K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
新闻动态
newS
   
Brand

EATON XV-303/XV-313 series multi touch display

From: | Author:Wang | Time :2026-03-11 | 221 visit: | 🔊 Click to read aloud ❚❚ ▶ | Share:


EATON XV-303/XV-313 series multi touch display

Basic Information and Core Product Specifications

Product positioning and applicable scenarios

Equipment type: Can be used as an independent HMI monitoring device or an integrated HMI/PLC control device;

Applicable fields: Designed specifically for mechanical and system manufacturing, used for equipment visualization, operation, and control. Other uses require confirmation from the manufacturer;

Core difference: XV-303 is front mounted (embedded in the front of the control panel), while XV-313 is rear mounted (flush with the panel surface).

Core hardware and model division

Display system:

Size Resolution Visible Area Contrast Brightness

7.0" 1024×600 153.6×90.0mm 850:1 400 cd/m²

10.1" 1024×600 222.72×125.28mm 500:1 400 cd/m²

15.6" 1366×768 344.23×193.54mm 500:1 400 cd/m²

Common features: Capacitive Multi touch (PCT), Anti glare Tempered Glass, LED Backlight (with a lifespan of 50000 hours and software adjustable dimming);

Hardware configuration: 800 MHz ARM Cortex-A9 processor, 512 MB RAM, 1GB SLC flash memory, 128kB non-volatile storage, supports SD/SDHC card expansion (SDA 2.0 specification); Built in 3V lithium battery (BR-2330/GNU), with a backup lifespan of 10 years for power-off clock (at 25 ℃);

Model classification: According to the combination of "installation method+size+interface+version+software", the core model examples are as follows:

Installation method, size, interface configuration, software package, model example

Front end (XV-303) 7.0 "1 Ethernet visualization software XV-303-70-B00-A00-2B

Front end (XV-303) 10.1 "2 Ethernet visualizations+PLC software XV-303-10-C00-A00-2C

Rear (XV-313) 7.0 "1 Ethernet visualization+PLC software XV-313-70-B00-A00-2C

Rear (XV-313) 10.1 "2 Ethernet visualizations+PLC software XV-313-10-C00-A11-2C

Key technical parameters

Power supply: 24 VDC SELV/PELV, allowable voltage range 18.0-31.2 VDC (including ripple), short-term (<100ms) can withstand 35 VDC; Maximum power consumption of 21.6 W (15.6 "model), continuous current of 0.6-0.9 A;

Protection level: front panel IP65 (splash proof and dustproof), back panel IP20;

Physical dimensions and weight:

Model Series Size Weight Installation Cut (Example)

XV-303 (front) 7.0 "0.74 kg 196 × 135mm

XV-303 (front) 10.1 "1.13 kg 269 × 174mm

XV-303 (front) 15.6 "3.25 kg 401.7 × 254.9mm

XV-313 (rear) 7.0 "0.8 kg 182.7 × 126.8mm

XV-313 (rear) 10.1 "1.21 kg 255.7 × 165.8mm

Environmental adaptability: operating temperature 0-50 ℃, storage/transportation temperature -20-60 ℃, humidity 10-95%, no condensation; The highest altitude is 2000 meters.


Safety regulations and core taboos

Personnel and operational requirements

Qualification requirements: Installation, operation, and maintenance personnel must be professional electricians who comply with EN 50110-1/-2 (VDE 0105 part 100) standards;

Manual usage: The complete and latest manual must be used, and single page operations are prohibited (to avoid missing safety information);

Prohibited from use: Safety functions that cannot be used for personnel or equipment protection, can only be used for routine control and visualization.

Core security risks and preventive measures

table

Potential risk prevention measures

Explosion risk (explosive environment/lithium battery) is only used in non explosive environments or ATEX Zone 22; Improper disposal of lithium batteries is prohibited, and the equipment needs to be professionally recycled

Electric shock risk (opening cover): Do not open the cover by yourself, as it contains live parts inside

Static electricity damage (electronic components): Before touching the device, ground it to release static electricity; Avoid contact with sensitive components such as interface pins

Data loss (SD card/memory): Only power off and unplug the SD card; Reduce write operations (limited write cycles on storage media); Confirm no write operation before closing

Condensation short circuit (temperature fluctuation): Do not apply electricity during condensation; After the temperature changes, it needs to be allowed to stand at room temperature before starting

Touch screen damage (sharp objects) can only be operated with fingers or a dedicated stylus; Avoid corrosive cleaning agents

Stray current fire requires parallel laying of equipotential bonding conductors (with a cross-section of multiple shielding layers of the cable)

Environmental and installation restrictions

Avoid direct sunlight exposure (UV can cause plastic to become brittle);

Signal cables and power cables cannot be laid in the same slot and need to be wired separately;

The equipment needs to be installed inside a fire-resistant enclosure (UL certification requirements).


Installation process and specifications

Installation prerequisites

Installation location: inside the control cabinet/control panel, can be installed horizontally/vertically; The SD card slot cannot face downwards (to prevent the card from falling off);

Spacing requirements: ventilation gap ≥ 30mm, distance from heat sources (such as transformers) ≥ 15cm;

Installation surface requirements: XV-303 requires a 2-5mm thick panel, XV-313 requires a 1.5mm (A00 version) or 2mm (A11 version) thick panel, with a flatness of ≤ 0.5mm.

Cable and wiring specifications

Common requirements for cables: All interfaces require shielded cables, and the shielding layer should be connected to the connector housing with low impedance to ensure EMC compliance;

Interface - Specific Requirements:

Interface cable specifications, maximum length, terminal resistance

CAN characteristic impedance 120 Ω, capacitance<60pF/m 5000m (10 Kbit/s) 120 Ω (at both ends of the bus)

RS-485 characteristic impedance 120 Ω, loop resistance<110 Ω/km 1200m (9600 Kbit/s) 120 Ω (at both ends of the bus)

Ethernet shielded twisted pair (STP), CAT5e/6 100m none

RS-232 shielded cable 30m (9600 Kbit/s) None

Grounding specification: The cross-sectional area of the functional grounding wire should be ≥ 1.5mm ² and the length should be ≤ 350mm. It should be connected to the equipment grounding screw (tightening torque 1.3 Nm).

Equipment fixation and sealing

XV-303 (pre installation): Use 6/10/12 brackets (according to size) to fix from the back of the panel, with a tightening torque of ≤ 0.1 Nm for the brackets. Before installation, place a sealing strip in the equipment groove (with the joint facing downwards and no distortion) to ensure IP65 protection;

XV-313 (rear installation): Weld M4 × 12 bolts on the panel, fix the equipment with washers and nuts to ensure no gaps;

Power wiring: Use the matching MSTB 2.5-3-ST-5.08 plug, with a wire cross-section of 0.75-2.5mm ², a stripping length of 7mm, and a tightening torque of 0.6-0.8 Nm.

Operation and maintenance

Startup and shutdown

Startup process: Power off, insert SD card containing software → Connect 24 VDC power supply → Power on, automatic boot → Install GALILEO/PLC (XSoft CoDeSys 3) software → Complete system configuration;

Closing process: Confirm that there are no SD card write operations → Disconnect the power supply; No independent switch, avoid frequent switching (prolong backlight life).

routine maintenance

Touch screen maintenance: Clean with a clean, soft and damp cloth. For stubborn stains, spray a small amount of cleaning agent on the cloth (do not directly spray the device); When responding to anomalies, it is necessary to calibrate according to the Linux system manual;

Battery maintenance: The built-in lithium battery is maintenance free, with a lifespan of about 10 years, and cannot be replaced;

Maintenance restrictions: Equipment malfunctions can only be reported to the manufacturer or authorized center, and self opening repairs are prohibited.

Common troubleshooting

Possible causes and solutions for the fault phenomenon

The device cannot start without 24 VDC power supply/SD card not inserted Check power cable → Insert SD card with software → Confirm power supply voltage is between 18.0-31.2 VDC

Touch screen unresponsive, poor grounding/uncalibrated/disabled. Check function grounding (cross-section ≥ 1.5mm ², length ≤ 350mm) → recalibrate → enable touch screen function

Display black screen backlight disabled/backlight failure. Turn on backlight in visualization software → Contact for repair

Abnormal data transmission, unshielded cable/missing terminal resistor. Replace shielded cable → Add 120 Ω terminal resistors at both ends of CAN/RS-485 bus


Storage, transportation, and disposal

Storage and transportation

Storage conditions: Temperature -20-60 ℃, humidity 10-95%, no condensation, avoid direct UV radiation and severe vibration;

Transportation requirements: Use original factory packaging, inspect the equipment for any transportation damage upon arrival, and retain the packaging for future transportation.

Disposal standards

The equipment contains lithium batteries (BR-2330/GNU) and electronic components, which need to be disposed of professionally according to local environmental regulations, or returned to the manufacturer/sales department;

Packaging materials (cardboard, PE film) can be classified and recycled.


Compliance and Certification

The equipment complies with multiple international standards, and the core certifications are as follows:

Safety standards: UL 61010-2-201, IEC/EN 60950;

EMC standards: 2004/108/EEC, IEC/EN 61000 series;

Explosion proof standard: ATEX 94/9/EC (Zone 22, Category 3D);

Classification Society Certification: The 7.0 "/10.1" model has been certified by DNV GL (DNVGL-CG-0339) and is suitable for ship environments.

  • Siemens 6SL3244-0SA01-1AA0 - SINAMICS G120 Control Unit
  • DANFOSS 175Z2688 - COATEDE CONTROLUNIT VLT5000
  • SIEMENS 6FM1721-3AA20 - Positioning Module
  • REXORTH VTS0605 PVAR S21 - Drive Module
  • BECKHOFF 2915-0000 - Control Module
  • COOPER EATON CGLine 400 40071347901 - CEAG CG Controller
  • SIEMENS 3UF5031-3AN00-1 - SIMOCODE DP Basic Unit
  • SIGMATEK DNC305 05-011-305 - Drive Controller
  • Multivac MV1 10249768 - Control Module
  • SCHNEIDER ELECTRIC MES114 59646 & 59645 - Circuit Breaker Accessory
  • CAMILLE BAUER CAPAX 44-580-0012 - Transmitter
  • HENGSTLER VT360P LS1/TOK - Encoder
  • BURKERT 8792 - 24V DC IP65 / IP67 Positioner
  • SENSOPART V10-OB-A1-W6 - Vision Sensor
  • ALLEN-BRADLEY 1762-L40BXB SER.C REV.J - MicroLogix 1200 Controller
  • HITACHI CPU22-02HC 33025801-2 - CPU Module
  • HITACHI AGH-0 33034810-2 - Control Board
  • PHILIPS AIH110 VER 1.0 - Control Module
  • BAUMULLER DO8000 - Drive Controller
  • B&R PS477 3PS477.9 Rev.C0 - Power Supply
  • ABB ALFA LAVAL 200-CISB - Communication Interface 2 x SatBus
  • Moeller MI4-570-TA1 - HMI Operator Panel
  • ABB ACH550-01-06A9-4+B055 - Variable Frequency Drive
  • ABB TPU2 3HNE00313-1 REV 12 - Teach Pendant Unit
  • Schneider Electric BRS368H130ABA - Stepper Motor
  • Foxboro FCM100E P0972ZA - I/A Series Communication Module
  • Siemens 6ES7 450-1AP00-0AE0 6ES7450-1AP00-0AE0 - Simatic S7 Version:04 Counter Module
  • Schneider Electric ATV320U07N4W - Altivar Machine Drive
  • Priva TouchPoint Flush V06:02 5060002 - Control Panel
  • Lenze ESMD402L4TXA - 4kW SMD Inverter Drive
  • Lenze ESMD402L4TXA - 4kW SMD Inverter Drive
  • Schneider Electric PM210 PM210MG - Powerlogic Power Meter
  • ASCOM U982-DB/1C U982 - Power Supply / Communication Module
  • DYADIC SYSTEMS SCN5-010-050-S03-NA - Servo Cylinder
  • Reliance Electric GMI-S04 - AC/AC CONVERTER 380/400V 50/60Hz 3.9/5.2A
  • Pro-Face GLC150-BG41-XY32KF-24V 3080060 PFXGLC150BDBP - Touch Screen HMI
  • ROFIN RSL TERMINAL V2 0185.01/03 - TERMINAL
  • HONEYWELL R7241E1077 - Burner Control / Amplifier
  • SEW MM22C-503-00 8241201 - 2.2kW Movimot Drive
  • Brand Digital III 50mL - Burette
  • Danfoss 195N0039 VLT2811PS2B20STR1DBF00A00C0 - 2.4kVA VLT Drive
  • SONY LG10-2 EK1 - Digital Gauge Indicator
  • EMERSON SKD3400750 - 7.5kW AC Drive
  • SIEMENS 6AV6 542-0AG10-0AX0 - MULTIPANEL HMI
  • TELEMECANIQUE ATV21HU55N4 - ALTIVAR21 5.5KW Variable Speed Drive
  • MITSUBISHI A985GOT-TBA-EU - GOT900 Touch Screen HMI
  • SCHNEIDER LXM32AD30N4 - Lexium 32 Servo Drive
  • SICK PSR01-1501 M20Z-02550A122 - Safety Laser Scanner
  • GECMA CHALLENGER 15-2-FMO - LITE TOUCH Monitor
  • Uniop EK02 6ZA982 - HMI Operator Panel
  • TELEMECANIQUE ATV18U54M2 - SQUARE D ALTIVAR 18 3kW Drive
  • Schneider Electric ATV312HU75S6 - 7.5kW Altivar 312 Drive
  • Siemens 6GK7243-5DX30-0XE0 6GK7 243-5DX30-0XE0 - Communications Processor
  • Schneider Electric LV432455 VIGI630 - 3POLE Earth Leakage Module
  • Rexroth PSI 6100.750 L1 R911170694-107 - frequency inverter / inverter
  • SWEDISH MICROWAVE AB Ku-Band BDC 138010-45-D0 - Block Downconverter
  • METTLER TOLEDO IND429 IND429-BB30 - Weighing Terminal
  • Siemens 6SL3210-5HE10-4UF0 - Sinamics V90 Servo Drive
  • B&R X20CP0482 Rev.D0 - X20 CPU Module
  • Mitsubishi FR-E720S-110SC-EC FRE720S110SCEC - 31A~11A Drive With Filter
  • ABB ACH580-01-026A-4 - Variable Frequency Drive
  • Siemens 6SL3210-1KE13-2AP1 - SINAMIC G120CDP 1.1kw Drive
  • Schneider Electric TM250D 4P3D LV431440 - Compact NSX250 Circuit Breaker
  • RELIANCE ELECTRIC GD.722.81.00-A 802288-74C - MAXITRON Servo Control Card
  • Uniop EK02 6ZA982 - HMI Operator Panel
  • Siemens 6SE9113-7JA13 - MICRO MASTER Junior 1.5kW Inverter
  • Mitsubishi FR-E720S-110SC-EC FRE720S110SCEC - 31A~11A Drive with Filter
  • Johnson Controls FEC2621 MS-FEC2621-0 - Field Equipment Controller
  • BENDER IR475LYT-429 - A-ISOMETER Insulation Monitor
  • Berger lahr D550 RS15 22.550-00-30b - Stepper Drive
  • Rexroth PSI 6100.750 L1 R911170694-107 - Frequency Inverter / INVERTER
  • KOYO 205 D2-06B-1 D2-240 H2-ECOM D2-08ND3 F2-08TRS - DIRECT LOGIC PLC WITH MODULE
  • TELEMECANIQUE ATV18U54M2 ATV18U54M - SQUARE D ALTIVAR 18 3kW Drive
  • Lenze 471-E1.D - Board / Controller Speed
  • Mitsubishi FR-A740-00038-EC - Frequency Inverter
  • Johnson Controls IOM3723 MS-IOM3723-0 - Input/Output Module
  • CURTIS 1238-5602 - AC Motor Controller
  • FOXBORO P0912XX REV.A - 220VAC Power Supply
  • Siemens 6SE9113-7JA13 - MICRO MASTER Junior 1.5kW Inverter
  • Mitsubishi FR-A740-00038-EC - Frequency Inverter
  • KOYO 205 D2-06B-1 D2-240 H2-ECOM D2-08ND3 F2-08TRS - DIRECT LOGIC PLC WITH MODULE
  • AUTZ M406D-00101 - Servo Motor
  • Lauer PCS095 PG095.508.BB - Operator Panel
  • ABB SCOP45SB/DX232 - SattCon OP45 SB Operator Panel
  • SEW Eurodrive MCH42A0030-5A3-4-00 MDX60A0030-5A3-4-00 - 4.8kVA Movidrive Inverter
  • BENDER IR475LYT-429 - A-ISOMETER Insulation Monitor
  • Johnson Controls FEC2621 MS-FEC2621-0 - Field Equipment Controller
  • Johnson Controls IOM3723 MS-IOM3723-0 - Input/Output Module
  • Berger lahr D550 RS15 22550-00-30b - Stepper Drive
  • SIEMENS 6FX1120-4BD03 6FX11204BD03 5702049304.00 E-Stand: A - Sinumerik Module
  • Allen-Bradley 1771-NIV B - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • HONEYWELL XFC2D06001 - Flow Computer / Controller
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380v - 400v 90A 50kVA
  • Red Lion Control GEM52000 - Control Module
  • Siemens 6ES5 955-3NC13 - modular power supply TYPE:DIN41752
  • Danfoss ICV50 G20Mn50T / 027H5200 - Valve zaw
  • Eberle PLS508 P-814 / 2X EA-88 / A-812 / MT-81 / S-11 - PLC with Modules
  • Siemens 6ES7 314-6CF01-0AB0 6ES7314-6CF01-0AB0 - SIMATIC CPU314C-2 DP
  • EBERLE EM-525-87 EM52487 - ICE DETECTOR BASE UNIT
  • Telemecanique / Schneider TSXRKZ02 - TSX Micro automation plus 7module
  • B&R 5DLSDL.1001-00 - Display Link Receiver
  • Siemens 6FX1120-4BD03 6FX11204BD03 5702049304.00 E-Stand: A - Sinumerik Module
  • ALLEN-BRADLEY 1771-NIV A - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • ALLEN-BRADLEY 1771-NIV B - HIGH RESOLUTION ISOLATED ANALOG SERIES Module
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380V - 400V 90A 50kVA
  • Contraves Varidyn Compact ADB 380.90M - DC Drive 380V - 400V 90A 50kVA
  • Ropex RES-202 - Resistron Temperature Controller
  • HONEYWELL XFC2D06001 - Flow Computer / Controller
  • Telemechanics ATV452U40 - DIMMER ALTIVAR5 SERIES 452 4kW 5HP Frequency Inverter
  • VEGA VEGAPLUS61 PS61.XXAGPHAMAX - Radar Level Sensor
  • BRANSON ULTRASONIC TRANSDUCER - Ultrasonic Transducer
  • Danfoss ICV50 G20Mn50T / 027H5200 - Valve Valvola Zaw
  • Schneider Electric 2001549/1 GALAXY PW 5102851200 NT07 - panler card
  • REXROTH VT3006-36 A - Proportional Valve Amplifier
  • Allen-Bradley 1746-OBP16 SERIES:C - SLC 500 OUTPUT MODULE
  • SCHNEIDER LXM32MD12N4 - Lexium 32 Servo Drive
  • Schneider Electric ATV630U22N4 - 2.2KW Altivar Process Drive
  • Allen-Bradley 1746-OBP16 SERIES:C - SLC 500 OUTPUT MODULE
  • Vanderlande 0E2550-00002... - Bagtrax Integrated Power Module 400V 32A
  • B&R X20CP0410 Rev.D0 - X20 CPU Module
  • VANDERLANDE 0E2550-00002 02EDD2B0100 - BAGTRAX Integrated Power Module 400V 32A
  • Rexroth R061205010 - Linear Bushing / Bearing
  • INDRAMAT TVM1.2-50-220/300-W0-220/380 - Power Supply Module
  • Vanderlande 0E2550-00002... - Bagtrax Integrated Power Module 400V 32A
  • HOMAG KEB 07F5S1A-YA00 09E5T60-1001 - Combivert Inverter WITH KEYPAID AND FILTER
  • Siemens 3RW3047-1BB14 - Soft Starter
  • Sumitomo AF-500 AF502-A40 - 0.4kW Transistor Inverter
  • Sumitomo AF-500 AF502-A40 - 0.4kW Transistor Inverter