K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
KOLLMORGEN-RCU501Remote Controller Unit
❤ Add to collection

KOLLMORGEN-RCU501Remote Controller Unit

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

RCU501 is a high performance, general purpose, real-time process control computer for use in a  wide variety of system applications in both on- and offshore installations. The processor core is  an embedded Power PC™ architecture and the module is approved for Ex Zone 2 applications

34385.00
¥33994.00
Weight:4.500KG
Quantity:
(Inventory: 40)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

RCU501 is a high performance, general purpose, real-time process control computer for use in a  wide variety of system applications in both on- and offshore installations. The processor core is  an embedded Power PC™ architecture and the module is approved for Ex Zone 2 applications


KOLLMORGEN-RCU501Remote Controller Unit

Application types • Dynamic Positioning Systems • Thruster Control / Steering Systems • Navigation Sensor Integrator • Integrated Process Control Systems • Alarm and monitoring Systems • Safety Systems Function • Dual ethernet LAN process networks • Dual RedundancyNet interface for  redundant RCU confi guration • Dual Remote IO process BUS (RBUS)  • 4 general purpose Digital Input channels • 4 general purpose Digital Output  channels • 32 serial lines for 3rd party interface • 2 PROFIBUS channels for 3rd party  interface • 2 CANBUS channels for 3rd party  interface Feature • Single unit topology: SIL 1 compliant • Dual unit topology: SIL 2 and SIL 3  compliant • Triple unit topology • Ex Zone 2 approved • Compliant to the following protocols: 1. Modbus (Serial and TCP) 2. NMEA 0183 3. PROFIBUS/PROFIsafe  4. CAN/DeviceNet • 3rd party vendor specifi c protocols are  available upon request • Power: 1. Redundant power input with power  alarm monitoring 2. Inrush current and over-voltage  protection • Enhanced watchdog with fail-safe  function and system status output Benefi ts The following built-in functions  minimize system downtime: • Extended Built-in Self- Test (BIST)  for computer diagnostics and fault  identifi cation during start-up and runtime • Prepared for online remote diagnostics • Prepared for online fi rmware upgrade  • Bootable from fi le server or local fl ash  memory • Easy installation and replacement 1. DIN Rail mounting 2. All connections are pluggable 3. 3 digit address switches • Hot swap in redundant applications, dual and triple Hot-Standby redundancy,  1oo2 redundancy  • Status LED indication (Normal/Error) • RoHS compliant Computer performance • RCU501 performance is application  dependant and governed by process  complexity, updating frequency and  number of interfaced I/O. Maximum  updating frequency is 50 Hz. • Confi guration guidelines: 1. ESD/PSD: max. 800 I/O,  F&G: max. 700 I/O  both at scan rate: 1 Hz 2. Process/ Automation:  max. 2000 I/O,  design advice: 1280 I/O  both at scan rate: 1 Hz 3. Anti-surge: 3 loops, Scan rate: 50 Hz 4. Dynamic Positioning: Triple  redundant DP system combined  with Position Mooring. (Scan rate  is adapted to signal processing and  varies from 1 to 10 Hz).

KM article number RCU501: 603439 Standards RCU501 complies with the following: • IACS E10 • IEC 60533 • IEC 60945 • IEC 61508 • IEC 62061 Type approval RCU501 is type approved by: • Det Norske Veritas (DNV)  • The American Bureau of Shipping  (ABS)  • TÜV Rheinland • Wurldtech™; Achilles level 1  certifi ed CE marking CE mark compliant, confi rm to: • 2004/108/EC (EMC directive) • 94/9/EC (Atex directive) Ex certifi cation Ex nA II T4 (Zone 2) Environmental  specifi cations Ambient temperatures and humidity: • Temp. Operation: -15˚C to 70˚C • Temp. Storage: -25˚C to 70˚C • Humidity Operation: Up to 98% RH • Humidity Storage: Up to 98% RH Protection Standards: IP 20 Dimensions Height: 355 mm Width: 158 mm Depth: 87 mm Weight: 1.35 kg Cross point screw lock on DIN Rail T35  7.5/15 according to EN 50022 Electrical Input supply voltage: 24 VDC  (+30%, -25%) Nominal current consumption: ≈ 0.8 A Start-up current: Max. 2.7 A Power consumption: Max. 20 W Heat dissipation: Max. 20 W Power connectors:  • Screw terminals (slotted)  • Cable cross section: 2.5 mm² Processor and memory Processor: • Type: Power PCTM host processor  MPC8245 • Clock frequency: 400 MHz Memory: • RAM size and speed: 64 MB @ 133  MHz • PROM: 16 MB application fl ash-fi le Serial line Channels: 32 insulated serial lines,  distributed on 8 RJ45 connectors Physical layer: RS232. RS422 and  RS485 Multidrop via RSER200 Bit rate: Max. 115 kb/s General purpose I/O  channels Digital Output (DO):  • 4 x opto-isolated outputs • 1 x opto-isolated watchdog (for  external interface) Digital Input (DI): 4 x opto-isolated  inputs I/O connectors:  • Cage clamps  • Cable cross section: 1 mm² LAN interface Process network & RedundancyNet:  2 x RJ45 Ethernet IEEE 802.3 type  10BASE-T/100BASE-TX RBUS interface Connector: 2 x RJ45 Bit-rate: 2 Mb/s Signal code: Manchester encoded  (Self-clocked) Copper wire topology: • Insulation: 500 V (Optocoupler) • Physical layer: RS485 Multidrop • Cable attenuation: < 6.5 db/100m @  10 MHz (CAT 5) • Cable length: Max. 200 m between  repeaters. Max. 3 repeaters Fibre optical topology (w/ additional  fi bre media converter): • Fibre cable: 62.5/125 μm. Multimodus • Connector: ST • Cable length: Max. 1000 m (point to  point). 500 m if used in patch-panel  topology Field interface CAN interface:  • 2 x CANopen/DeviceNet @ 5 pole  cage clamp terminals. 2.5 mm² cable • Bit rate: Max. 1 Mb/s. (DeviceNet not  defi ned above 500 kb/s) PROFIBUS interface:  • 2 x opto-isolated 9 Pin female  D-Sub connectors • Bit rate: Max. 12 Mb/s Life cycle prediction Predicted failure rate @ GB 25˚C (60%  confi dent, based on chip suppliers data):  24.2 Years Predicted failure rate @ NS 35˚C  (Environmental de-rating based on Rome  Laboratory toolkit): 6.5 Years


  • GE Fanuc 90-30 PLC Hardware Guide
  • Automation Direct GS2 Drives Tech Guide
  • Comprehensive Technical Guide for OMRON 3G3MV Inverter
  • Danfoss VACON NXI Inverter FI9-FI14 Operation Guide
  • Saia PCD4.U100 System Migration Complete Guide
  • Yaskawa NS300 DeviceNet Module Guide
  • OMRON SYSMAC C-series PLC Programming Guide
  • Kollmorgen ServoStar S Drive Installation and Debugging Guide
  • Omron C200HX/HG/HE PLC Installation and Configuration Guide
  • SIEMENS SINAMICS S120 Driver
  • Emerson ControlWave® Micro Hybrid Controller
  • ABB 800xA for Advant Master Configuration
  • OMRON FQM1 Motion Controller Instruction System
  • Schneider Easergy P5 Communication Architecture and Protocol
  • ABB JOKAB SAFETY Pluto series safety PLC
  • Lenze L-force series HMI EL 100 series human-machine interface
  • Pilz PSEN opII4H series safety light curtain operation instructions
  • Danfoss VACON ® NXP and VACON ® NXC series AC frequency converter
  • EATON Crane Control System Complete Guide
  • ProSoft MVI56-PDPMV1 Module: PROFIBUS DPV1 Master Integration Complete Guide
  • DEIF XDi series FLEXIBLE DISPLAY INDICATORS
  • DEIF AGC 100 series generator set controller
  • DEIF AGC-3 Automatic Generator Set Controller
  • DEIF Multi line 2/version 2-GS Multi functional Generator Protection and Control Unit
  • KONGSBERG AIS BS600 shipborne automatic identification system base station
  • KONGSBERG HMS 300 Helicopter Deck Monitoring System
  • Honeywell HPM Series Particulate Matter Sensors
  • HONEYWELL Expert C300 Controller
  • HONEYWELL HCiX series touch panel operation interface
  • Honeywell T901Px1A Inert Gas Pressure & Temperature Transmitter for Liquid Cargo
  • HONEYWELL Expert Series-C I/O Module
  • HONEYWELL INTELLIKNIGHT®MODEL 5700 Addressable Fire Alarm Control Panel
  • HONEYWELL Expert PKS C300 Controller
  • HONEYWELL Experion Local Control Network   
  • HONEYWELL IRIS P522 Signal Processor Flame Monitoring Equipment
  • HONEYWELL EC7830A, RM7830A, EC7850A, RM7850A 7800 SERIES Relay Modules
  • HONEYWELL Sensepoint XCD Flammable, toxic and oxygen gas detector for industrial applications 
  • HONEYWELL Sensepoint XCD gas detector
  • HONEYWELL Series 61 and Series 62 Modutrol IV™ Motors
  • HONEYWELL M6161, M6181, M6184, M6191, M6194 models Modutrol IV ™ motor
  • Kongsberg C-series Cutting System: Operation, Maintenance, and Tool Technical Guide
  • KONGSBERG DPS i2 is a sensor fusion GNSS solution designed specifically for dynamic positioning (DP)
  • KONGSBERG DPS 114 Durable and Reliable DGNSS (DGPS/DGGLONASS) Sensor
  • KONGSBERG DZ-110/U transmitter safety barrier unit
  • KONGSBERG DZ-120 Zener Safety Barrier Unit
  • KONGSBERG MST 319/324/342 series mini SSBL responder
  • BridgeMaster E 180 and 250 EPA (L) Series of Marine Radars
  • KONGSBERG K-Chief 600 Control Room Panel (CRP) for Ship Automation System
  • KONGSBERG K-MASTER BRIDGE SOLUTIONS
  • Maintenance Manual Kongsberg Steering Gear type SR and SV
  • KONGSBERG RMP420 Remote Multi functional I/O Module
  • KONGSBERG's RMP420 Remote Multifunctional I/O Module
  • Kongsberg WCU Watch Cabin Unit - LED version
  • KONGSBERG K-Nav Navigation Product Series
  • KONGSBERG K-Chief Ship Automation System
  • KONGSBERG RCU 500 Remote Controller
  • Kongsberg Maritime AS Distributed Processing Units Engine Safety Unit (ESU)
  • KUKA KR C5 Robot Controller
  • KUKA KR C4 compact robot controller
  • KUKA KR C2 edition2005 Robot Controller Operation Manual
  • Eaton A200/A210/A250 Specification 5 Motor Controller Operating Manual
  • Eaton MICRO PANEL XV-152 Industrial Tablet Operating Manual
  • Eaton B-Line Series Product Portfolio
  • EATON Time delay undervoltage module
  • Eaton 5P series UPS products
  • Cooper Crouse Hinds EVLS HAZARD-GARD Explosion proof Lamp Installation and Maintenance
  • Eaton EX series UPS products
  • Durant Ambassador Series 5760X-405 Counting Controller Operating Instructions
  • Eaton xEnergy Safety Ci Insulated Distribution Enclosure
  • EATON MICRO PANEL XP-702 Operating Manual
  • EATON SPD series surge protector
  • EATON MVX9000 series sensorless vector frequency converter
  • EATON EasyE4 Nano Compact Programmable Logic Controller
  • EATON Cutler Hammer FP-4000 Medium Voltage Feedline Protection Relay
  • EATON FP-4000 feeder protection relay
  • EATON XT series stabilizing pump control box
  • EATON MP-4000 motor protection relay
  • EATON ELPRO 245U-E series industrial wireless Ethernet products
  • EATON MTL4850 HART multiplexer operating instructions
  • EATON Ambassador series (models 5760X-405, etc.) counting controller
  • EATON Crouse Hinds series of harsh/hazardous environment LED lighting products
  • EATON 9000X AF series (SVX9000/SPX9000) frequency converter
  • EATON S801+series soft starter
  • EATON XV-303/XV-313 series multi touch display
  • EATON XV200 Mini Panel Operation Instructions
  • EATON CG Controller
  • EATON KD, HKD, KDC, CKD, CHKD K-frame molded case circuit breakers
  • EATON Series C Plastic Case Circuit Breaker and Motor Circuit Protector
  • EATON MP-3000 Advanced Motor Protection Relay
  • EATON XV-303/XV-313 series industrial multi touch HMI display
  • EATON Series 8/9 (VISA8/VISA9) vacuum arc extinguishing chamber
  • EATON FP-5000 microprocessor base panel mounted multifunctional protection relay
  • EATON IQ500 modular intelligent multifunctional power meter
  • EXOR eTOP Series 300 Operating Instructions
  • UniOP MD02F-02 and MD02R-04 Compact Low Cost Industrial HMI Equipment
  • UniOP CP02F-02, CP02R-04 Compact Industrial HMI Equipment
  • UniOP CP01R-04, CP05R-04, and CP01F-02 Compact Low Cost HMI Devices
  • UniOP ECT-16 Industrial PLC Workstation Operator Interface System
  • UniOP ePALM10 Handheld Human Computer Interface
  • UniOP ePAD03/ePAD04 Human Computer Interface
  • Union Special XF500 series sewing machine
  • UniOP Universal Operation Panel Installation Guide
  • UniOP eTOP306 Human Computer Interface
  • UniOP Universal Operation Panel Installation Guide
  • Allen-Bradley SLC 500 SYSTEMS SELECTION GUIDE
  • WITTENSTEIN alpha LP+/LPB+low backlash planetary gear reducer
  • ABB AX400 Series Models AX460 and AX466 Single and Dual Input pH/Redox (ORP) Analysts
  • ALSTOM ALSPA series drives
  • ALSTOM ALSPA P1200NT Tripping and Control Relays
  • GE Vernova MVAJ 05/10/20 series is a tripping and control relay
  • GE Vernova MVAW 11/13/21 type intermediate relay
  • ALSTOM ALSPA MV1000 High Performance Low Voltage Inverter
  • GE Vernova MMLG/MMLB Test Blocks and Test Plugs
  • Baker Hughes 1900/65A General Purpose Equipment Monitor
  • DEIF LSU-112DG Load Distribution Unit
  • DEIF PPM 300 Protection and Power Management Controller
  • DEIF Delomitic-3 High Flexibility Multifunctional Generator Set Control and Protection System
  • DEIF DELOMATIC 400 GAS Modular Gas Engine Control and Monitoring System
  • Xiamen Kongjiang Automation Technology Co., Ltd – تأمین‌کننده تخصصی قطعات اتوماسیون صنعتی و سیستم‌های DCS
  • DEIF MULTI-LINE 2 Option X Additional display and operator panel
  • DELL EMC NETWORKING X-SERIES
  • Eaton MP-3000 series motor protection relay
  • Eaton TX series cam switch and PX series load isolation switch
  • Official Operating Instructions for Eaton XControl Series Modular PLCs (XC-104-.../XC-204-.../XC-303-...)
  • Eaton XVS-440-57MPI-1-10 HMI-PLC Function 5.7-inch Infrared Touch Panel
  • Emerson PAC8000 Remote I/O The Control Solution for Process Industries
  • Eaton XV series cylindrical snap on supercapacitor
  • Eaton XV400 10.4"/12.1"/15" MICRO PANEL