Emerson M-series Virtual I/O Module2
❤ Add to collection

Emerson M-series Virtual I/O Module2

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

Introduction The DeltaV M-series Virtual I/O Module 2 (VIM2)  provides nonintrusive simulation of the DeltaV Mseries I/O Cards and digital bus field devices for  process simulation when used with MYNAH  Technologies’ MiMiC Simulation Software. DeltaV  Control strategies and system configurations can be  fully tested with this powerful simulation interface.

11000.00
¥10000.00
Weight:3.220KG
Quantity:
(Inventory: 12)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

Introduction The DeltaV M-series Virtual I/O Module 2 (VIM2)  provides nonintrusive simulation of the DeltaV Mseries I/O Cards and digital bus field devices for  process simulation when used with MYNAH  Technologies’ MiMiC Simulation Software. DeltaV  Control strategies and system configurations can be  fully tested with this powerful simulation interface.


Emerson M-series Virtual I/O Module2

The VIM2 also provides an interface to Ethernet I/O

networks and devices that use the Modbus TCP/IP

or Ethernet/IP protocol drivers. DeltaV M-series

controllers can read and write signals from plant

floor devices connected to Ethernet I/O networks

such as PLC’s, Motor Control Centers, and Weigh

Scales.

Benefits

Non-Intrusive DeltaV I/O simulation. Use the VIM2

in conjunction with the MYNAH Technologies’ MiMiC

Simulation Software to simulate your DeltaV M-Series

I/O and digital bus field devices.

 Supports DeltaV I/O modules. Provides completely

non-intrusive simulation of all DeltaV M-series I/O

Modules. Supports autosensing of I/O and accurate

testing of controller loading. DeltaV configuration can

be fully tested without modifying the control

strategies.

 Digital bus support. Provides simulation of all

DeltaV Digital Busses and Foundation Fieldbus

function blocks. Supports Foundation Fieldbus control

in the field configuration testing.

 Powerful simulation solution. Provides full

simulation of up to 64 DeltaV I/O modules per

controller. Simulation execution is fast and efficient;

the DeltaV controller thinks it’s talking with real IO.

Powerful integration solution. Use the VIM2 in

conjunction with the MYNAH Ethernet I/O drivers to

integrate your DeltaV system with your Ethernet I/O device

networks.

 Large device capacity. Each VIM emulates four

DeltaV Serial Cards and support up to 128 Serial

Card Datasets of information from 32 network devices

in simplex installations and 16 devices in redundant

installations. Communication over the Ethernet I/O

device network is fast and efficient.

 Flexible networking. User configurable IP

addressing allows the VIM2 to be used in almost any

plant environment regardless of networking scheme.

The VIM2 and the Ethernet I/O devices must be on

the same IP subnet to communicate.

 1:1 Redundancy. Redundancy can be added to any

Ethernet I/O system by adding a second VIM2 and

configuring the two cards as a redundant pair. The

VIM2 appears as four redundant DeltaV Serial Card

pairs. Automatic switchover of primary to standby

cards is handled like the DeltaV Serial Card. The

operator is given clear notification of a switchover at

the operator display. Manual switchover can be

controlled in DeltaV Diagnosti

Automatic updates. Simulation I/O driver updates for

the VIM2 are included with the MiMiC software

releases. Updates are quick and easy over the

simulation network.

 Seamless Ethernet I/O integration. When used with

the MYNAH Ethernet I/O drivers, the VIM2 is seen by

the DeltaV M-series controller as four DeltaV Serial

Cards. Commissioned VIM2s are auto-sensed by the

DeltaV controller as DeltaV Serial Cards.

 Configured in DeltaV Explorer. Serial dataset

configuration used for Ethernet I/O integration is done

in the DeltaV Explorer in the same manner as a

DeltaV Serial Card. Ethernet I/O signals can be used

in DeltaV Control Modules, displayed on DeltaV

Operate graphics and stored in the DeltaV

Continuous Historian.

 Intuitive setup. The VIMNet Explorer application

provides plug-n-play capability making setup of the

VIM2 easy and intuitive. Graphical, drag-n-drop,

functionality makes setting up multiple VIM2s almost

effortless. VIMNet Explorer is integrated with DeltaV

Explorer to make setup of the VIM2 easy and intuitive.

Modular, flexible packaging. The VIM2 mounts in the

same manner as the DeltaV controller. It mounts in the

controller slot of a DeltaV 2-wide horizontal or 4-wide

vertical carrier and uses a standard DeltaV Power Supply.

The advanced design of the VIM2 will provide years of

uninterrupted use.

IO Simulation When used with MYNAH’s MiMiC

Simulation Software, the VIM2 supports I/O simulation all

DeltaV M-series I/O cards including classic IO, Foundation

Fieldbus, ProfibusDP, DeviceNet, ASi-bus and Serial.

MiMiC Simulation Software provide dynamic simulation for

DeltaV system software acceptance testing and operator

training. The MiMiC software works by simulating the

DeltaV I/O. It also simulates field devices using

Foundation Fieldbus, ProfibusDP, DeviceNet and AS-i

buses. In order for MiMiC to do this, the real I/O cards are

disconnected from the control system. The MiMiC driver

writes to the I/O subsystem of the DeltaV controller.

Process models in MiMiC simulate realistic process

reactions to control system output signals.

Each process controller being simulated uses one MiMiC

Dataset. A MiMiC server can have up to 32 datasets or

ports. Each dataset can support up to 4000 MiMiC

simulation tags.

The I/O simulation driver is provided with the VIM2

hardware, pre-loaded in the VIM2. The MiMiC Simulation

Software must be purchased separately from MYNAH

Technologies. Technical support for the MiMiC Simulation

Software and I/O simulation driver is provided by MYNAH

Technologies.

Ethernet I/O Integration When used with the MYNAH

Ethernet I/O drivers, the VIM2 can communicate with

high-speed Ethernet networks over Modbus TCP or

Ethernet/IP. When the VIM2 is configured with the

appropriate Ethernet I/O driver, the DeltaV Controller autosenses a commissioned VIM2 as four DeltaV Serial Cards.

 In simplex installations these cards will be sensed in

slots 57-60 or 61-64.

 In redundant installations the redundant pairs will be

sensed in slots 57 to 64.

Configuration of the I/O signals from the commissioned

VIM2 is done in the DeltaV Explorer in the same manner

as a DeltaV Serial Card.

VIMNet Explorer. The VIMNet Explorer utility allows the

user to commission the VIM2. setup primary and

redundant VIM2s, and the Ethernet I/O network. The useris able

  • Zygo 3D Optical Profiler
  • Zygo Mark II 4-inch interferometer system
  • Zygo NewView 9000 3D Optical Contour Analyzer Core Features
  • Zygo NewView 9000 3D Optical Profilometer Technology
  • Zygo Profilometer Standard Operating Procedure
  • Zygo’s Guide to Typical Interferometer Setups
  • ZYGO Laser Interferometer Accessory Guide OMP-0463AM
  • ZYGO MetroPro 9.0 Reference Guide (OMP-0347M)
  • Zygo Device Standard Operating Procedure (SOP)
  • Zygo Verify Laser Interferometer
  • Zygo MicroLUPI interferometer
  • ZYGO ZMI-1000 Displacement Measuring Interferometer System
  • Zygo's ZMI 2000 displacement measurement interferometer system
  • ABB IGCT Technology: A Revolutionary Breakthrough in High Voltage Inverters
  • Siemens 6AG1204-2BB10-4AA3 Ethernet Switch
  • Siemens 6ES7193-4JA00-0AA0 Terminal Module
  • Siemens ET200SP 6ES7193-6PA00-0AA0 server module
  • Siemens 6ES7231-0HC22-0XA0 Analog Input Expansion Module
  • Siemens 6ES7350-2AH01-0AE0 Counter Module
  • Siemens 6ES7421-7DH00-0AB0 Digital Input Module
  • Siemens 6AV2124-2DC01-0AX0 Comfort Panel
  • Siemens 6ES7193-4CA40-0AA0 ET 200S Electronic Module
  • STOBER POSIDRIVE ® MDS 5000 installation method
  • Siemens 7XV5653-0BA00 dual channel binary signal transmitter
  • Bently Nevada 3500/65 145988-02 Channel Temperature Monitor
  • Thinklogical Velocity KVM-34 series KVM fiber extender
  • Watlow MLS300 Series Controller
  • ​DHR NLS3000 NLC System (Navigation Control System)
  • Watlow Anafaze CLS200 Series Controller
  • CyberPower UT650EG / UT850EG User’s Manual
  • Thermal Solutions EVS series gas regulated boilers
  • Bosch Rexroth HM20 Hydraulic Pressure Sensor
  • ABB SPAU 341 C Voltage Regulator
  • Rockwell Automation 1585 Ethernet Media
  • Rockwell Automation SmartGuard 600 Controller
  • Rockwell Automation 1756 ControlLogix Communication Module
  • Rockwell Automation Stratix series Ethernet devices
  • A-B Ultra3000 and Ultra5000 with DeviceNet
  • ABB INNIS21 Network Interface Slave module
  • DEIF RMV-111D undervoltage and overvoltage relay
  • SAUTER AVM 234S valve actuator (with positioner)
  • REXRTOH INDRAMAT TVD 1.3 power module
  • Honeywell Expert Series-C I/O Module
  • ​GE PACSystems RX7i power module (IC698PSA100/350 series)
  • Yokogawa AFV40S/AFV40D Field Control Unit (FCU)
  • Schneider 31H2S207 FBM207/b/c Voltage Monitor/Contact Sense Input Modules
  • Emerson S Series Traditional I/O Modules
  • MKS Type T3B Butterfly Valve (with DeviceNet Interface)
  • Triconex 3624 Digital Output Module
  • ABB 3BSE031151R1 PM865K01 Processor Unit HI
  • GE V7768 VME Single Board Computer
  • HIMatrix F30 01 Safety-Related Controller
  • Welker Bearing Linear Guides and Wedge Components
  • GE Multilin MIF series digital feeder relay
  • ABB MNS iS MConnect interface
  • Emerson PR6426 32mm Eddy Current Sensor
  • Schneider ELAU PacDrive C400/C400 A8 Controller
  • Yokogawa Motor YS1700 Programmable Indicator Controller
  • Honeywell Searchline Excel Infrared Open Circuit Gas Detector
  • Rockwell Automation ICS AADvance Controller
  • ABB Relion ® 615 series RED615 line differential protection and control device
  • DEIF PPU-3 Parallel and Protection Unit
  • Foxboro PBCO-D8-009 Terminal Board (TB)
  • ASEM HT2150/QT2150 Fanless Panel Control Computer (IPC)
  • ABB FOUNDATION ™ Fieldbus Link Device LD 810HSE Ex V1.0
  • ABB Panel 800 Version 6 PP885 Hardware and Installation
  • Konica Minolta CM-3700A-U Plus spectrophotometer
  • Schneider FBM233 Field Device System Integrator Module
  • MTL 8502-BI-DP Bus Interface Module (BIM)
  • ABB DO880 Ability ™ System 800xA ® hardware selector
  • GE VMIVME-2540 24 channel intelligent counter/controller
  • GE VMIVME-3115-010 32-Channel 12-bit Analog Output Board
  • GE Fanuc Automation VMIVME-4140 32-Channel 12-bit Analog Output Board
  • BENTLY 1900/65A General Purpose Equipment Monitor
  • REXROTH Digital axis control HNC100
  • GE Grid Solutions 369 Series
  • ZYGO ZMI 7702 laser head
  • ZYGO ZMI 501A shell
  • ABB PFEA111-65 Tension Electronic Equipment
  • Allen Bradley 1753 Series GuardPLC 1800 Controller
  • Allen Bradley 1753 Series GuardPLC 1800 Controller
  • Allen Bradley 1747-DCM Direct Communication Module
  • Allen Bradley 1746-NI8 SLC 500 Analog Input Module
  • Allen Bradley 1734 series POINT I/O common terminal module and voltage terminal module
  • Allen Bradley 150 Series SMC Dialog Plus Controller
  • Allen Bradley 1494V series
  • AB Allen Bradley 1492 series terminal block
  • Allen Bradley 1485 Series DeviceNet Media System
  • Allen Bradley 1391-DES series digital AC servo drive
  • Allen Bradley 1336 PLUS II Adjustable Frequency Driver
  • Allen Bradley 1336 IMPACT AC Inverter
  • Allen Bradley 1326AB high-performance AC servo motor
  • Allen Bradley DeviceNet Communication Module (1203-GK5/1336-GM5)
  • Allen Bradley 1203-CN1 ControlNet Communication Module
  • Rockwell Automation PanelView Standard Series Terminal (Model 2711)
  • Siemens SIMATIC S7-300 6ES7322-1BH01-0AA0 Digital Output Module
  • Siemens SIMATIC S7-300 Digital Input Module (6ES7321-1BH02-0AA0)
  • Rockwell Automation 836T Series Differential Pressure Controller
  • Schneider Modicon Quantum 140DRA84000 Discrete Output Module
  • Schneider Modicon Quantum 140CPS11420 power module
  • Schneider Modicon Quantum 140ACO02000 Analog Output Module
  • Schneider Modicon Quantum 140CPU65260 Unity Processor
  • SIEMENS 6GK1105-2AA10 SIMATIC NET series optical switching module (OSM ITP62)
  • Modicon Quantum 140XBP01000 racks backplanes
  • ABB NTST01 Time Sync Link TU Time Sync Link Terminal Unit
  • Siemens 6ES7954-8LC02-0AA0 SIMATIC Memory Card
  • Siemens 6ES7511-1AK02-0AB0 SIMATIC S7-1500 CPU 1511-1 PN Central Processing Unit
  • Allen Bradley 1769-L32E (CompactLogix L32E) Programmable Automation Controller
  • Allen-Bradley 2711P-RDT7C PanelView ™ Plus 6 700 Industrial Human Computer Interface
  • Siemens 6AV6642-0DA01-1AX1 SIMATIC OP177B Industrial Human Machine Interface (HMI)
  • Emerson PACSystems RX3i I/O Module
  • Moxa EDS-508A series network managed Ethernet switch
  • Moxa EDS-408A series industrial Ethernet switch
  • ABB TK821V020 (3BSC95020R1) battery cable
  • Sonnax 6R80L-6R100-ZIP Transmission Valve Body Repair Kit
  • Moxa EDS-308 series industrial Ethernet switch
  • ABB Symphony Plus S+Control BRC410 Controller
  • GE Qualitrol IC670ALG230 Analog Input Module
  • ABB DCS series thyristor power converter
  • Schneider Electric Foxboro ™ DCS FBM201/b/c/d analog input module
  • Eaton XV-440-10TVB-1-20 Human Machine Interface (HMI)
  • Bentley Baker Hughes 2300 Series Vibration Monitors
  • Allen-Bradley IMC ™ S Class Compact Motion Controllers (IMC-S/23x model)
  • Siemens 6AV7875-0BC20-1AC0 SIMATIC HMI
  • Siemens 6AV6645-0CB01-0AX0 Mobile Panel
  • Siemens 6DD1607-0AA2 module
  • GE IC693MDL655 Discrete Input Module
  • ABB AI820 3BSE008544R1 Analog Input Module