Product Description  The safety-related F31 02 controller is a compact system in a metal housing with 20 digital  inputs and 8 digital outputs.  The controller is available in various model variants for SILworX and ELOP II Factory, see  Table 4.  The device is suitable for mounting in Ex-zone 2, see Chapter 4.1.4.

19394.00
¥17474.00
Weight:2.220KG
Quantity:
(Inventory: 33)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

Product Description  The safety-related F31 02 controller is a compact system in a metal housing with 20 digital  inputs and 8 digital outputs.  The controller is available in various model variants for SILworX and ELOP II Factory, see  Table 4.  The device is suitable for mounting in Ex-zone 2, see Chapter 4.1.4.


HIMA-F3102-Safety-Related Controller

3.1.1.1 Reaction in the Event of a Fault  If the device detects a fault on a digital input, the user program processes a low level in  accordance with the de-energized to trip principle.  The device activates the FAULT LED.  In addition to the channel signal value, the user program must also consider the corresponding  error code.  The error code allows the user to configure additional fault reactions in the user program.  3.1.1.2 Line Control  Line control is used to detect short-circuits or open-circuits and can be configured for the F31  system, e.g., on EMERGENCY STOP inputs complying with Cat. 4 and PL e in accordance with  EN ISO 13849-1.  To this end, connect the digital outputs DO 1 through DO 8 of the system to the digital inputs DI  of the same system as follows:   EMERGENCY STOP 1   EMERGENCY STOP 2   EMERGENCY STOP switches in  accordance with EN 60947-5-1 and  EN 60947-5-5  Figure 2: Line Control  The controller pulses the digital outputs to detect the line short-circuits and open-circuits on the  lines connected to the digital inputs. To do so, configure the Value [BOOL] -> system variable in  SILworX or the DO[01].Value system signal in ELOP II Factory. The variables for the pulsed  outputs must begin with channel 1 and reside in direct sequence, one after the other.  If the following faults occur, the FAULT LED located on the front plate of the controller blinks,  the inputs are set to low level and an (evaluable) error code is created:   Cross-circuit between two parallel wires.   Invalid connections of two lines (e.g., DO 2 to DI 3),   Earth fault on one wire (with earthed ground only).   Open-circuit or open contacts, i.e., including when one of the two EMERGENCY STOP  switches mentioned above has been engaged, the FAULT LED blinks and the error code is  created.

Safety-Related Digital Outputs  The controller is equipped with 8 digital outputs. The state (HIGH, LOW) of each output is  signaled by an individual LED (HIGH, LOW).  At the maximum ambient temperature, the outputs 1...3 and 5...7 can be loaded with 0.5 A  each; and outputs 4 and 8 can be loaded with 1 A or with 2 A at an ambient temperature of up  to 50 °C.  If an overload occurs, one or all digital outputs are switched off. If the overload is removed, the  outputs are switched on again automatically, see Table 17.  The external wire of an output is not monitored, however, a detected short-circuit is signaled.  Figure 3: Connection of Actuators to Outputs  The redundant connection of two outputs must be decoupled with diodes.  CAUTION For connecting a load to a 1-pole switching output, use the corresponding L- ground of  the respective channel group (2-pole connection) to ensure that the internal protective  circuit can function.   Inductive loads may be connected with no free-wheeling diode on the actuator. However, HIMA  strongly recommends connecting a protective diode directly to the actuator.  3.1.2.1 Reaction in the Event of a Fault  If the device detects a faulty signal on a digital output, the affected module output is set to the  safe (de-energized) state using the safety switches.  If a device fault occurs, all digital outputs are switched off.  In both cases, the devices activates the FAULT LED.  The error code allows the user to configure additional fault reactions in the user program.

LED Indicators  The light-emitting diodes (LEDs) indicate the operating state of the controller. The LEDs are  classified as follows:   Operating voltage LED   System LEDs   Communication LEDs   I/O LEDs  Function and meaning of the system LEDs and communication LEDs depend on the CPU  operating system (and thus on the COM operating system).  When the supply voltage is switched on, a LED test is performed and all LEDs are briefly lit.  Definition of Blinking Frequencies The following table defines the blinking frequencies of the LEDs:  Name Blinking frequencies  Blinking Non-specified blinking, with CPU OS up to V7.x  Blinking1 Long (approx. 600 ms) on, long (approx. 600 ms) off, with CPU OS V8 and  higher  Blinking-x Ethernet communication: Blinking synchronously with data transfer,  with CPU OS V8 and higher  Table 5: Blinking Frequencies of LEDs  3.4.1.1 Operating Voltage LED  The operating voltage LED does not depend on the CPU operating system in use.  LED Color Status Description  On 24 VDC operating voltage present 24 VDC Green  Off No operating voltage  Table 6: Operating Voltage LED


  • ROSS Pneumatic Control System Full Series
  • BD SENSORS DMP 333 Industrial Pressure Transmitter
  • OE Max Controls NX70 series programmable controller
  • SAIA PCD4.W500 (Analog Input Module) and PCD4.W600 (Analog Output Module)
  • Saia Burgess PCD4. U100 kit PCD4 controller upgrade tool
  • SAIA PCD1 series programmable controller
  • SAIA Burgess PCD2.H110 Universal Counting and Measurement Module
  • SAMSON 430 Series 3434 Pneumatic Controller Module
  • SanDisk iNAND ® Series of Embedded Flash Drives (EFDs) and OEM microSD ™ card
  • Optimus® Product Family of SAS SSDs
  • SANMOTION PB series AC power input stepper system
  • ADCA LINEAR ELECTRIC ACTUATORS AVF234S and AVM234S
  • SBS Technologies VIPC616 Four Slot 6U VMEbus IndustryPack Carrier
  • SBS Technologies VIPC616 Four Slot 6U VMEbus IndustryPack Carrier
  • Greenspring P2-Video General Purpose CRT and LCD Video Graphics Controller
  • ABB UniPack-S Steel Compact Secondary Substation
  • Schaffner Ecosine ® Economy Line FS 42842 Compact Passive Harmonic Filter
  • Schenck Process INTECONT® Tersus for Measuring Systems
  • Entrelec compact contactors, small contactors, control relays, and supporting system components
  • Smiths connectors MHD/MDD/MDP series high-density PCB connectors
  • SEW EURODRIVE DFP21B PROFIBUS DP-V1 Fieldbus Interface Description
  • SEW-EURODRIVE MOVIDRIVE ® MDX60B/61B series frequency converter system
  • SEW Eurodrive R series parallel axis gear motor
  • SEW EURODRIVE DFS/DFY series synchronous motors
  • SEW EURODRIVE MOVITRAC 31C series frequency converter
  • SEW EURODRIVE MOVIDYN ® Description of Communication Interface for Servo Controller
  • SEW EURODRIVE's MOVIDRIVE ® Series frequency converter UL certification related technical data sheet
  • SEW MOVIDRIVE ® MD-60A frequency converter bus positioning function
  • SEW MOVIDYN ® Series servo controller
  • SEW EURODRIVE MOVIDRIVE ® MD-60A series frequency converter
  • BTicino Megatiker M5 electronic circuit breakers
  • BTicino Megatiker M4 Thermal magnetic and MS4 trip-free switches
  • BTicino Megatiker M3 160 Thermal Magnetic Circuit Breaker and MS3 160 Isolation Switch
  • Bticino MEGATIKER series industrial distribution protection equipment
  • Elmex brand's industrial control and instrumentation products
  • Danfoss VLT ® Series 3000 series adjustable frequency drive
  • Rockwell Automation SLC 500 Series Programmable Logic Controller
  • YOKOGAWA CENTUM CS 3000 Integrated Production Control System
  • OMRON SYSMAC CS Series CS1G/H-CPU  H Programmable Controller
  • MEGGITT TQ 422/TQ 432/EA 402/IQS 450 Proximity Measurement System
  • MEGGITT VM600 machinery protection system (MPS)
  • IbaDeskline SAS Industrial Computer
  • IbaDAQ-C Compact Device for Independent Data Acquisition
  • IbaFOB io ExpressCard fiber optic interface card
  • IbaPADU-S-IT-16 modular central unit
  • YASKAWA ∑ - II Series SGMBH/SGDH AC Servo System
  • ibaBM-CAN CAN / CANopen Bus Sniffer
  • IbaLink-SM-128V-i-2O VMEbus interface board
  • GE Fanuc 90-30 PLC Hardware Guide
  • Automation Direct GS2 Drives Tech Guide
  • Comprehensive Technical Guide for OMRON 3G3MV Inverter
  • Danfoss VACON NXI Inverter FI9-FI14 Operation Guide
  • Saia PCD4.U100 System Migration Complete Guide
  • Yaskawa NS300 DeviceNet Module Guide
  • OMRON SYSMAC C-series PLC Programming Guide
  • Kollmorgen ServoStar S Drive Installation and Debugging Guide
  • Omron C200HX/HG/HE PLC Installation and Configuration Guide
  • SIEMENS SINAMICS S120 Driver
  • Emerson ControlWave® Micro Hybrid Controller
  • ABB 800xA for Advant Master Configuration
  • OMRON FQM1 Motion Controller Instruction System
  • Schneider Easergy P5 Communication Architecture and Protocol
  • ABB JOKAB SAFETY Pluto series safety PLC
  • Lenze L-force series HMI EL 100 series human-machine interface
  • Pilz PSEN opII4H series safety light curtain operation instructions
  • Danfoss VACON ® NXP and VACON ® NXC series AC frequency converter
  • EATON Crane Control System Complete Guide
  • ProSoft MVI56-PDPMV1 Module: PROFIBUS DPV1 Master Integration Complete Guide
  • DEIF XDi series FLEXIBLE DISPLAY INDICATORS
  • DEIF AGC 100 series generator set controller
  • DEIF AGC-3 Automatic Generator Set Controller
  • DEIF Multi line 2/version 2-GS Multi functional Generator Protection and Control Unit
  • KONGSBERG AIS BS600 shipborne automatic identification system base station
  • KONGSBERG HMS 300 Helicopter Deck Monitoring System
  • Honeywell HPM Series Particulate Matter Sensors
  • HONEYWELL Expert C300 Controller
  • HONEYWELL HCiX series touch panel operation interface
  • Honeywell T901Px1A Inert Gas Pressure & Temperature Transmitter for Liquid Cargo
  • HONEYWELL Expert Series-C I/O Module
  • HONEYWELL INTELLIKNIGHT®MODEL 5700 Addressable Fire Alarm Control Panel
  • HONEYWELL Expert PKS C300 Controller
  • HONEYWELL Experion Local Control Network   
  • HONEYWELL IRIS P522 Signal Processor Flame Monitoring Equipment
  • HONEYWELL EC7830A, RM7830A, EC7850A, RM7850A 7800 SERIES Relay Modules
  • HONEYWELL Sensepoint XCD Flammable, toxic and oxygen gas detector for industrial applications 
  • HONEYWELL Sensepoint XCD gas detector
  • HONEYWELL Series 61 and Series 62 Modutrol IV™ Motors
  • HONEYWELL M6161, M6181, M6184, M6191, M6194 models Modutrol IV ™ motor
  • Kongsberg C-series Cutting System: Operation, Maintenance, and Tool Technical Guide
  • KONGSBERG DPS i2 is a sensor fusion GNSS solution designed specifically for dynamic positioning (DP)
  • KONGSBERG DPS 114 Durable and Reliable DGNSS (DGPS/DGGLONASS) Sensor
  • KONGSBERG DZ-110/U transmitter safety barrier unit
  • KONGSBERG DZ-120 Zener Safety Barrier Unit
  • KONGSBERG MST 319/324/342 series mini SSBL responder
  • BridgeMaster E 180 and 250 EPA (L) Series of Marine Radars
  • KONGSBERG K-Chief 600 Control Room Panel (CRP) for Ship Automation System
  • KONGSBERG K-MASTER BRIDGE SOLUTIONS
  • Maintenance Manual Kongsberg Steering Gear type SR and SV
  • KONGSBERG RMP420 Remote Multi functional I/O Module
  • KONGSBERG's RMP420 Remote Multifunctional I/O Module
  • Kongsberg WCU Watch Cabin Unit - LED version
  • KONGSBERG K-Nav Navigation Product Series
  • KONGSBERG K-Chief Ship Automation System
  • KONGSBERG RCU 500 Remote Controller
  • Kongsberg Maritime AS Distributed Processing Units Engine Safety Unit (ESU)
  • KUKA KR C5 Robot Controller
  • KUKA KR C4 compact robot controller
  • KUKA KR C2 edition2005 Robot Controller Operation Manual
  • Eaton A200/A210/A250 Specification 5 Motor Controller Operating Manual
  • Eaton MICRO PANEL XV-152 Industrial Tablet Operating Manual
  • Eaton B-Line Series Product Portfolio
  • EATON Time delay undervoltage module
  • Eaton 5P series UPS products
  • Cooper Crouse Hinds EVLS HAZARD-GARD Explosion proof Lamp Installation and Maintenance
  • Eaton EX series UPS products
  • Durant Ambassador Series 5760X-405 Counting Controller Operating Instructions
  • Eaton xEnergy Safety Ci Insulated Distribution Enclosure
  • EATON MICRO PANEL XP-702 Operating Manual
  • EATON SPD series surge protector
  • EATON MVX9000 series sensorless vector frequency converter
  • EATON EasyE4 Nano Compact Programmable Logic Controller
  • EATON Cutler Hammer FP-4000 Medium Voltage Feedline Protection Relay
  • EATON FP-4000 feeder protection relay
  • EATON XT series stabilizing pump control box
  • EATON MP-4000 motor protection relay
  • EATON ELPRO 245U-E series industrial wireless Ethernet products
  • EATON MTL4850 HART multiplexer operating instructions
  • EATON Ambassador series (models 5760X-405, etc.) counting controller