WOODWARD 8444-1067 MFR 300 Multifunction Relay

Product Overview
The WOODWARD 8444-1067 is a multifunction relay associated with the Woodward MFR 300 series. Woodward product change documentation identifies this part number as MFR300-75M/WK0300. The MFR 300 is designed to combine electrical measurement, system monitoring, and configurable relay functions in a compact device for power generation and electrical distribution applications.
Unlike a conventional single-purpose relay, a multifunction relay can collect several electrical operating values and use configured monitoring functions to generate output signals. These capabilities allow the device to support generator-related supervision, electrical system monitoring, and communication with higher-level control equipment. Its role depends on the selected device configuration and the application parameters programmed during commissioning.
The MFR 300 platform is intended for integration into electrical power systems where reliable measurement and monitoring are required. It can provide information about voltage, current, frequency, and calculated power values. Configurable relay outputs can be assigned to supported monitoring or signaling functions, allowing the device to interface with other control and protection equipment.
Electrical Measurement and Monitoring
A central function of the MFR 300 is the acquisition and processing of electrical measurements. Voltage measurement inputs monitor the connected electrical system, while current measurement inputs receive signals from suitable current transformers. The controller processes these measurements to determine important operating values for the monitored system.
Depending on the configuration, the MFR 300 can calculate real power, reactive power, apparent power, and power factor. These values help operators and supervisory controllers understand generator loading and electrical operating conditions. Voltage and current information can also be used as the basis for configured monitoring functions.
Measurement accuracy and operating limits depend on the selected device version, current transformer ratio, voltage connection, wiring arrangement, and parameter settings. Correct scaling is essential when the relay is integrated into a generator panel or other electrical monitoring installation. Current transformer secondary ratings and voltage input arrangements must be checked against the applicable product documentation.
Multifunction Relay Outputs
The MFR 300 provides configurable relay outputs for signaling and control purposes. These outputs can be assigned to supported functions according to the application configuration. Depending on the selected settings, relay contacts may be used to communicate operating states, alarms, or monitoring conditions to external equipment.
The MFR 300 wiring documentation identifies five isolated relay outputs. One of these outputs is designated as a fixed Ready for Operation signal in the documented arrangement. The remaining relay assignments depend on the configured application and supported device functions. This arrangement gives system designers several options for connecting the relay to generator control panels, annunciation systems, and other electrical equipment.
Relay assignment should always be checked against the actual configuration file and wiring diagram. A relay output should not be assumed to perform a particular trip, alarm, or breaker-control function merely because it is available on the device. The intended logic, contact behavior, external interlocks, and downstream equipment requirements must be verified before the outputs are connected to an operating system.
Communication and Control System Integration
Communication is an important feature of the MFR 300 platform. The series supports integration with supervisory control equipment through communication protocols such as CANopen and Modbus, subject to the device version and configured protocol options. These interfaces allow electrical measurement information and supported device data to be exchanged with a PLC or other compatible control system.
The MFR 300 wiring documentation identifies an isolated RS-485 interface and a CAN bus connection. These interfaces support communication arrangements defined by the applicable hardware and software configuration. The selected protocol, communication parameters, data mapping, and controller settings must be compatible with the connected equipment.
For applications requiring centralized monitoring, the relay can provide electrical operating information to a higher-level control system. This can help operators monitor generator output and system conditions without relying exclusively on local panel indications. The exact data available through a communication interface depends on the configured device and its applicable protocol mapping.
Configuration and Service Interface
The MFR 300 is configured using Woodward's Toolkit software and the appropriate device-specific tool file. The software provides access to supported parameters and configuration functions. Correct configuration is necessary to ensure that measurement scaling, monitoring limits, relay assignments, and communication settings match the electrical installation.
A dedicated service interface is provided for connection to a computer using the appropriate Woodward configuration cable. The MFR 300 documentation describes USB and RS-232 configuration cable options. The USB configuration interface is associated with Woodward part number 5417-1251. The correct cable and software tool should be selected for the particular relay and service procedure.
Configuration work should be performed by personnel familiar with the generator protection and electrical control system. Before changing parameters, the existing settings should be documented. Incorrect measurement ratios, monitoring thresholds, relay assignments, or communication settings can affect the behavior of the connected electrical system.
Power Supply and Wiring Considerations
The MFR 300 installation documentation specifies a DC power supply connection with an operating input range of 8 to 32 VDC. The wiring diagram identifies the positive supply connection and the 0 VDC terminal. The supply voltage and polarity must be checked before the device is energized.
Voltage and current measurement connections require particular attention. The applicable wiring diagram defines the measuring input terminals and their connection arrangements. Current transformer secondary circuits must be installed and handled according to electrical safety procedures. Incorrect wiring or an unsuitable transformer ratio can lead to inaccurate measurements and improper monitoring behavior.
The device also provides communication and relay terminal connections. Installation personnel should verify terminal numbering, conductor routing, shielding requirements, grounding arrangements, and external circuit ratings against the relevant Woodward documentation. The wiring diagram for the exact MFR 300 configuration should take priority over generic descriptions of the product family.
Applications in Power Generation Systems
The WOODWARD MFR 300 series is used in electrical power systems that require measurement and monitoring of generator or grid-related operating conditions. Typical applications include generator control panels, distributed power generation installations, and electrical systems that exchange measurement data with PLC-based supervisory controllers.
In generator applications, voltage, current, frequency, and calculated power values provide useful information about electrical performance. Monitoring functions can help identify conditions that require an alarm or a configured relay response. Communication with higher-level controllers allows the measurement data to become part of a wider power management strategy.
The MFR 300 can also be used in renewable and distributed generation arrangements where electrical values need to be monitored by a central controller. The appropriate functions depend on the installed configuration, communication protocol, and application requirements. The device should be selected and programmed according to the electrical system design rather than relying only on its general product description.
Technical Specifications
| Manufacturer | Woodward |
|---|---|
| Part Number | 8444-1067 |
| Product Identification | MFR300-75M/WK0300 |
| Product Series | MFR 300 |
| Product Type | Multifunction Relay and Measuring Transducer |
| DC Power Supply | 8–32 VDC |
| Voltage Measurement | Three-phase voltage measurement inputs |
| Current Measurement | Three-phase current measurement inputs |
| Relay Outputs | Five isolated relay outputs in the documented MFR 300 wiring arrangement |
| Communication Interfaces | RS-485 and CAN bus |
| Supported Protocols | CANopen or Modbus, depending on configuration |
| Configuration Software | Woodward Toolkit |
| Configuration Interface | Woodward DPC service cable, USB or RS-232 options |
| Configuration Cable Reference | 5417-1251 USB configuration interface |
| Technical Documentation | Woodward MFR 300 Series Manual B37938 / 37538 |
Model Identification and Replacement Information
Woodward product change documentation identifies 8444-1067 as MFR300-75M/WK0300 and lists it among discontinued items. The same document identifies 8444-1092, described as MFR300-75M, in the replacement item listing. This information is useful when researching the product history and planning maintenance of installations using the earlier part number.
However, the appearance of a replacement item in a product change document does not automatically establish that every installation can accept the replacement without modification. The WK0300 suffix may identify a particular configuration or ordering arrangement. Before selecting a replacement, compare the complete product identification, hardware revision, application configuration, communication protocol, terminal assignments, and existing system requirements.
For an existing installation, it is recommended to record the complete nameplate information and review the configured parameters before replacing the relay. Particular attention should be given to voltage and current measurement scaling, relay functions, communication settings, and the configuration file used by the supervisory controller.
Conclusion
The WOODWARD 8444-1067 is an MFR 300 multifunction relay identified as MFR300-75M/WK0300. It combines electrical measurement, monitoring, configurable relay outputs, and communication capabilities for power generation and electrical system applications. Its measurement and communication functions make it suitable for integration with generator panels and compatible supervisory control systems.
For maintenance, replacement, or system integration, the exact device configuration should be verified using the nameplate, wiring documentation, and Woodward configuration files. Consulting the MFR 300 technical manual helps ensure that electrical connections, measurement settings, relay assignments, and communication parameters are appropriate for the installation.