 REV.B - DIGITAL SYNCHRONIZER AND LOAD CONTROL DSLC-D
  • WOODWARD 8272-582 - APM MOTOR CONTROL
  • Woodward Seg FP2-8-24 - Emergency Power Telecommunications Module NP2
  • WOODWARD 2001-12E2U1B1S1A - Fuel Shut Off Valve Stop Solenoid Valve 2000-4505
  • Woodward 8440-1884 K - Genset Controller Easygen-2500-5
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 8404-009 - Proact Digital Plus Front Panel Rev. H
  • Woodward 8271-651 - Digital Speed Reference
  • Woodward 3077-474C - 8605895 5501-031 D Circuit Module
  • WOODWARD 5466-257 REV.-C - NETCON 5000 MODEL REMOTE TRANSCEIVER I/O MODULE
  • Woodward 8273-101 Rev: A - 2301D Digital Load Sharing and Speed Control
  • WOODWARD 8272-799 - 2301A SPEED CONTROL WITH REMOTE REFERENCE REV:C
  • Woodward 8272-517 - PM Motor Control
  • Woodward 8290-048 8290048 Rev. F - Generator Load Sensor
  • woodward 8273-1012 rev c - 2301e Load Sharing and Speed Control
  • WOODWARD 9905-797 - DIGITAL SYNCHRONIZER AND LOAD CONTROL FOR 3 PHASE GENERATORS
  • WOODWARD 8280-3014 - 723 PLUS DIGITAL CONTROL REV NEW
  • WOODWARD 8440-1884 REV G - GENSET CONTROLLER EASYGEN-2500-5/P1
  • Woodward 8272-683 K - Digital Reference
  • WOODWARD 9907-014 - SPEED CONTROL 2301A REV H
  • Woodward Type UG-8 P/N 037260 - Governor R.P.M 1075-1650 Motor KM58-20
  • WOODWARD 9905-970 - LINKNET 6 CHANNEL 100 OHM RTD Rev:J
  • Woodward 9907-1183 Rev C - Steam Turbine Digital SCREEN 505E Turbine Control
  • Woodward 8440-1614 - GCP-30 Genset Control Package, Rev: F, Type 1, E231544
  • Woodward DC11006-304-024 - ACTUOTOR DYNA ACTUATOR - BARBER-COLMAN
  • Woodward 9905-971 - LINKNET 6 CHANNEL 100 OHM RTD Rev:K
  • Woodward DYNK-10249 - Actuator Controller Kit - DYNA 2000
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV F
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. G Gererator Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 8440-2080 - EASYGEN 2000 genset controller EASYGEN-2300-5/P1
  • Woodward 505DE - Digital Control System
  • Woodward 701 - Digital Speed Control 18-40 VDC 4-20 MA
  • Woodward 8440-1799 - EASYGEN-350 REV B
  • Woodward 8272-582 - Apm Motor Control 100-220v AC/DC
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward XD1-T - XD1T55SAT TRANSFORMER DIFFERENTIAL PROTECTION RELAY
  • Woodward 8272-517 - PM Motor Control 220vac
  • Woodward 8934-658 - Repair Kit UG8D Governor
  • Woodward 5437 18 - module netcon derivative analog rev.A
  • Woodward 8272-171 A - Pm Motor Control
  • Woodward MRN3-1/2 - SEG mains uncoupling relay MRN314D mains decoupling relay
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5431-640 C - Dual Dynamics 1000 Series Speed Control Module
  • Woodward 5501-031 D - 3077-474C 8605895 Circuit Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward NC3-2-8 (NO) - GENERATOR CONTROLLER
  • Woodward 8271-467 K - 2301 LOAD SHARING AND SPEED CONTROL PART NO:
  • Woodward 8440-2177 A - SPM-D2-10 Digital Synchronising Controller
  • Woodward LXMG1614E-14-11 - CCFL and UV Lamps Inverter Module
  • Woodward 8270-990 - signal converter
  • Woodward 9905-068 - LOW VOLTAGE 2301A LOAD SHARING & SPEED CONTOL P/N:
  • Woodward 8901-051 - BOOSTER SERVOMOTOR, SINGLE CYLINDER, 2:1
  • Woodward 8444-1024 D - MWS4-55M CONTROL MODULE UNIT
  • Woodward 5448-914 - GCP-20 Genset Control GCP-20 REV D P/n:
  • Danfoss BHA-1 018-1942 - Hydraulic Actuator
  • Woodward 9905-001 L - SPM-A SYNCHRONIZER
  • Woodward 5464-850 - Module
  • Woodward 5501-371 - Micronet Simplex Mpu Aio Rev C
  • Woodward 8272-132 B - POWER SENSOR
  • Woodward 9907-028 - SPM-A Synchronizer
  • Woodward SA-3678-AM-2 - Overspeed Electric Governor, Model ESSE2-AM
  • Woodward E8250-502 - GOVERNOR ACTUATOR
  • Woodward 8440-1884 J - Controller EASYGEN-2500-5
  • Woodward 5441-693 - DIGITAL I/O MODULE -MISSING PART
  • Woodward SA-4450 - Speed Controller APECS 3100 For Magnetic Pickup
  • Woodward 9903-466 - 701 DIGITAL SPEED CONTROL REV G
  • Woodward 1765-843 - Governor Speed Adjusting Motor P/N Type: SMM40 220V AC 50/60Hz
  • Woodward 9905-760 - Linknet Termination Module
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward 5484-721 - motor
  • Woodward 8440-1734 - MFR-2 Rev.A Multi Function Relay MFR-2
  • Woodward CSC3SUWA - Controller
  • Woodward 8440-1667 - REV B SPM-D1010B/XN
  • Woodward 8406-120 - egcp-2 digital control
  • Woodward DPG-2201-002 - DIGITAL CONTROLLER REV D
  • Woodward 8272-516 - Pm Engine Control Rev J
  • Woodward 8440-1831 - EASYGEN 3200-5 P/N: REV. K - WITHOUT ACCESSORIES
  • Woodward 8273-101 - LOAD SHARING & SPEED CONTROL
  • Woodward 8440-1855-G - EASYGEN-2200-5 /P1 12/24VDC GENSET CONTROLLER
  • Woodward 9907-247 - 828 DIGITAL CONTROL UNIT REV K
  • Woodward LR21035 - MFR1 MULTI FUNCTION RELAY REV J
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9905-204 - Rev N SPM-A synchronizer
  • Woodward 8521-367 - UG-8 P/N r R.P.M 750-1280 Governor / UG8
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 5464-645 - DRIVER MODULE REV A 2C ACT DRIVE
  • Woodward 8404-009 - PROACT DIGITAL PLUS FRONT PANEL REV J
  • Woodward 9907-175 - Load Sharing Module Rev. B
  • Woodward 8406-102 - Rev A EGCP-2 Digital Control Engine Generator 8406102
  • Woodward EASYGEN-2500-5 - Controller Genset
  • Woodward 8440-2082 - Controller
  • Woodward 8272-516 - PM MOTOR CONTROL REV J
  • Woodward 9905-373 - Digital Synchronizer and Load Control 18-40 VDC Rev P
  • Woodward 5501-429 - Actuator Controller 25mA 2 Channel , (UPP)
  • Woodward 8440-1869 - SPM-D10 Synchronizing System Control-SPM-D10B/PSY4-F-D
  • Woodward 9907-175 - Load Sharing Module Rev. A
  • Woodward 8200-224 - Servo Position Controller
  • Woodward 9906-619 - 723 PLUS DIGITAL CONTROL ( 8280-604 )
  • Woodward 8440-1519 - EASYGEN PART NO: REV: 4
  • Woodward 5501-371 - REV C MODULE- MICRONET SIMPLEX MPU & AIO FTM
  • Woodward EASYGEN-3200-5/P1 - Generator Controller Module Rev F
  • Woodward 8440-1884K - GENERATOR CONTROLLER EASYGEN-2500-5 REV,K
  • Woodward 5466-353 - REV C NETCON MAIN CHASSIS TRANSCEIVER