K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB CI840 I/O module.
❤ Add to collection

ABB CI840 I/O module.

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

Diagnosis control shows the status of the CI840 and node specific errors and  warnings. Module specific diagnosis are displayed in the Diagnosis control for each  I/O module.

5887.00
¥5000.00
Weight:2.200KG
Quantity:
(Inventory: 30)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

Diagnosis control shows the status of the CI840 and node specific errors and  warnings. Module specific diagnosis are displayed in the Diagnosis control for each  I/O module.


ABB CI840 I/O module.

Figure 23. CI840 - Diagnosis - General Tab

Device state area

This text field shows the actual state of the FCI. Either the state is Operational or

the text field is left blank.

Device diagnostics area

The device specific errors that are detected for the CI840 are:

• Station warning

At least one error is detected within the entire CI840 station (including

I/O modules etc.).

• Redundancy warning

Decreased availability due to error on redundant part in the entire CI840

station.

In system with only single CI840 this warning could be raised if the system is

not correctly configured for single mode.

• Redundant power A failure

For the CI840 or an optical modem.

• Redundant power B failure

For the CI840 or an optical modem.

• CI840 in position A is primary

CI840 in position A is primary in a redundant pair also set if used as single.

• CI840 in position B is primary

CI840 in position B is primary in a redundant pair.

• CI840 error on unit in position A

CI840 in position A is erroneous.

• CI840 error on unit in position B

CI840 in position B is erroneous.

• Redundant cable A failed

The Profibus cable to CI840 in position A is unconnected or broken.

• Redundant cable B failed

The Profibus cable to CI840 in position B is unconnected or broken.

Station address warning

There is a mismatch between the actual address on the CI840 and the one

configured in the system or if the address is set above 62. The warning will be

cleared when the system is restarted with the right configuration or if the switch on

the CI840 is changed back to the configured address.

Configuration

For configuration of the module, select the “Configuration” menu item. It shows the

user parameters for the FCI e.g. Output Hold Time.

This control is not available if the unit is used towards AC 800M. The

configuration data is then set via Control Builder Professional

Figure 24. CI840 - Configuration for AC870P

Sequence of Events

The Sequence of Events checkbox determines the status of the SOE feature in the

supported I/O modules:

• If this checkbox is checked, the SOE drop-down menu in the Channel

Parameters tab of the supported I/O modules is activated. The user can then

select the SOE status for each channel.

• If this checkbox is unchecked, the SOE is disabled for the supported modules,

and the SOE drop-down menu in the Channel Parameters tab of the supported

modules is not activated.

SOE is supported in DI825. DI830. DI831. and DI885 modules.

Power supervision of FCI

Mark the check box if the voltage supply to the FCI shall be supervised. Only if

redundant power supply.

• Power supervision of opto extension

Mark the check box if the voltage supply to the cluster shall be supervised.

Only if redundant power supply.

• Redundancy

Mark the check box if the CI840 shall be configured as a redundant module.

• Extended HART mode

Normal mode shall always be used if HART data is < 56 bytes. Mark the check

box if the HART data is > 56 bytes but < 215 bytes. If Extended HART mode

is chosen less I/O modules can be used. See Memory Maps for more details.

• Output hold time

After a fail over, a timer is started in the new primary CI840. This CI840

requires configuration and data from the Profibus Master within the output

hold time, which is defined in the Output hold time text field. If no data is

received within the defined time, the channels on the output modules are set to

the predefined value (OSP value).

• HCIR Enable

Hot Configuration In Run active

• HCIR Factor

Hot Configuration In Run Factor

• HCIR Watchdog

Hot configuration In Run Worst Case Bus Cycle Base

Configuration Control of DI825/DI830/DI831/DI885 with CI840 for SOE

To use the modules DI825/DI830/DI831/DI885 for SOE, open the

ServiceEntries.xml file, and set the value of the ‘EnableSOE’ attribute to 1.

The location of ServiceEntries.xml is

ABB800xAS800DTM. The ProgramData folder is hidden, by

default.

Table 3 describes the different configuration control options for the SOE supported

modules DI825. DI830/DI831 and DI885. used with CI840 for AC870P.

It is assumed that the EnableSOE attribute is set to 1 globally.

Table 3. Configuration control of SOE supported modules used with CI840. for

AC870P

Status of ‘Sequence of

Events’ checkbox in

CI840 Configuration

Control

Displayed status in the

‘SOE’ drop-down menu in

DI825/DI830/DI835/DI885

Configuration Control

Whether the displayed

SOE status in DI8xx

can be changed

Unchecked, by default,

after inserting the CI840

for the first time

SOE disable No

Checked after an

unchecked status

SOE disable Yes

  • Watlow Anafaze SYSTEM 32 Modular Industrial Process Controller
  • Watlow ANAFAZE 12LS type 1/8 DIN multi loop PID controller
  • Comprehensive analysis of NextMove ST motion controller
  • Baldor MotiFlex e100 Servo Drive Installation and Configuration Guide
  • Baldor FlexDrive II Servo Drive Technology Explanation and Application Guide
  • Baldor MicroFlex servo drive
  • ABB MicroFlex servo drive
  • Baldor BSM series AC servo motor
  • Baldor Reliability CDPT3320 DC Motor
  • Baldor-Reliance ® Super-E ® Efficient motor: full analysis of technological breakthroughs, standard adaptation, and industrial applications
  • Baldor-Reliance® Integral horsepower DC motors
  • Baldor sports product accessories
  • HIMA HICore 1 Assessment Kit
  • HIMA HIJunctionBox on-site distributed junction box
  • HIMA HIMatrix F35 Manual Safety-Related Controller
  • HIMA HIQuad X High Safety Modular Programmable Electronic System (PES)
  • HIMA HIMax High Safety Modular Programmable Electronic System (PES)
  • HIMA Planar4 Where Ultimate Safety Counts ​
  • How many units does WOODWARD Vertex's load distribution function support linkage, and what are the characteristics of configuration and communication?
  • WOODWARD Vertex Digital Control for Performance and Compressor Control
  • WOODWARD easYview miniSCADA visualization solution
  • The Woodward easyYview series is an HMI solution designed for users such as switchgear manufacturers
  • Woodward MicroNet ™ Plus modular digital control system
  • Woodward easYgen LS-6XT Multi-Breaker control for complex power management applications
  • Woodward easyYgen LS-6XT series circuit breaker control unit
  • WOODWARD LS-5 Series | LS-521 V2 Circuit Breaker Control
  • Woodward MicroNet TMR ® 5009 Digital Control System
  • Woodward MicroNet ™ Simplex/Plus digital controller
  • Woodward MSLC-2XT ™ Main synchronizer and load controller
  • Woodward DSLC Digital Synchronizer and Load Controller
  • Woodward DSLC-2 Digital Synchronizer and Load Controller
  • What are the core configuration points and networking capabilities of the Woodward easyYgen-3000 series CAN bus interface in load sharing scenarios?
  • Woodward easyYgen-3000 series (Package P1) generator set controller
  • Woodward ProTech SX Security System
  • Woodward ProTech-SX Simplex System
  • How does the Woodward QuickTrip electro-hydraulic trip block component ensure the reliability of critical applications?
  • WOODWARD QuickTrip Electro Hydraulic Trip Block Component (P/N: 9907-1248)
  • WOODWARD VariStroke Hydraulic Power Cylinders (VHPC) hydraulic power cylinder
  • WOODWARD VariStroke GI single acting electro-hydraulic actuator
  • WOODWARD VariStroke DX Skid Dual Redundant Hydraulic Servo System
  • WOODWARD VariStroke-I (VS-I) electro-hydraulic actuator
  • WOODWARD MicroNet TMR ® OpView of 5009 Digital Control System ™ Interface Operation Manual
  • WOODWARD 5009XT Fault-Tolerant Control
  • WOODWARD PG-PL Governor Installation and Operation
  • WOODWARD 2301A Speed Control Controller
  • XP POWER VFR05 series 5W wall mounted AC-DC power adapter
  • XP POWER VFL05 series AC-DC power adapter
  • XP POWER AQM200 series AC-DC external power supply
  • XP POWER CB Series DC-HVDC Converter
  • XP POWER CDX Series 1500W Dual Frequency RF Power Supply
  • XP POWER RDF25 Series 5W Bottom Cooling DC-DC Converter
  • XP POWER ITX Series 6W DC-DC Converter
  • XP Power Supply Technical Guide
  • XP POWER C Series Micro Stabilized High Voltage DC-DC Converter
  • XP POWER EHL05 Series AC-DC Power Supply
  • XP Power focuses on global solutions for power conversion
  • XP POWER HDA1500 Series AC-DC Power Supply
  • XP POWER SMP350 Series AC-DC Power Supply
  • XP POWER MP Series AC-DC Power Supply
  • YAMAHA RCX40 4-AXIS ROBOT CONTROLLER
  • HIMA X-AO 16 01 HIMax ® Analog Output Module
  • HIMA HIMax ® System Manual
  • Hirschmann Industrial Ethernet Switch
  • YASKAWA A1000 series AC frequency converter
  • HIRSCHMANN MACH1040 Series Full Gigabit Industrial Ethernet Reinforced Switch
  • Hirschmann MICE series media module and expansion module
  • Hirschmann MS20/MS30 series industrial Ethernet switches
  • Hirschmann Industrial Ethernet Switch Graphic User Interface (GUI) and Command Line Interface (CLI)
  • HIRSCHMANN MICE series
  • TOSHIBA TOSBERT VF-AS3 series
  • TOSHIBA MG08-D SERIES ENTERPRISE CAPACITY HDD
  • Triconex Triconex Tricon v9-v11 system
  • XYCOM XVME-100 memory module
  • ABB Ability™ Symphony® Plus MR Series
  • BENTLY 3500/15 AC and DC Power Supplies
  • HITACHI S10VE Programmable Controller
  • ABB SYNCHROTACT ® 5 synchronous devices
  • YASKAWA SGMCS series direct drive servo motor
  • YASKAWA GA700 series AC frequency converter
  • YASKAWA ∑ - V series AC servo drive
  • YASKAWA S-7 series linear servo
  • YASKAWA GA500 series AC micro frequency converter
  • YASKAWA 1000 series frequency converter
  • YASKAWA 120 Series I/O Modules
  • YASKAWA MEMOCON-SC 2000 series reversible counter module
  • YASKAWA Machine Controller MP2000 Series
  • Yaskawa VARISPEED-626M5 frequency converter
  • Yaskawa CP-9200SH Controller
  • WESTINGHOUSE eVinci ™ Micro reactor
  • WESTINGHOUSE HC series molded case circuit breaker
  • WESTINGHOUSE MAX-VH ™/ MAX-VHP ™ Series vertical hollow shaft induction motor
  • WESTINGHOUSE Alpha Plus Series Low Voltage Distribution System
  • WESTINGHOUSE Three Phase Induction Motors
  • WESTINGHOUSE iGen5000 Digital Inverter Generator
  • WESTINGHOUSE E510 series compact AC frequency converter
  • WESTINGHOUSE E-Series MCCB (Molded Case Circuit Breaker)
  • WESTINGHOUSE Transformer Product Line
  • Emerson Ovation OCR1100 Controller
  • BENDER Isolated Power Panels
  • Bender LifeGuard® LG2-Series Protection Panels
  • Bender LINETRAXX ® CTAC series AC measurement current transformer
  • Bender GPM series grounding power module
  • BENDER LINETRAXX® CTUB100 series
  • Bender LifeGuard ® LG2 series protective panel
  • BENDER ISOMETER ® Iso685 series
  • BENDER Greenlee 555C Electric Pipe Bending Machine
  • BENDER ISOMETER ® Iso685 (W) - D/- S insulation monitoring equipment
  • BENDER LINETRAXX ® VMD420 Three phase Voltage Frequency Monitor
  • BENDING 77 Series Electric Bender with Single Shoe Groups
  • BENDER EDS3090 series portable grounding fault location system
  • BENDER ISOSCAN ® EDS460/490-EDS461/491 series
  • Bender EDS3090/-91/-92/-96 series
  • SMC IRV10/20 series vacuum regulator
  • BMCM AMS42/84 5B amplifier system
  • ABB AFS series switches
  • NI VXIpc-870B Series Embedded Pentium III VXIbus Controllers
  • BENDER ISOMETER ® IRDH265/365 series insulation monitoring equipment
  • BENDER ISOMETER ® IRDH375 series Insulation Monitoring Equipment
  • BENDER WR70x175S (P)... WR200x500S (P) rectangular measuring current transformer
  • BENDER IRDH575 Insulation Monitoring Equipment (IT System)
  • BENDER IRDH575 Series Digital Ground Fault Monitor
  • BENDER RCMA475LY AC/DC sensitive residual current monitor
  • YOKOGAWA FIO I/O module with built-in safety barrier
  • YOKOGAWA YS100 series instrument
  • YOKOGAWA FCN/FCJ Autonomous Controller
  • YOKOGAWA AIP 830 Single Circuit Operation Keyboard
  • YOKOGAWA FIO System (compatible with Vnet/IP) Hardware Specification Manual
  • YOKOGAWA CENTUM VP Integrated Production Control System