K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB CI840 I/O module.
❤ Add to collection

ABB CI840 I/O module.

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

Diagnosis control shows the status of the CI840 and node specific errors and  warnings. Module specific diagnosis are displayed in the Diagnosis control for each  I/O module.

5887.00
¥5000.00
Weight:2.200KG
Quantity:
(Inventory: 30)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

Diagnosis control shows the status of the CI840 and node specific errors and  warnings. Module specific diagnosis are displayed in the Diagnosis control for each  I/O module.


ABB CI840 I/O module.

Figure 23. CI840 - Diagnosis - General Tab

Device state area

This text field shows the actual state of the FCI. Either the state is Operational or

the text field is left blank.

Device diagnostics area

The device specific errors that are detected for the CI840 are:

• Station warning

At least one error is detected within the entire CI840 station (including

I/O modules etc.).

• Redundancy warning

Decreased availability due to error on redundant part in the entire CI840

station.

In system with only single CI840 this warning could be raised if the system is

not correctly configured for single mode.

• Redundant power A failure

For the CI840 or an optical modem.

• Redundant power B failure

For the CI840 or an optical modem.

• CI840 in position A is primary

CI840 in position A is primary in a redundant pair also set if used as single.

• CI840 in position B is primary

CI840 in position B is primary in a redundant pair.

• CI840 error on unit in position A

CI840 in position A is erroneous.

• CI840 error on unit in position B

CI840 in position B is erroneous.

• Redundant cable A failed

The Profibus cable to CI840 in position A is unconnected or broken.

• Redundant cable B failed

The Profibus cable to CI840 in position B is unconnected or broken.

Station address warning

There is a mismatch between the actual address on the CI840 and the one

configured in the system or if the address is set above 62. The warning will be

cleared when the system is restarted with the right configuration or if the switch on

the CI840 is changed back to the configured address.

Configuration

For configuration of the module, select the “Configuration” menu item. It shows the

user parameters for the FCI e.g. Output Hold Time.

This control is not available if the unit is used towards AC 800M. The

configuration data is then set via Control Builder Professional

Figure 24. CI840 - Configuration for AC870P

Sequence of Events

The Sequence of Events checkbox determines the status of the SOE feature in the

supported I/O modules:

• If this checkbox is checked, the SOE drop-down menu in the Channel

Parameters tab of the supported I/O modules is activated. The user can then

select the SOE status for each channel.

• If this checkbox is unchecked, the SOE is disabled for the supported modules,

and the SOE drop-down menu in the Channel Parameters tab of the supported

modules is not activated.

SOE is supported in DI825. DI830. DI831. and DI885 modules.

Power supervision of FCI

Mark the check box if the voltage supply to the FCI shall be supervised. Only if

redundant power supply.

• Power supervision of opto extension

Mark the check box if the voltage supply to the cluster shall be supervised.

Only if redundant power supply.

• Redundancy

Mark the check box if the CI840 shall be configured as a redundant module.

• Extended HART mode

Normal mode shall always be used if HART data is < 56 bytes. Mark the check

box if the HART data is > 56 bytes but < 215 bytes. If Extended HART mode

is chosen less I/O modules can be used. See Memory Maps for more details.

• Output hold time

After a fail over, a timer is started in the new primary CI840. This CI840

requires configuration and data from the Profibus Master within the output

hold time, which is defined in the Output hold time text field. If no data is

received within the defined time, the channels on the output modules are set to

the predefined value (OSP value).

• HCIR Enable

Hot Configuration In Run active

• HCIR Factor

Hot Configuration In Run Factor

• HCIR Watchdog

Hot configuration In Run Worst Case Bus Cycle Base

Configuration Control of DI825/DI830/DI831/DI885 with CI840 for SOE

To use the modules DI825/DI830/DI831/DI885 for SOE, open the

ServiceEntries.xml file, and set the value of the ‘EnableSOE’ attribute to 1.

The location of ServiceEntries.xml is

ABB800xAS800DTM. The ProgramData folder is hidden, by

default.

Table 3 describes the different configuration control options for the SOE supported

modules DI825. DI830/DI831 and DI885. used with CI840 for AC870P.

It is assumed that the EnableSOE attribute is set to 1 globally.

Table 3. Configuration control of SOE supported modules used with CI840. for

AC870P

Status of ‘Sequence of

Events’ checkbox in

CI840 Configuration

Control

Displayed status in the

‘SOE’ drop-down menu in

DI825/DI830/DI835/DI885

Configuration Control

Whether the displayed

SOE status in DI8xx

can be changed

Unchecked, by default,

after inserting the CI840

for the first time

SOE disable No

Checked after an

unchecked status

SOE disable Yes

  • Lenze 8400 StateLine C Inverter Operating Instructions
  • Leybold PENNINGVAC PR25/PR26/PR27/PR28 series passive cold cathode Penning vacuum gauge tube
  • Leybold SOGEVAC DI&BI series oil lubricated rotary vane vacuum pump
  • Leybold THERMOVAC TTR 91/96/911/916 N series vacuum transmitter
  • Leybold TTR 101 series vacuum transmitter
  • Honeywell TC847A1004 Reflective Linear Beam Smoke Detector
  • Oerlikon Leybold Vacuum TURBOVAC series turbo molecular pump operation guide
  • Leuze electronic DDLS 200 series bus type infrared optical data transmission equipment
  • Lam Research 853-012123-004 model harmonic drive component
  • LZS-A1000-3 Power Installation, Operation, and Maintenance Instructions
  • MTL2000 series intrinsically safe isolation safety barrier
  • MTS Temposonics ® GB series (GBS/GBN) analog magnetostrictive linear displacement sensor
  • MTS Temposonics ® R-Series magnetostrictive absolute non-contact displacement sensor
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik family of industrial automation connection and control solutions
  • Nabtesco RV series high-precision reducer
  • NACHI-FUJIKOSHI 2020 Industrial Robot Full Series Products
  • ESD series electro-hydraulic proportional flow directional control valve
  • NEC FC-9801X Industrial Factory Computer
  • GE Vernova Mark VIeS Functional Safety System
  • Typical application cases of NI CompactRIO and sbRIO products
  • NI Single-Board RIO Embedded Control and Acquisition Devices
  • NI SHC68-68-EPM high-performance shielded cable
  • NI SCXI-1349 Shielded Cable Adapter Installation Guide
  • How to install NI SCXI chassis?
  • SNAP PAC System Specification Guide
  • PacSci 6410 Stepper Motor Subdivision Driver
  • TIDA-010210 11kW bidirectional three-phase GaN-ANPC
  • Pepperl+Fuchs K-System isolated safety barrier system
  • Pacific Scientific Powermax II P21NRXS-LNS-NS-03 NEMA 23 specification hybrid stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific's full range of brushless servo drives
  • Pacific Scientific SCE900 series single axis brushless servo drive
  • Schneider Electric Pro face STM6000 series 7-inch widescreen modular HMI
  • Pacific Scientific 6410 2-phase Bipolar Stepper Motor Driver
  • Parker EVM32-II Modular Expansion Base Plate
  • Parker COMPAX-M/S Compact Servo Controler
  • Parker Compumotor ZETA6000 series single axis independent drive controller
  • PI C-663.12 Mercury Step Motor Controller
  • NetTest TUNICS series tunable external cavity laser
  • Guide to Deep Application of Inline Series Automation Terminals
  • Phoenix FL MC 1000 SC (ST) Fiber Optic Converter
  • Phoenix ST series spring cage terminal block
  • ROSS Pneumatic Control System Full Series
  • BD SENSORS DMP 333 Industrial Pressure Transmitter
  • OE Max Controls NX70 series programmable controller
  • SAIA PCD4.W500 (Analog Input Module) and PCD4.W600 (Analog Output Module)
  • Saia Burgess PCD4. U100 kit PCD4 controller upgrade tool
  • SAIA PCD1 series programmable controller
  • SAIA Burgess PCD2.H110 Universal Counting and Measurement Module
  • SAMSON 430 Series 3434 Pneumatic Controller Module
  • SanDisk iNAND ® Series of Embedded Flash Drives (EFDs) and OEM microSD ™ card
  • Optimus® Product Family of SAS SSDs
  • SANMOTION PB series AC power input stepper system
  • ADCA LINEAR ELECTRIC ACTUATORS AVF234S and AVM234S
  • SBS Technologies VIPC616 Four Slot 6U VMEbus IndustryPack Carrier
  • SBS Technologies VIPC616 Four Slot 6U VMEbus IndustryPack Carrier
  • Greenspring P2-Video General Purpose CRT and LCD Video Graphics Controller
  • ABB UniPack-S Steel Compact Secondary Substation
  • Schaffner Ecosine ® Economy Line FS 42842 Compact Passive Harmonic Filter
  • Schenck Process INTECONT® Tersus for Measuring Systems
  • Entrelec compact contactors, small contactors, control relays, and supporting system components
  • Smiths connectors MHD/MDD/MDP series high-density PCB connectors
  • SEW EURODRIVE DFP21B PROFIBUS DP-V1 Fieldbus Interface Description
  • SEW-EURODRIVE MOVIDRIVE ® MDX60B/61B series frequency converter system
  • SEW Eurodrive R series parallel axis gear motor
  • SEW EURODRIVE DFS/DFY series synchronous motors
  • SEW EURODRIVE MOVITRAC 31C series frequency converter
  • SEW EURODRIVE MOVIDYN ® Description of Communication Interface for Servo Controller
  • SEW EURODRIVE's MOVIDRIVE ® Series frequency converter UL certification related technical data sheet
  • SEW MOVIDRIVE ® MD-60A frequency converter bus positioning function
  • SEW MOVIDYN ® Series servo controller
  • SEW EURODRIVE MOVIDRIVE ® MD-60A series frequency converter
  • BTicino Megatiker M5 electronic circuit breakers
  • BTicino Megatiker M4 Thermal magnetic and MS4 trip-free switches
  • BTicino Megatiker M3 160 Thermal Magnetic Circuit Breaker and MS3 160 Isolation Switch
  • Bticino MEGATIKER series industrial distribution protection equipment
  • Elmex brand's industrial control and instrumentation products
  • Danfoss VLT ® Series 3000 series adjustable frequency drive
  • Rockwell Automation SLC 500 Series Programmable Logic Controller
  • YOKOGAWA CENTUM CS 3000 Integrated Production Control System
  • OMRON SYSMAC CS Series CS1G/H-CPU  H Programmable Controller
  • MEGGITT TQ 422/TQ 432/EA 402/IQS 450 Proximity Measurement System
  • MEGGITT VM600 machinery protection system (MPS)
  • IbaDeskline SAS Industrial Computer
  • IbaDAQ-C Compact Device for Independent Data Acquisition
  • IbaFOB io ExpressCard fiber optic interface card
  • IbaPADU-S-IT-16 modular central unit
  • YASKAWA ∑ - II Series SGMBH/SGDH AC Servo System
  • ibaBM-CAN CAN / CANopen Bus Sniffer
  • IbaLink-SM-128V-i-2O VMEbus interface board
  • GE Fanuc 90-30 PLC Hardware Guide
  • Automation Direct GS2 Drives Tech Guide
  • Comprehensive Technical Guide for OMRON 3G3MV Inverter
  • Danfoss VACON NXI Inverter FI9-FI14 Operation Guide
  • Saia PCD4.U100 System Migration Complete Guide
  • Yaskawa NS300 DeviceNet Module Guide
  • OMRON SYSMAC C-series PLC Programming Guide
  • Kollmorgen ServoStar S Drive Installation and Debugging Guide
  • Omron C200HX/HG/HE PLC Installation and Configuration Guide
  • SIEMENS SINAMICS S120 Driver
  • Emerson ControlWave® Micro Hybrid Controller
  • ABB 800xA for Advant Master Configuration
  • OMRON FQM1 Motion Controller Instruction System
  • Schneider Easergy P5 Communication Architecture and Protocol
  • ABB JOKAB SAFETY Pluto series safety PLC
  • Lenze L-force series HMI EL 100 series human-machine interface
  • Pilz PSEN opII4H series safety light curtain operation instructions
  • Danfoss VACON ® NXP and VACON ® NXC series AC frequency converter
  • EATON Crane Control System Complete Guide
  • ProSoft MVI56-PDPMV1 Module: PROFIBUS DPV1 Master Integration Complete Guide
  • DEIF XDi series FLEXIBLE DISPLAY INDICATORS
  • DEIF AGC 100 series generator set controller
  • DEIF AGC-3 Automatic Generator Set Controller
  • DEIF Multi line 2/version 2-GS Multi functional Generator Protection and Control Unit
  • KONGSBERG AIS BS600 shipborne automatic identification system base station
  • KONGSBERG HMS 300 Helicopter Deck Monitoring System
  • Honeywell HPM Series Particulate Matter Sensors
  • HONEYWELL Expert C300 Controller
  • HONEYWELL HCiX series touch panel operation interface
  • Honeywell T901Px1A Inert Gas Pressure & Temperature Transmitter for Liquid Cargo
  • HONEYWELL Expert Series-C I/O Module
  • HONEYWELL INTELLIKNIGHT®MODEL 5700 Addressable Fire Alarm Control Panel
  • HONEYWELL Expert PKS C300 Controller
  • HONEYWELL Experion Local Control Network   
  • HONEYWELL IRIS P522 Signal Processor Flame Monitoring Equipment
  • HONEYWELL EC7830A, RM7830A, EC7850A, RM7850A 7800 SERIES Relay Modules
  • HONEYWELL Sensepoint XCD Flammable, toxic and oxygen gas detector for industrial applications