WOODWARD 9907-1106 CPC-II Current-to-Pressure Converter

Product Overview
The WOODWARD 9907-1106 is a CPC-II Current-to-Pressure Converter developed for industrial hydraulic control applications. It converts an electrical current command into a proportional hydraulic pressure signal, allowing control systems to regulate the position of steam valves, fuel valves, and associated servo mechanisms. As part of the Woodward CPC-II product family, this converter combines electronic signal processing with an integrated hydraulic control mechanism to provide accurate and stable pressure regulation.
The 9907-1106 accepts a 4–20 mA input command and provides a control pressure range of 0–10 bar. Its maximum hydraulic supply pressure is 25 bar, making it suitable for installations where a relatively low control pressure is required from a higher-pressure hydraulic supply. The converter is designed to operate as an interface between an electronic turbine control system and the hydraulic equipment responsible for positioning mechanical valves.
In power generation and industrial process applications, accurate valve positioning is important for maintaining operating conditions and responding to changing control demands. The CPC-II provides an electrohydraulic conversion function that helps translate electronic controller commands into the hydraulic pressure required by the connected servo system.
Working Principle and Control Function
The operating principle of the WOODWARD 9907-1106 is based on converting an analog electrical current signal into a corresponding hydraulic output pressure. When the connected control system sends a 4–20 mA command, the internal electronic assembly processes the signal and controls the position of the hydraulic valve. The resulting pressure is supplied to the connected actuator or servo mechanism.
The CPC-II uses an integrated rotary three-way hydraulic valve and a brushless limited-angle rotary actuator. These components work together to regulate the hydraulic flow and establish the required control pressure. An internal pressure sensor provides feedback information to the electronic control system, supporting closed-loop pressure regulation.
This arrangement allows the converter to respond to changing command signals while maintaining the required hydraulic output. The pressure feedback function is particularly important in applications where stable actuator positioning and consistent valve operation are necessary. Its control characteristics can be adjusted according to the connected servo system and the requirements of the overall turbine control installation.
Technical Characteristics
The 9907-1106 is configured for a 0–10 bar control pressure range with a maximum hydraulic supply pressure of 25 bar. Its electrical command input is 4–20 mA, and the unit operates from a nominal 24 VDC power supply. The documented input voltage range is 18–32 VDC, allowing the converter to operate within the specified industrial DC power supply conditions.
The CPC-II incorporates an analog pressure feedback output and configurable discrete outputs for monitoring and control purposes. Its electronic assembly also provides a service interface for configuration, adjustment, and diagnostic activities. PC-based service tools can be used to access operating parameters and perform appropriate commissioning or maintenance procedures.
The converter uses an anodized aluminum housing and a manifold-mounted hydraulic interface. Its enclosure is rated IP66 according to the CPC-II installation and operation manual. The design provides protection for the internal electronic and hydraulic components in the specified industrial installation environment.
Hydraulic System and Installation Requirements
Proper hydraulic installation is essential for maintaining the performance of the 9907-1106. The converter connects to an external hydraulic supply, a tank or drain connection, and a control pressure line leading to the associated valve servo. These hydraulic connections are integrated through a suitable adapter block or manifold arrangement.
The CPC-II installation manual recommends mineral-based or synthetic-based hydraulic oils that meet the applicable Woodward fluid recommendations. An external serviceable supply filter is required, with a nominal filtration rating of 24–40 micrometers and a beta rating of 75. Hydraulic fluid cleanliness of ISO 20/16 or better is recommended for optimum reliability.
The recommended maximum control pressure should generally remain below 70 percent of the hydraulic supply pressure for optimum dynamic performance. Supply pressure stability should be maintained within the specified limits. Excessive drain pressure, contaminated hydraulic fluid, or unsuitable hydraulic piping can influence pressure regulation and overall system response.
For installation, the converter should be mounted on an appropriate adapter block or plate. Hydraulic interfaces, sealing arrangements, mounting screws, electrical wiring, and grounding should follow the manufacturer's instructions. The installation location should also provide adequate ventilation and avoid excessive vibration or unnecessary hydraulic line length.
Compatibility and Product Configuration
Woodward identifies the 9907-1106 as a CPC-II model with a 25 bar maximum hydraulic supply rating and a 0–10 bar control pressure range. Its documented area classification is Class I, Division 2 and ATEX Zone 2 for the applicable configuration. These characteristics should be considered when checking compatibility with an existing turbine control installation.
The CPC-II family includes several models with different supply pressure ratings, output pressure ranges, and hazardous-area classifications. Although these products share a common design platform, their specifications are not identical. The 9907-1106 should therefore be distinguished from models such as 9907-1102, 9907-1103, and 9907-1100 when selecting a replacement or planning a system upgrade.
The original CPC-II documentation also identifies 9907-1106 as a replacement for certain earlier CPC converters, including models 8901-455, 8901-457, and 8901-459, when the specified pressure range and area classification requirements are satisfied. Installation dimensions, hydraulic interfaces, electrical connections, and application requirements should be verified before changing an existing configuration.
Industrial Applications
The WOODWARD 9907-1106 is designed for applications requiring electrohydraulic pressure conversion and accurate actuator positioning. Typical installations include steam turbine control systems, industrial gas turbine auxiliary systems, fuel valve positioning equipment, and hydraulic servo control assemblies.
In steam turbine applications, hydraulic pressure is commonly used to operate valve actuators that regulate steam flow. The CPC-II converts electronic control commands into hydraulic pressure signals that correspond to the required valve positioning demand. A similar control arrangement can be used in fuel valve systems and other industrial machinery where an electronic controller operates a hydraulic actuator.
The converter is also relevant to industrial facilities maintaining existing Woodward turbine control equipment. Its modular construction and service interface support inspection, troubleshooting, commissioning, and component replacement activities within compatible hydraulic control installations.
Maintenance and Troubleshooting Considerations
Regular inspection of the electrical and hydraulic connections is important for maintaining stable CPC-II operation. Maintenance personnel should examine the hydraulic supply condition, filter performance, drain pressure, electrical power supply, and signal wiring. Abnormal pressure feedback, unstable valve positioning, or inconsistent output response may indicate problems involving the hydraulic system, sensor feedback, electrical connections, or internal control components.
During commissioning or troubleshooting, the input command signal and measured hydraulic output pressure should be compared with the expected operating values. The service interface can be used by qualified personnel to review the converter's operating parameters and diagnostic information. Any adjustments to control dynamics or operating limits should follow the applicable Woodward documentation and approved engineering procedures.
Because the CPC-II is used in turbine valve and fuel control applications, maintenance work must be performed under appropriate machinery safety conditions. Hydraulic pressure should be isolated where required, and the controlled equipment should be placed in a safe state before inspection or adjustment.
Conclusion
The WOODWARD 9907-1106 CPC-II Current-to-Pressure Converter is an electrohydraulic control device designed to convert 4–20 mA electrical commands into proportional hydraulic pressure. With a 0–10 bar control pressure range and a maximum supply pressure of 25 bar, it provides an interface between electronic turbine controllers and hydraulic valve servo systems.
Its integrated rotary hydraulic valve, brushless actuator, electronic control assembly, and pressure feedback function make it an important component in compatible industrial valve positioning applications. Understanding its hydraulic specifications, electrical requirements, mounting configuration, and area classification is essential when selecting this model for existing Woodward CPC-II installations or planning equipment maintenance.