Sysmex XN-L series (XN-530/XN-430/XN-330) fully automatic blood cell analyzer

From: | Author:Wang | Time :2026-09-23 | 240 visit: | 🔊 Click to read aloud ❚❚ ▶ | Share:

Sysmex XN-L series (XN-530/XN-430/XN-330) fully automatic blood cell analyzer

Introduction

Instrument use: In vitro diagnostic fully automatic blood cell analyzer for clinical laboratories, which can only detect human whole blood or quality control blood; Using electrical impedance, laser scattering, and fluorescence staining techniques, quantitative, identification, and proportion analysis of blood tangible components such as red blood cells, white blood cells, and platelets are completed. The instrument results cannot replace clinical diagnosis and judgment. Failure to operate according to the manual will result in the loss of product warranty.

Model differentiation

XN-530: Configure an independent external display and support batch injection with a sampler;

XN-430: all-in-one machine, built-in touch screen, injector analysis mode;

XN-330: all-in-one machine, built-in touch screen, open manual sampling.

Reportable parameters

Note: MCV/MCH/MCHC are derived parameters for calculation; MicroR and MacroR are not detectable in pre dilution mode.

WDF channel (five categories of white blood cells): absolute values and percentages of WBC, neutrophils, lymphocytes, monocytes, eosinophils, and basophils, immature granulocyte IG #, IG%;

RBC/PLT channel: RBC、PLT、HCT、MCV、MCH、MCHC、RDW‑SD、RDW‑CV、PDW、MPV、P‑LCR、PCT、MicroR、MacroR;

HGB channel: Hemoglobin HGB.

Manual symbols, trademarks: define warning, biohazard, high temperature, static electricity and other document identification; List product identifiers such as IVD, LOT, REF, etc; Sysmex, CELLPACK, etc. are trademarks of our company, while Windows is a trademark of Microsoft.

Compliance certification: CE (EU IVD Directive 98/79/EC, RoHS, Radio Equipment Directive), EAC Eurasian Economic Union certification.

Security Information

2.1 General Electric Safety

Avoid getting hair, fingers, and clothing caught up in the instrument during operation; Prohibit liquids and metal foreign objects from falling into the machine; Do not touch the internal circuit board; The power supply specified on the nameplate must be used and reliably grounded; The power cord must not be pulled under heavy pressure; If there is any odor/smoke, immediately turn off the power and contact after-sales service.

Prohibit analysis of coagulated blood; Prioritize using CELLCLEAN AUTO for maintenance and cleaning, or manually replace CELLCLEAN.

2.2 Installation Safety

Unpacking, installation, and initial debugging must be completed by Sysmex technicians; The user's self movement of the machine is not covered by the warranty; Power off before connecting external devices;

Installation environment: Waterproof splash, avoid high temperature and humidity, dust, direct sunlight, vibration; Good ventilation; Stay away from electromagnetic interference equipment, chemicals, and flammable anesthetic gases; Indoor use only; The height difference between the reagent container and the bottom of the instrument is ≤ 1m. It is prohibited to place reagents on the top of the instrument.

2.3 Electromagnetic Compatibility (EMC)

Compliant with IEC61326-2-6, CISPR11 Class A equipment, wireless interference may occur in home environments; Built in 13.56MHz RFID radio frequency identification module. FCC Class A digital devices.

2.4 Biological Infection Prevention (Key)

Gloves, masks, goggles, and lab coats must be worn for testing and maintenance; Wash hands after operation; The waste liquid pipeline must be connected to the waste liquid collection container; Prohibit bare handed contact with waste liquid components; In case of sample/waste liquid splashing, rinse with plenty of water and follow laboratory procedures to remove contamination; Immediately flush and seek medical attention if liquid enters the eyes/wound.

The scrapping of instruments and accessories belongs to infectious waste and is not subject to the EU WEEE public recycling regulations. Ordinary garbage recycling is prohibited, and it is recommended to incinerate contaminated parts and contact Sysmex for disposal.

Instrument decontamination: disinfect the external surface after daily work, contamination, and before maintenance; Power off and clean again. Only external wiping is allowed, and internal disassembly and cleaning can only be carried out by maintenance engineers.

2.5 Reagent, laser, computer, software safety

CELLPACK diluent is conductive. If it spills into the circuit area, power off and wipe it dry; CELLCLEAN AUTO contains sodium hypochlorite, which can corrode the casing and be immediately wiped off if splashed.

Built in Class I semiconductor laser, enclosed casing, only for authorized engineers to disassemble, to prevent eye damage.

Only authorized maintenance tools from the original factory can be used; The instrument is virus-free from the factory, but external USB storage media needs to be scanned for viruses.

It is prohibited to install or run any non pre installed software, and third-party software causing malfunctions will be exempted from liability by the manufacturer.

Operators must undergo formal training; Please refer to the fault manual first for troubleshooting. If unable to resolve the issue, please contact Sysmex engineers.

Multiple warning labels are printed on the machine body: Do not reach into the machine during operation; Multiple components are marked with biological infection risks; High temperature anti scalding of the air pump casing; The power cord must be unplugged for disassembly and maintenance.


Component Name and Function

1. XN‑530

Analyzer body: injector start stop switch, mode switch, main power switch, left and right adapter brackets, multiple sets of status LED indicator lights, manual injection component;

Independent touch screen display: OSD adjustment buttons, power, VGA video, USB touch signal interface.

2. XN‑430

Integrated machine touch screen; power switch; Analysis status LED; Sample rack open/close button; Sample test tube holder.

3. XN‑330

Integrated machine touch screen; Power Supply; Status LED; Direct suction pipette, start button, no automatic sampler.

4. Machine universal external interface (backplane)

RS-232C serial port, VGA (XN-530), LAN port, multiple USB ports; Fuse holder; AC power input; Various reagent suction interfaces (DCL, SLS, WDF); Waste liquid outlet; RU-20 reagent tank sensor, waste liquid full sensor, pneumatic unit PU-17 control interface.

5. Internal components of the machine

Dye placement position, right maintenance cover lock buckle; Air pump unit, RBC detector, pneumatic buffer chamber, puncture sampling needle (530/430); Semiconductor laser components; Fluorescent dye nozzle; High temperature components of the air pump, etc.

6. Optional pneumatic unit PU-17

Provide positive and negative air pressure to the entire machine, and be careful not to block the exhaust holes on the back.

Installation

The installation and relocation of the entire machine must be carried out by Sysmex engineers, and unauthorized movement will result in loss of warranty.

Environmental conditions: ambient temperature of 15-35 ℃; Relative humidity 20-85%;

Dimensions and Weight

Model Width x Depth x Height (mm) Weight

XN-530 analyzer 450 × 660 × 450 53 kg

XN-530 monitor 267 × 205 × 240 3 kg

XN‑430 450×460×440 35 kg

XN‑330 450×460×510 35 kg

At least 30cm of maintenance space should be reserved on the back of the instrument.

Power supply: 100-240V AC, 50/60Hz; XN-530 consumes 250VA, XN-430/330 consumes 235VA; Class I protection.

Storage conditions (non operational): Temperature -10~60 ℃, humidity -10~95%, no condensation; Atmospheric pressure 70-106kPa; The operating pressure is 70-106kPa.

Noise level ≤ 60dB (excluding test tube clamping and alarm sound).


Instrument Technical Specifications

1. Detection speed (throughput)

Whole blood mode/pre dilution mode: CBC and CBC+DIFF both have a sample rate of approximately 60 samples per hour (XN-530 does not include additional functions such as barcode and retest).

2. Sample suction volume

Whole blood mode: 25 μ L;

Pre dilution mode: 70 μ L.

3. Report scope and display scope

Distinguish between "whole blood mode" and "pre dilution mode", list the reportable upper and lower limits and display upper and lower limits of WBC/RBC/HGB/HCT/PLT, as well as five categories and IG. The reporting range of some indicators in the pre dilution mode has narrowed.

4. Analyze performance indicators

Including blank limit LoB, detection limit LoD, and quantification limit LoQ; Linear; Precision (repeatability, reproducibility); Accuracy; Carry a complete set of technical indicators for carrying pollution rates.

Carrying pollution calculation formula: Caryover= left [ frac {(1st Low -3rd Low)} {(3rd High -3rd Low)} right] × 100.

5. Sample storage stability

Under refrigeration conditions of 18-26 ℃/2-8 ℃, EDTA anticoagulant can stabilize WBC/RBC/HGB for 72 hours; HCT and MCV can be stored at room temperature for 8 hours and refrigerated for 24 hours; PLT can be stored at room temperature for 48 hours; and white blood cell classification indicators can be stored at room temperature for 48 hours. Restore the refrigerated sample to room temperature before loading onto the machine.

6. Interference factors and interfering substances

The sample itself interferes

Pseudo reduction of HCT: red blood cell agglutination (condensation), small red blood cells, and red blood cell debris;

Pseudoelevation of HCT: significantly increased white blood cells (>100000/μ L), severe diabetes, uremia, spherical red blood cells;

Pseudo reduction of PLT: platelet aggregation, pseudo thrombocytopenia, giant platelets;

Pseudo elevation of PLT: small red blood cells, red blood cell debris, fragmented white blood cells, and cold globulin.

External interferents: Bilirubin C, Bilirubin F, Hemolytic Hemoglobin, Lipoemulsion, Chylyl give the highest concentration without significant interference, and the evaluation criteria refer to CLSI H26-A2.

7. Support sample tube specifications

XN-530/XN-430 conventional tube: with a cap, the total length is 70-85 mm, and the outer diameter is φ 11-15 mm; a special adapter is required for a φ 15mm test tube;

XN-330: outer diameter of φ 11-15mm, length ≤ 85mm;

Micro blood collection tubes are classified into three types of shapes: A/B/C, with clear size limitations; RBT raised bottom microtubes are used for batch injection of XN-530/430; List validated blood collection vessel brands (Terumo, BD, Greiner, SARSTEDT).

Batch injection requires Sysmex original injection adapter, and different test tubes need to adjust the adapter metal accessories.

8. XN-530 barcode specifications

Requirements for barcode pasting location; Readable barcode types: ITF, CODABAR, CODE39, ISBT128, CODE128, JAN/EAN/UPC; Quality control blood uses a special CODE128 barcode; Barcode reading errors will automatically assign sample numbers starting with ERR, and special sample numbers such as QC and CAL-CAL will be marked.

9. Detection principle

Fluid focused DC impedance method: RBC, PLT counting, HCT obtained from red blood cell pulse height; Sheath flow wraps cells through small holes one by one, reducing false pulses and improving counting accuracy.

Semiconductor laser flow cytometry (WDF channel): forward scattered light (cell size), lateral scattered light (intracellular/nuclear), lateral fluorescence (dye labeled cell contents), five categories of white blood cells, while detecting immature granulocytes in IG.

SLS hemoglobin method: cyanide free hemoglobin detection, combining the advantages of sulfur hemoglobin method and oxygenated hemoglobin method, with fast conversion speed, can process methemoglobin in quality control samples.

10. Schematic diagram of fluid circuit

Provide complete liquid flow diagrams for whole blood mode and pre dilution mode, indicating the volume and dilution ratio of each reagent added.

11. Parameter calculation formula

The manual provides all calculation formulas for MCV, MCH, MCHC, RDW-SD, RDW-CV, PDW, P-LCR, MPV, and PCT.

12. Software storage specifications

Up to 100000 sample data can be stored; 10000 patient files; Quality control L-J chart, calibration log, reagent replacement log, and maintenance log capacity limit.


Consumables, Accessories, and Options

Consumables Suppliers: fuses, air pump components;

Standard accessories: various reagent pipettes, power cords, three manuals, brushes, screwdrivers, bottle openers, zip ties, test tube holders, injection adapters, anti-static connectors, etc;

Options for purchasing accessories: graphic printer, list printer; Waste liquid full sensor; Handheld barcode reader; PU-17 pneumatic unit.


Reagent

List the complete set of designated reagents for the instrument: CELLPACK DCL、CELLPACK DST、SULFOLYSER、Lysercell WDF、Fluorocell WDF、CELLCLEAN AUTO; Quality control blood XN-L CHECK; Calibration standard XN-CAL. Instructions for each reagent: expected use, ingredients, storage conditions, expiration date after bottle opening, operating precautions, and disposal.

Key point: The reagent is only suitable for use with Sysmex compatible instruments; Non refillable containers; Expired, cloudy, and discolored products are prohibited; Avoid skin and eye contact; Some reagents contain sodium hypochlorite, methanol, etc. Although quality control blood and calibration samples are used for screening infectious diseases, they are still processed as infectious samples.


Service data and research parameters

Important reminder: Service data and research parameters are only used for instrument monitoring and are prohibited from being used for clinical diagnosis of patients. The research parameter software interface is marked with a gray background color.

Service Data: View in the Service tab of the Data Browser, divided into 4 sub pages

RBC/PLT: Sampling raw pulses R‑MFV/P‑MFV、 Position LD-MD-UD of the discriminator, information on clogged bubbles;

WDF: Flow sampling counting, scattered light/fluorescence signal intensity, laser drive current, iRBC counting;

HARDWARE hardware: component operation counter, temperature, pressure, laser cumulative oscillation time, various sensors;

ADJUSTMENT sensitivity adjustment parameters.

Research Parameters

WBC research parameters: total number of nucleated cells in TNC WBC‑C/WBC‑D、NRBC#、NRBC%、HFLC、 Fluorescence intensity and distribution width of scattered light from various types of cells;

RBC/PLT study parameters.

  • GE 369B1860G0026 MPU50 Nexus Controller
  • GE IS420ESWBH3A Industrial ESWB Ethernet Switch
  • GE IS420ESWBH2A Mark VIe IONet Network Switch
  • GE IS200SRTDH2ACB RTD Terminal Board Mark VI
  • GE SR469-P5-HI-A20 Motor Protection Relay
  • GE VMIVME-7750 Pentium III VME CPU Module
  • GE IS215UCVEH2AE VMIVME-7614-132 VME Controller Card
  • GE MVDL800-47931101-A Liquid-Cooled Delta Module for MV3000 Medium Voltage Drive Systems
  • ABB BRC410 SPBRC410 Harmony Bridge Controller
  • ABB PFCL201CE-50kN 3BSE006699D0005 Pressductor PillowBlock Load Cell
  • ABB 5SHY3545L0009 3BHB013085R0001 IGCT Module
  • Wika IPT10 - Process Pressure Transmitter
  • Omron SK20-C1DT-D - Programmable Controller PLC Unit
  • Foxboro Eckardt (Schneider) AE214 - Field Indicator Digital Display Meter
  • Omron CJ1W-OD232 - Transistor Output Unit PLC Module
  • Jetter JX2-IO16 - Digital Input Output Module PLC
  • SEFI ACS 48.6A-NS - Power Supply Unit
  • Schneider (Telemecanique) XBTF011110 - Magelis Membrane Keyboard Overlay
  • Siemens 6ES5246-4UA41 - Simatic S5 Positioning Module
  • Siemens 6SL3120-2TE13-0AA3 - Sinamics S120 Dual Motor Module Inverter
  • SEW Eurodrive MAS51A005-503-50 - Movidyn Servo Drive Controller
  • Record ATE 20 - Automatic Door Brake Motor
  • Record ATE STA 21 - Automatic Door Brake Motor
  • Sanyo Denki R2AA06040FXP02 - AC Servo Motor
  • Omron NX-ID4442 - DC Digital Input Unit PLC Module
  • Schneider (Telemecanique) XBTGT2330 - Magelis Advanced Touch Panel HMI
  • ABB DX561-A1 - AC500 Digital Input Output PLC Module
  • SEW Eurodrive MC07B0004-2A3-4-00 - Movitrac B AC Frequency Inverter Drive
  • Schneider (Telemecanique) FT20CBCL030 - Connection Communication Cable
  • Visions AXFR 600601 - Gap Control Side Board PCBA
  • Allen Bradley 1797-CEC-A-C01 - Flex Ex Communication Interface Adapter
  • Siemens 6ES5095-8MC03 - Simatic S5 Programmable Controller CPU
  • Tectrol / Pitney Bowes TC53S-1392 - Power Supply Unit
  • Bronkhorst P-702C-FAC-88-Z - Digital Mass Flow Controller
  • Allen Bradley 1757-SRM - ControlLogix Redundancy Module
  • Neste 0635-107 - Control Board for SLX Automatic Sliding Door
  • RSF Elektronik MS 2x.x4 MO - Linear Encoder Sensor
  • Pro-face GP37W2-BG41-24V - Graphic Terminal Operator Panel HMI
  • Allen Bradley 2711P-RP1 - PanelView Plus Logic Module HMI
  • ABB (Asea Brown Boveri) GNT0144700R0004 - Power Supply Electronic Board Module
  • SEW Eurodrive MC-LTE-B-0008-2B1-1-40 - Movitrac LTE AC Frequency Inverter Drive
  • Siemens 3RK1301-0AB10-0AA4 - Direct Starter Modular Motor Starter
  • Yaskawa SGDB-15VD - Servopack Servo Drive Amplifier
  • National Instruments NI 9421 - 8-Channel C Series Digital Input Module
  • Yaskawa SGDB-10VD - Servopack Servo Drive Amplifier
  • National Instruments NI 9476 - 32-Channel C Series Source Digital Output Module
  • Pitney Bowes R782000 - Turbojet Controller Board PCBA
  • Lika IT65-Y-1000BND2 - Incremental Encoder Sensor
  • Came 002ZT6 - Control Panel Board for Gear Motors
  • Desin HS-300/7500 - Multivariable Process Controller Unit
  • Pilz PNOZ mc1p - Modular Safety Relay Controller
  • Innovative Robotics PTNR2-2-NES - Controller Interface Board Module
  • Schneider Electric (Telemecanique) TSXCB4020 - Printer Communication Link Cable
  • Wika IPT10 - Process Pressure Transmitter
  • Schneider Electric (Modicon) TSXDMF342A - Extension Digital Analog Module for TSX17 PLC
  • Omron F150-KP - Vision System Cursor Key Pack Console
  • National Instruments BNC-2110 - Shielded Connector Block Accessory
  • Bosch Rexroth (Indramat) CSH01.2C-SE-EN2-EN2-CCD-NN-S-FW - Servo Drive Control Panel Interface Module
  • GHM / Gefran / Baumer GHM510573A/1000 - Incremental Encoder Sensor
  • National Instruments NI 9425 - 32-Channel C Series Digital Input Module
  • Schneider (Telemecanique) STBDDO3705 - Digital Output Module STB
  • Siemens 6EP1436-1SH01 - Regulated Power Supply Unit
  • Schneider Electric (Modicon) TSXFPP20 - Fipway PCMCIA Communication Board
  • April QMB 3202 - PLC Output Card Module with Parameter Surveillance
  • Siemens 6ES5240-1AA12 - Simatic S5 Communication Processor Module
  • Midi Engineering MI907A - Stepper Motor Midi Amplifier Driver
  • Schneider Electric (Telemecanique) TSXAEZ414 - TSX Series Analog Input Module
  • Schneider (Telemecanique) TSX17-20 - TSX17 Compact PLC Controller Unit
  • Siemens 6ES5955-3LC14 - Simatic S5 Modular Power Supply Unit
  • Schneider (Telemecanique) ATV66U72N4 - Altivar 66 AC Frequency Inverter Drive
  • Omron NX-OD4256 - Transistor Output Unit PLC Module
  • Yaskawa / Omron SGDH-04AE-OY - Sigma II Servo Drive 400W
  • RSF Elektronik MS 20.04-2M - Linear Encoder Scale Sensor
  • ITT GMW (Metrosx) DAA288-240 A - LED Message Display Board
  • Allen Bradley 1757-SRM - ControlLogix Redundancy Module
  • Sensorex Alpha-LSE - Display Inclinometer Indicator
  • Omron NX-DA3603 - Analog Output Unit PLC Module
  • Grundig Electronic NRP 02 - Power Supply Control Unit Module
  • ProSoft Technology RLX-FHES-F - RadioLinx Industrial Wireless Hotspot Router
  • Omron NX-EIC202 - EtherCAT Coupler Unit PLC Module
  • Omron NX-TS3201 - Temperature Sensor Input Unit PLC Module
  • Omron CQM1-CPU41-V1 - Sysmac CQM1 PLC CPU System
  • April CPU5001 - PLC CPU Processing Unit
  • Yaskawa JZDP-D008-020-E - Linear Servo Motor Actuator
  • Bronkhorst P-702C-FAC-88-Z - Digital Mass Flow Controller
  • Allen Bradley 2711-K3A17L - PanelView 300 Operator Terminal HMI
  • Schneider (Telemecanique) TSXAEM411 - TSX Series Analog Input Module
  • Schneider Electric (Telemecanique) XBTGT5330 - Magelis Advanced Touch Panel HMI
  • Siemens 6ES5928-3UA12 - Simatic S5 Central Processing Unit PLC
  • Schneider (Telemecanique) TSXSUP65 - Power Supply Module
  • Schneider (Telemecanique) TSXLES61 + TSXLES60 - TSX Series Fine Line Box Local Module
  • Siemens 6SE6440-2AD23-0BA1 - Micromaster 440 AC Frequency Inverter Drive
  • National Instruments NI 9205 - 32-Channel C Series Analog Input Module
  • Yaskawa CIMR-PCC42P2 - Varispeed AC Frequency Inverter Drive
  • ABB PM554-T-A1 - AC500 PLC CPU Module
  • National Instruments cDAQ-9178 - 8-Slot CompactDAQ USB Chassis Backplane
  • Allen Bradley 1786-RPA - ControlNet Repeater Adapter Module
  • Allen Bradley 1770-KFD - DH-485 Communication Interface Module
  • Grundig Electronic NSP 02 - Power Supply Control Unit Module
  • Teq Q07.K3S.002A - Control Panel Logic Board
  • Allen Bradley 1300-ITSSC - Signal Converter Interface Module
  • Omron CQM1H-CPU51 - CQM1H Modular PLC System
  • ProSoft Technology 4207-DFNT-MCM - ProLinx Industrial Gateway Module
  • Schneider Electric TSXSCP114 - RS485 PCMCIA Communication Board
  • Grundig NGE 01 - Power Supply Unit
  • Grundig NZP 03 - Power Supply Unit
  • Siemens 6ES5246-4UA41 - Simatic S5 Positioning Module
  • Danaher / Atlas Copco / Socapel SAM-PA-400-30-E - Servo Power Supply Controller Unit
  • Klöckner Moeller EM4-101-DD1 - Easy Control Relay Module
  • Bosch Rexroth DKC-10.3-012-3-MGP-01VRS - Indramat Digital Servo Controller Drive
  • Schneider (Telemecanique) XBTGT2110 - Magelis Touch Panel HMI with Cutter
  • Berger Lahr (Sig Positec) WD3-004.1802 - Stepper Motor Controller Driver
  • ProSoft Technology MVI56-WA-EIP - ControlLogix Wireless EtherNet/IP Communication Module
  • Allen Bradley 1794-ACNR15 - Flex I/O ControlNet Adapter Module
  • Fanuc A06B-6096-H201 - Servo Amplifier Module
  • Panasonic MSDA083A1 - AC Servo Driver Amplifier
  • Teq Q07.K3P.003B - Control Panel Logic Board
  • Schneider (Telemecanique) XBTH002010 - Magelis Operator Terminal HMI
  • Wika IPT10 - Process Pressure Transmitter
  • Teq Q07.A4P.001A - Control Panel I/O Module Board
  • Teq Q07.A3L.003A - Control Panel Module I/O Board
  • Siemens 6ES5246-4UA31 - Simatic S5 Positioning Module
  • Mitsubishi / Harmonic Drive HC-KFS43 - AC Servo Motor with Harmonic Reducer
  • Mitsubishi HC-KFS43 - AC Servo Motor
  • SES Store Electronic Systems 37120/120 - VLF Radio Transmitter Label System
  • Siemens 6SE9213-6BA40 - Micromaster AC Frequency Inverter Drive
  • Rosemount 1151DP5S22 - Differential Pressure Transmitter
  • Siemens 6FM1470-4AA20 - Simatic FM 470 Positioning Module Processor