HIMA HIMatrix DO 8 01 Safety Digital Output Module
The HIMA HIMatrix DO 8 01 is a safety-related digital output module designed for the modular HIMatrix F60 safety controller system. Identified by part number 98 2200112, the module provides eight relay output channels for switching external circuits in industrial safety applications. It is equipped with safety-related relay contacts and integrated diagnostic functions designed to support dependable operation in safety control installations.
The DO 8 01 is used in applications where safety control logic must operate external equipment such as shutdown circuits, contactors, control devices and other compatible electrical loads. Its relay-based output architecture provides potential-free normally open contacts, allowing the switching circuit to be arranged according to the requirements of the connected equipment.
Product Overview
HIMatrix F60 is a modular safety-related controller platform used in industrial process and machine safety applications. The system consists of a central processing module, power supply and configurable input and output modules. The DO 8 01 provides the digital output functionality within this modular architecture.
The module contains eight independent relay output channels. Each output is equipped with two safety relays with forcibly guided contacts and one standard relay. This relay arrangement is designed for safety-related switching functions and allows the system to monitor output behavior through the corresponding internal diagnostic mechanisms.
The output status is displayed through LEDs located on the front panel. These indicators provide visual information about the operating state of individual channels and help maintenance personnel identify the status of the module during system operation or troubleshooting.
Safety-Related Digital Output Functions
The HIMA DO 8 01 is designed to transmit switching commands from the safety controller to connected equipment. In a safety application, the output channels can be used to control devices that perform shutdown, isolation or other safety-related actions according to the configured safety logic.
The forcibly guided relay contacts provide a defined mechanical relationship between relay contacts, allowing the module's internal monitoring arrangements to detect certain relay-related faults. If a fault is detected in an output channel, the affected output can be switched to the safe de-energized state. If a module fault occurs, the module can switch all digital outputs off according to its fault reaction design.
The module is certified for safety-related applications up to SIL 3 according to IEC 61508, IEC 61511 and IEC 62061, as well as Cat. 4 according to EN 954-1 and PL e according to EN ISO 13849-1, subject to the applicable system conditions and safety requirements.
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | HIMA Paul Hildebrandt GmbH |
| Product Series | HIMatrix F60 |
| Model | DO 8 01 |
| Part Number | 98 2200112 |
| Product Type | Safety-Related Digital Relay Output Module |
| Number of Outputs | 8 |
| Output Type | Potential-Free Normally Open Relay Contacts |
| Relay Configuration | Two Forcibly Guided Safety Relays and One Standard Relay per Output |
| Switching Voltage | 6 V minimum to 250 VAC / 250 VDC maximum |
| Switching Current | 10 mA minimum to 3 A maximum |
| Internal Fuse | 3.15 A |
| Maximum AC Switching Capacity | 400 VA at cos phi ≥ 0.5; 600 VA at cos phi = 1, up to 250 VAC |
| DC Switching Capacity | Load-dependent; refer to the applicable technical specifications |
| Power Supply | Central F60 Power Supply Module |
| Operating Temperature | 0 to +50 degrees C under standard operating conditions |
| Storage Temperature | -40 to +85 degrees C |
| Installation | HIMatrix F60 Modular Rack |
| Available Slots | Slots 3 to 8 |
| Safety Certification | Up to SIL 3, Category 4 and PL e, subject to applicable requirements |
| Protection | IP40 module; terminal connections IP20 |
The technical values listed above are based on the DO 8 01 hardware documentation. Switching capacity and operating limits depend on the connected load, application conditions and applicable certification requirements. The load circuit must be designed within the specified limits.
Relay Output Architecture
Each digital output channel uses a relay-based switching arrangement. The output contacts are potential-free, allowing the connected external circuit to be arranged according to the electrical requirements of the application. The module's relay configuration includes forcibly guided safety relays and a standard relay associated with each output channel.
The relay contacts are suitable for switching compatible electrical loads in safety control applications. When switching direct-current loads, the external circuit must be equipped with suitable protective components and fusing according to the electrical design. Inductive loads may require additional suppression to limit switching transients and protect the relay contacts.
The output circuits should be designed according to the specified voltage, current and switching capacity limits. The contact rating is not the same for every load type, and the permitted switching capacity varies with AC or DC operation, load characteristics and applicable safety requirements.
LED Indicators and Diagnostics
The DO 8 01 includes RUN and ERR status indicators together with eight individual output LEDs. These indicators help identify the module operating state and the switching condition of each output channel.
RUN LED: Indicates the presence of operating voltage and the module operating condition.
ERR LED: Indicates a module fault or an external fault condition detected by the diagnostic system.
Channel LEDs 1 to 8: Indicate the active or energized status of the corresponding relay output.
The module provides diagnostic information through the controller programming environment. Channel and module error codes can be reviewed using the supported engineering software. These diagnostics may indicate output readback faults, relay status discrepancies, configuration problems or other module-related conditions.
When an output fault is detected, the corresponding output can be switched to its safe de-energized state. If a module-level fault occurs, all outputs may be deactivated according to the module's documented fault reaction. The final safety response also depends on the configured application logic and system architecture.
Installation in the HIMatrix F60 System
The DO 8 01 is designed as a plug-in module for the modular HIMatrix F60 rack. The F60 rack reserves slot 1 for the power supply module and slot 2 for the CPU module. I/O modules can be installed in the available positions from slot 3 through slot 8.
The module is configured using the applicable HIMA programming environment. Depending on the controller operating system version, configuration may be performed using SILworX or ELOP II Factory. The module configuration includes assigning application signals to the individual digital output channels.
During installation, the module must be correctly positioned in the rack and connected according to the system wiring documentation. The output terminal arrangement provides two terminals for each relay contact, allowing the eight output circuits to be connected individually.
Industrial Applications
The HIMA HIMatrix DO 8 01 is used in safety-related automation systems where relay outputs are required for control or protective actions. Its eight output channels provide switching interfaces for external equipment in industrial process and machinery applications.
Emergency Shutdown Systems: Switching external shutdown circuits according to the configured safety logic.
Process Safety Systems: Output signals for safety-related control and interlock functions.
Industrial Machinery: Switching contactors and other compatible control devices.
Power Generation: Control and protective output circuits within safety-related installations.
Petrochemical Facilities: Relay-based safety outputs for compatible process equipment and protective functions.
Plant Protection Systems: Activation of external devices according to safety controller commands.
Maintenance and Replacement Considerations
Before replacing the DO 8 01, verify the product designation, part number and hardware revision against the installed system documentation. The replacement module must be compatible with the HIMatrix F60 rack, application configuration and required safety function.
The module must only be removed or installed when the relevant system components are powered down. HIMA documentation states that modules may not be removed or inserted during operation. Maintenance personnel should follow the approved site procedures and take appropriate electrostatic discharge precautions.
After replacement, the controller configuration, output assignments, diagnostics and connected circuits should be checked. The required proof testing and safety verification activities must be performed according to the installation's maintenance plan and safety requirements.
Related HIMatrix Modules
The HIMatrix F60 modular system supports different input, output and system modules. Related products include:
F60 CPU 01: Central processing and communication module.
F60 PS 01: Power supply module.
AI 8 01: Analog input module.
AO 8 01: Analog output module.
DI 32 01: Digital input module with 32 channels.
DIO 24/16 01: Digital input/output module.
DO 8 01: Eight-channel safety-related relay output module.
Each module performs a specific function within the HIMatrix F60 system. Selection and replacement should be based on the required I/O type, controller configuration, safety function and the corresponding hardware documentation.
Conclusion
The HIMA HIMatrix DO 8 01, part number 98 2200112, is an eight-channel safety-related digital relay output module for the modular F60 controller system. Its potential-free normally open relay contacts and forcibly guided safety relay arrangement provide switching interfaces for industrial safety applications.
With individual channel indicators, module diagnostics and support for configuration through HIMA engineering tools, the DO 8 01 provides output control and status information within a HIMatrix safety control architecture. Correct selection, installation, configuration and maintenance are essential to ensure that the module operates according to the requirements of the overall safety system.