K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
Honeywell Controller C30 CPU 900C30-0360-00
❤ Add to collection

Honeywell Controller C30 CPU 900C30-0360-00

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

The module is in the failsafe state

because it is not receiving message

requests from the CPU or Scanner

at a rate that satisfies the configured

failsafe timeout.

19000.00
¥19000.00
Weight:3.550KG
Quantity:
(Inventory: 99)
Consultation
Accessories
  • ABB-Binary I/O m
    Original :¥15774.00
    With a price :¥15774
    Quantity  
  • ABB-Optical star
    Original :¥9993.00
    With a price :¥9993
    Quantity  
  •   
    Original :¥
    0.00
      
      With the total price :¥
    0.00
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

The module is in the failsafe state

because it is not receiving message

requests from the CPU or Scanner

at a rate that satisfies the configured

failsafe timeout.




Honeywell Controller C30 CPU 900C30-0360-00

Bad module details
When an I/O module’s error status is BAD MODULE, the module’s status LED on the controller is flashed
red with a number of quick strobes followed by a long off time. Table 23 outlines the potential module
diagnostics.
Table 23 Bad module details
Number of
Strobes
Failure Description AI AO DI DO PFQ User Action
Contact AC DC Relay AC DC
1 FAIL SAFE The module is in the failsafe state
because it is not receiving message
requests from the CPU or Scanner
at a rate that satisfies the configured
failsafe timeout.
√ √ √ √ √ √ √ √ √ 1. If expansion I/O rack, go to step 2. If
no expansion I/O rack, go to step 3.
2. Check the Scanner status LED (see
Scanner Indicators in HC900
Process Controller manual, #51-52-
25-107).
If it’s flashing 6 times, proceed
with step 3.
If it’s flashing some other red
status code (refer to Scanner
Indicators in HC900 Process
Controller manual, #51-52-25-107)
to solve that problem first.
If it’s flashing green, the module
probably is not required in the
configuration.
If it’s not on or steady, cycle
power to the scanner.
3. Make sure the module is the correct
one for the configuration.
4. Remove the module and check for
a bent pin, then reinsert the module
5. Replace the module
6. Remove other modules and replace
one at a time until the problem
reoccurs. Most likely the last module
inserted needs to be replaced.
7.Replace the rack.
2 EAROM EA ROM Failed its checksum √ √ 1. Remove/reinsert module.
2. Replace module.
3 RAM √ √ √ √ √ √ √ √ √
4 ROM √ √ √ √ √ √ √
5 +24 V √ √ √ √ 1. Remove the module and check
for a bent pin, then reinsert the
module
2. Measure power supply voltage. If
not correct, replace power supply.
3. Replace module
4. Replace rack
6 FACTORY CAL CRC failure of primary and backup
factory calibration
√ √ Replace module.
7 FIELD CAL CRC failure of field calibration
values
√ √ 1. Remove/reinsert module.
2. Replace module.
8 HARDWARE General Hardware Failure
(AI=convertor not working)
√ Replace module.
9 HW/SW Key The software residing on the
module does not match the module
type. This diagnostic should only
result in the factory.

√ √ √ √ √ Replace module

Number of

Strobes
Failure Description AI AO DI DO PFQ User Action
Contact AC DC Relay AC DC
11 Shift Register The loopback test of the shift
register failed.
√ √ √ √ √ √ Replace module
Bad channel details
Below is a list of conditions that can cause a BAD CHANNEL I/O module diagnostic.
Table 24 Bad Channel details
I/O Summary Error Status Description What to do
Bad Channel If the channel is an Analog Output: There is no
physical output device connected to this
channel, or the output device is showing an
open connection.
If the channel is a Pulse Output: The channel is
failing to output the correct value.
A BAD CHANNEL I/O module diagnostic is
posted.
Check terminal block
connections.
Replace module.
Burnout Fail The sensor – T/C, RTD, or mV source -- is
failing burnout checks. A BAD CHANNEL I/O
module diagnostic is posted.
Check terminal block connections
Replace source element
Replace module.
Convert Fail When attempting to take a reading, the analogto-digital (ADC) fails. This can occur if the
incoming signal is either too large or too small.
It also could result if the ADC circuit is failing. If
the problem is the ADC circuit, most likely other
channels will have the same failure. A BAD
CHANNEL I/O module diagnostic is posted.
Check the signal level being
applied to the terminals.
Replace module.
No Channel There is no hardware on the I/O module to
support this channel. For example, the
customer configured Channel #15 for a given
module, but there is an 8-channel module
installed in the rack. A BAD CHANNEL I/O
module diagnostic is posted.
Over Current A Digital Output module detected an excessive
amount of current on its output terminals. Note
that this message will only appear for the 32-
channel DO module. A BAD CHANNEL module
diagnostic is posted.
  • Atlas Copco ACTA4000/3000 is a portable torque analysis and calibration instrument
  • Atlas Copco Tensor STB Wireless Tightening Tool
  • Atlas Copco PF4000 Setup Guide
  • Atlas Copco Power Focus 6000 Pocket Guide
  • Atlas Copco ZR-ZT 110-275/132-315 VSD oil-free screw air compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Swipe Controller
  • Atlas Copco Tensor ES electric tightening tool paired with Power Focus 600 controller
  • ADLINK STC2-AL/KL series intelligent touch computer
  • ADLINK STC-15W04 industrial touch all-in-one machine
  • ADLINK SP2- EHL series fanless open panel PC
  • ADLINK PXIS-2719A 19 slot 3U PXI chassis
  • ADLINK PXIe-9908 8-channel four quadrant high-density source measurement unit SMU (Source Measure Unit) PXIe module
  • ADLINK PXIe-9852 2-channel 14 bit, up to 200 MS/s synchronous sampling PXIe high-speed digitizer
  • ADLINK PXIe-9848 8-channel 14 bit, up to 100MS/s synchronous sampling PXIe high-speed digitizer
  • ADLINK PXIe-9834 4-channel 16 bit, up to 80MS/s synchronous sampling PXIe digitizer
  • ADLINK PXIe-9529H is an 8-channel 24 bit, 256kS/s synchronous sampling dynamic signal acquisition PXIe module
  • ADLINK PXIe-3988 3U PXI Express Zero Slot Embedded Controller
  • ADLINK PXIe-3987/3977/3937 PXI Express Zero Slot Embedded Controller
  • ADLINK PXIe-3987 PXI Express Embedded Controller
  • ADLINK PXIe-3988/3987/3977/3937-TL PXI Express Embedded System Controller
  • ADLINK PXI-2020/PXI-2022 Synchronous Sampling Multi functional PXI Data Acquisition Card
  • ADLINK DAQ-20XX/PXI-20XX series 4-channel synchronous multifunctional data acquisition card
  • ADLINK PXES-2788 series high-performance and high-power PXIe chassis
  • ADLINK PXES-2785 18 Slot PXI Express Chassis
  • ADLINK PXES-2780 18 Slot PXI Express Chassis
  • ADLINK PXES-2596 Gen3 9-slot PXI Express chassis
  • ADLINK PXES-2590 9-slot PXI Express chassis
  • ADLINK PXES-2314T Thunderbolt 3 Compact 4-slot PXI Express Chassis
  • ADLINK PXES-2301 6-slot PXI Express chassis
  • ADLINK PCIe U300 series USB3 Vision image acquisition host card
  • ADLINK PCIe PXIe 8565 PCIe to PXIe Remote Expansion Kit
  • ADLINK PCIe GIE74V 4-channel GigE Vision acquisition card
  • ADLINK PCIe - GIE7x Series PCIe x4 Interface GigE Vision PoE+Gigabit Network Image Capture Card
  • ADLINK PCIe CPL64V PCIe Gen3 x4 specification Camera Link image acquisition card
  • ADLINK PCIe CPL64 PCIe x4 Interface Camera Link Image Capture Card
  • ADLINK PCIe 8560+PXI 8565 PCI Express to PXI Remote Bus Expansion Kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Master Station Motion Controller
  • ADLINK PCIe 7432 bus industrial isolated digital I/O board
  • ADLINK PCIe 7256 Industrial Digital I/O Board
  • ADLINK PCIe‑833x(PCIe‑8332 / 8334 / 8338)PCIe EtherCAT Master Motion Controller
  • ADLINK PCIe -10GPoE Dual Channel PCIe Gen3 PoE+10GigE Vision Image Acquisition Card
  • ADLINK PCI-8254/PCI-8258 High end 4/8-axis Advanced Motion Control Card
  • ADLINK PCI-8158/PCI-8154 Modular Architecture Advanced Pulse Motion Control Card
  • ADLINK PCI-8134A entry-level 4-axis pulse servo/stepper motion control card
  • ADLINK PCI-725X Series Relay Output and Isolation Digital Input Board
  • ADLINK PCI-6308 series isolated analog output board
  • ADLINK PanKonix ® Series industrial HMI all-in-one machine
  • ADLINK NuDAM-6100 series DIN rail installation, RS-485 bus distributed IO module
  • ADLINK NuDAM-6000 complete distributed RS-485 acquisition and control system
  • ADLINK NEON-2000-ONO series AI intelligent camera
  • ADLINK NuDAM-65xx Communication Module
  • ADLINK NuDAM-60xx Series Digital I/O Modules
  • ADLINK MXE-5300 series fanless embedded computer
  • ADLINK MXE-310 Series Rugged and Compact edge computing Device
  • ADLINK MXE ‑ 230 series ultra compact fanless Alder ‑ Lake ‑ N platform industrial edge computer
  • ADLINK MXE-210 series fanless X86 embedded industrial computer
  • ADLINK MXC-3300/MXC-3340 Fanless Scalable Embedded Industrial Computer
  • ADLINK MXA-312M Ultra Compact Edge AI Computer User Manual
  • ADLINK MXA-200 Industrial IoT Energy Gateway
  • ADLINK MVP-6200 series fanless expandable industrial computer
  • ADLINK MVP-6100 series expandable fanless industrial computer
  • ADLINK MVP-5200 series fanless industrial computer
  • ADLINK MVP-5100 series fanless industrial computer
  • ADLINK MVP-3100 series fanless embedded machine
  • ADLINK MNET-J3/S23/MIA/DA2/SAN single axis Motionnet distributed motion module
  • ADLINK MNET-4XMO/MNET-4XMO-C distributed 4-axis motion control module
  • ADLINK MCM-216/MCM-218 Independent Ethernet Distributed Device Status Monitoring DAQ
  • ADLINK LPCIe-8124-C 4-channel high-speed trigger encoder acquisition card
  • ADLINK IM/OM series industrial touch display
  • ADLINK GW-01 is compatible with PLC industrial IoT gateway
  • EURESYS Grablink Full Series Image Acquisition Cards
  • ADLINK Express HL COM Express Type6 Core Module
  • ADLINK EOS-2000 4-channel analog embedded visual controller
  • ADLINK EOS-1200 4-channel Gigabit PoE Embedded Vision System
  • ADLINK ECS-8582-4S ExpressCard to PCI Expansion System Manual
  • ADLINK DIN-814P-A4 4-axis dedicated motion terminal board
  • ADLINK DIN-814M-J3A 4-axis dedicated motion adapter terminal board
  • ADLINK DIN-814-GP Reference Guide
  • ADLINK DIN-812M Terminal Block Installation Manual
  • ADLINK DIN-814Y Terminal Board
  • ADLINK DAQ/DAQE/PXI-250x series multifunctional analog output acquisition card
  • ADLINK DAQ/DAQE/PXI-220x series multifunctional acquisition card
  • ADLINK cPCI-9116 3U CompactPCI 64 channel 16 bit 250KS/s analog acquisition card
  • ADLINK cPCI/PCI-8554+R multifunctional counting/timing card
  • ADLINK 743X series isolated digital IO board
  • ADLINK cPCI-3534/cPCI-3544/cPCI-3538 series serial port module
  • ADLINK cPCI-3534/3544/3538 series CompactPCI serial port module
  • Euresys Coaxlink Full Series CoaXpress Image Capture Cards
  • ADLINK AMP-304C High end 4-axis Pulse Motion Control Card
  • ADLINK AMP-104C Four Axis Pulse Motion Control Card
  • ADLINK NEON-1020/NEON-1040 Smart Camera
  • ADLINK USB-7230/USB-7250 Isolated Digital I/O Module
  • ADLINK SP-15W03 15.6-inch intelligent all-in-one machine
  • ADLINK DIN-825-4P0 Terminal Board
  • ADLINK USB/LPCI/LPCIe-3488A GPIB interface card
  • ETEL TMB+series standard torque motor
  • ADLINK Angelo RTV series multi-channel real-time video capture card
  • ADLINK PCIe FIW Series 1394b Image Acquisition Card
  • ADLINK 6208/6216-GL series analog output card
  • ADLINK PCI/cPCI -/LPCI -/LPCIe-723X series 32 channel isolated digital I/O board
  • ADLINK PCI-9118 series multifunctional DAQ card
  • ADLINK PCI-9114 (A) Multi functional PCI Data Acquisition Card
  • ADLINK PCI-7440 series (PCI-7442/7443/7444) high-density isolated digital I/O cards
  • ADLINK PCI/LPCI/LPCIe/cPCI-7250 series relay isolation digital IO board
  • Advantech PCI-1610 Series 4-port RS232 PCI Serial Port Card
  • ADLINK NEON-1000-MDX series AI intelligent camera
  • ADLINK MXE-1300 series industrial fanless industrial control computer
  • ADLINK MXE-200/200i Fanless Embedded Computer
  • ADLINK LPCIe/LPCI/USB-3488A GPIB interface card
  • ETEL Linear Motors Product Manual
  • ETEL IL+Ironless/LM Iron Core Linear Motor
  • ETEL DSC Series (DSC2P/DSC2V/DSCDP/DSCDL/DSCDM) Operation and Software Manual
  • ETEL DSCDL Dual Axis Digital Direct Drive Controller Hardware Manual
  • ETEL DSB2-P Digital Servo Amplifier
  • ETEL DSC Series Digital Position Controller Operating Software Manual
  • DFI HD636-H81CS ATX Industrial Motherboard
  • ADLINK DAQ/DAQE/PXI-20xx series multifunctional synchronous acquisition card
  • ADLINK cPCI-6530 series 6U CompactPCI single board computer
  • ADLINK cPCI-3610 Series 3U CompactPCI Single Board Computer
  • ADLINK AMP-204C/AMP-208C Motion Control Card
  • ADLINK AmITX-ALN-N97 Mini ITX Industrial Motherboard
  • ADLINK NuPRO-850 Full length ePCI-X Industrial Control Board
  • ADLINK MI-965 Mini ITX Industrial Motherboard
  • ADLINK M-302 ATX Industrial Motherboard
  • ADLINK PXI-3920/PXI-3910 3U PXI System Controller
  • ADLINK PCI-8132 Two Axis Servo/Stepper Motion Control Card
  • ADLINK cPCI-6760D 6U CompactPCI Single Board Computer