K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
Emerson M-series Virtual I/O Module2
❤ Add to collection

Emerson M-series Virtual I/O Module2

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

Introduction The DeltaV M-series Virtual I/O Module 2 (VIM2)  provides nonintrusive simulation of the DeltaV Mseries I/O Cards and digital bus field devices for  process simulation when used with MYNAH  Technologies’ MiMiC Simulation Software. DeltaV  Control strategies and system configurations can be  fully tested with this powerful simulation interface.

11000.00
¥10000.00
Weight:3.220KG
Quantity:
(Inventory: 12)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

Introduction The DeltaV M-series Virtual I/O Module 2 (VIM2)  provides nonintrusive simulation of the DeltaV Mseries I/O Cards and digital bus field devices for  process simulation when used with MYNAH  Technologies’ MiMiC Simulation Software. DeltaV  Control strategies and system configurations can be  fully tested with this powerful simulation interface.


Emerson M-series Virtual I/O Module2

The VIM2 also provides an interface to Ethernet I/O

networks and devices that use the Modbus TCP/IP

or Ethernet/IP protocol drivers. DeltaV M-series

controllers can read and write signals from plant

floor devices connected to Ethernet I/O networks

such as PLC’s, Motor Control Centers, and Weigh

Scales.

Benefits

Non-Intrusive DeltaV I/O simulation. Use the VIM2

in conjunction with the MYNAH Technologies’ MiMiC

Simulation Software to simulate your DeltaV M-Series

I/O and digital bus field devices.

 Supports DeltaV I/O modules. Provides completely

non-intrusive simulation of all DeltaV M-series I/O

Modules. Supports autosensing of I/O and accurate

testing of controller loading. DeltaV configuration can

be fully tested without modifying the control

strategies.

 Digital bus support. Provides simulation of all

DeltaV Digital Busses and Foundation Fieldbus

function blocks. Supports Foundation Fieldbus control

in the field configuration testing.

 Powerful simulation solution. Provides full

simulation of up to 64 DeltaV I/O modules per

controller. Simulation execution is fast and efficient;

the DeltaV controller thinks it’s talking with real IO.

Powerful integration solution. Use the VIM2 in

conjunction with the MYNAH Ethernet I/O drivers to

integrate your DeltaV system with your Ethernet I/O device

networks.

 Large device capacity. Each VIM emulates four

DeltaV Serial Cards and support up to 128 Serial

Card Datasets of information from 32 network devices

in simplex installations and 16 devices in redundant

installations. Communication over the Ethernet I/O

device network is fast and efficient.

 Flexible networking. User configurable IP

addressing allows the VIM2 to be used in almost any

plant environment regardless of networking scheme.

The VIM2 and the Ethernet I/O devices must be on

the same IP subnet to communicate.

 1:1 Redundancy. Redundancy can be added to any

Ethernet I/O system by adding a second VIM2 and

configuring the two cards as a redundant pair. The

VIM2 appears as four redundant DeltaV Serial Card

pairs. Automatic switchover of primary to standby

cards is handled like the DeltaV Serial Card. The

operator is given clear notification of a switchover at

the operator display. Manual switchover can be

controlled in DeltaV Diagnosti

Automatic updates. Simulation I/O driver updates for

the VIM2 are included with the MiMiC software

releases. Updates are quick and easy over the

simulation network.

 Seamless Ethernet I/O integration. When used with

the MYNAH Ethernet I/O drivers, the VIM2 is seen by

the DeltaV M-series controller as four DeltaV Serial

Cards. Commissioned VIM2s are auto-sensed by the

DeltaV controller as DeltaV Serial Cards.

 Configured in DeltaV Explorer. Serial dataset

configuration used for Ethernet I/O integration is done

in the DeltaV Explorer in the same manner as a

DeltaV Serial Card. Ethernet I/O signals can be used

in DeltaV Control Modules, displayed on DeltaV

Operate graphics and stored in the DeltaV

Continuous Historian.

 Intuitive setup. The VIMNet Explorer application

provides plug-n-play capability making setup of the

VIM2 easy and intuitive. Graphical, drag-n-drop,

functionality makes setting up multiple VIM2s almost

effortless. VIMNet Explorer is integrated with DeltaV

Explorer to make setup of the VIM2 easy and intuitive.

Modular, flexible packaging. The VIM2 mounts in the

same manner as the DeltaV controller. It mounts in the

controller slot of a DeltaV 2-wide horizontal or 4-wide

vertical carrier and uses a standard DeltaV Power Supply.

The advanced design of the VIM2 will provide years of

uninterrupted use.

IO Simulation When used with MYNAH’s MiMiC

Simulation Software, the VIM2 supports I/O simulation all

DeltaV M-series I/O cards including classic IO, Foundation

Fieldbus, ProfibusDP, DeviceNet, ASi-bus and Serial.

MiMiC Simulation Software provide dynamic simulation for

DeltaV system software acceptance testing and operator

training. The MiMiC software works by simulating the

DeltaV I/O. It also simulates field devices using

Foundation Fieldbus, ProfibusDP, DeviceNet and AS-i

buses. In order for MiMiC to do this, the real I/O cards are

disconnected from the control system. The MiMiC driver

writes to the I/O subsystem of the DeltaV controller.

Process models in MiMiC simulate realistic process

reactions to control system output signals.

Each process controller being simulated uses one MiMiC

Dataset. A MiMiC server can have up to 32 datasets or

ports. Each dataset can support up to 4000 MiMiC

simulation tags.

The I/O simulation driver is provided with the VIM2

hardware, pre-loaded in the VIM2. The MiMiC Simulation

Software must be purchased separately from MYNAH

Technologies. Technical support for the MiMiC Simulation

Software and I/O simulation driver is provided by MYNAH

Technologies.

Ethernet I/O Integration When used with the MYNAH

Ethernet I/O drivers, the VIM2 can communicate with

high-speed Ethernet networks over Modbus TCP or

Ethernet/IP. When the VIM2 is configured with the

appropriate Ethernet I/O driver, the DeltaV Controller autosenses a commissioned VIM2 as four DeltaV Serial Cards.

 In simplex installations these cards will be sensed in

slots 57-60 or 61-64.

 In redundant installations the redundant pairs will be

sensed in slots 57 to 64.

Configuration of the I/O signals from the commissioned

VIM2 is done in the DeltaV Explorer in the same manner

as a DeltaV Serial Card.

VIMNet Explorer. The VIMNet Explorer utility allows the

user to commission the VIM2. setup primary and

redundant VIM2s, and the Ethernet I/O network. The useris able

  • Allen Bradley 1753 Series GuardPLC 1800 Controller
  • Allen Bradley 1753 Series GuardPLC 1800 Controller
  • Allen Bradley 1747-DCM Direct Communication Module
  • Allen Bradley 1746-NI8 SLC 500 Analog Input Module
  • Allen Bradley 1734 series POINT I/O common terminal module and voltage terminal module
  • Allen Bradley 150 Series SMC Dialog Plus Controller
  • Allen Bradley 1494V series
  • AB Allen Bradley 1492 series terminal block
  • Allen Bradley 1485 Series DeviceNet Media System
  • Allen Bradley 1391-DES series digital AC servo drive
  • Allen Bradley 1336 PLUS II Adjustable Frequency Driver
  • Allen Bradley 1336 IMPACT AC Inverter
  • Allen Bradley 1326AB high-performance AC servo motor
  • Allen Bradley DeviceNet Communication Module (1203-GK5/1336-GM5)
  • Allen Bradley 1203-CN1 ControlNet Communication Module
  • Rockwell Automation PanelView Standard Series Terminal (Model 2711)
  • Siemens SIMATIC S7-300 6ES7322-1BH01-0AA0 Digital Output Module
  • Siemens SIMATIC S7-300 Digital Input Module (6ES7321-1BH02-0AA0)
  • Rockwell Automation 836T Series Differential Pressure Controller
  • Schneider Modicon Quantum 140DRA84000 Discrete Output Module
  • Schneider Modicon Quantum 140CPS11420 power module
  • Schneider Modicon Quantum 140ACO02000 Analog Output Module
  • Schneider Modicon Quantum 140CPU65260 Unity Processor
  • SIEMENS 6GK1105-2AA10 SIMATIC NET series optical switching module (OSM ITP62)
  • Modicon Quantum 140XBP01000 racks backplanes
  • ABB NTST01 Time Sync Link TU Time Sync Link Terminal Unit
  • Siemens 6ES7954-8LC02-0AA0 SIMATIC Memory Card
  • Siemens 6ES7511-1AK02-0AB0 SIMATIC S7-1500 CPU 1511-1 PN Central Processing Unit
  • Allen Bradley 1769-L32E (CompactLogix L32E) Programmable Automation Controller
  • Allen-Bradley 2711P-RDT7C PanelView ™ Plus 6 700 Industrial Human Computer Interface
  • Siemens 6AV6642-0DA01-1AX1 SIMATIC OP177B Industrial Human Machine Interface (HMI)
  • Emerson PACSystems RX3i I/O Module
  • Moxa EDS-508A series network managed Ethernet switch
  • Moxa EDS-408A series industrial Ethernet switch
  • ABB TK821V020 (3BSC95020R1) battery cable
  • Sonnax 6R80L-6R100-ZIP Transmission Valve Body Repair Kit
  • Moxa EDS-308 series industrial Ethernet switch
  • ABB Symphony Plus S+Control BRC410 Controller
  • GE Qualitrol IC670ALG230 Analog Input Module
  • ABB DCS series thyristor power converter
  • Schneider Electric Foxboro ™ DCS FBM201/b/c/d analog input module
  • Eaton XV-440-10TVB-1-20 Human Machine Interface (HMI)
  • Bentley Baker Hughes 2300 Series Vibration Monitors
  • Allen-Bradley IMC ™ S Class Compact Motion Controllers (IMC-S/23x model)
  • Siemens 6AV7875-0BC20-1AC0 SIMATIC HMI
  • Siemens 6AV6645-0CB01-0AX0 Mobile Panel
  • Siemens 6DD1607-0AA2 module
  • GE IC693MDL655 Discrete Input Module
  • ABB AI820 3BSE008544R1 Analog Input Module
  • Siemens 6EP1336-3BA10 power module
  • ABB AO810 REP3BSE008522R1 Analog Output Module
  • Siemens SIMATIC S7-400 EXM 438-1 I/O Expansion Module (6DD1607-0CA1)
  • Bently Nevada 3300 XL 8mm Proximity Sensor System
  • MOOG Rugged Motion Controller
  • GE Grid Solutions Hydran M2 (Mark III) Transformer Oil Dissolved Gas and Moisture Monitoring Device
  • Fanuc A16B-3200-0110 CNC System Module
  • ABB PM866AK01 processor unit (3BSE076939R1)
  • ABB MControl Motor and Feedline Control Unit (1TGE120011R1000)
  • ABB DSDP 140B Counter Board (5716001-ACX)
  • ABB M10x Motor Control and Protection Unit (1TNA920500R0002)
  • Foxboro Evo ™ Standard 200 Series Baseplates(PSS 31H-2SBASPLT)
  • Foxboro I/A Series Compact 200 16 Slot Horizontal Substrate (31H2C480B4)
  • DeltaV ™ Flex Connect Solutions for Foxboro ™ I/A Series 100 I/O
  • Foxboro Evo ™ FBM218 module
  • Yokogawa OpreX ™ STARDOM FCN-RTU Remote Terminal Unit
  • Yokogawa STARDOM FCN-500 Autonomous Controller
  • ABB REF54 series relay protection device
  • Honeywell Safety Manager(Release 162)
  • Emerson PR6423 8mm eddy current sensor
  • Kongsberg Maritime Seatex DARPS Transponder (relative GPS responder)
  • ABB E max series low-voltage molded case circuit breaker (Sace)
  • Woodhead BradCommunications ™ Direct-Link ™ PROFIBUS-DP network interface card
  • Schneider Electric EcoStruxure Foxboro ™ DCS Thin Client(PSS 41H-4THNCLNT)
  • GE Digital Energy Hydran 201Ti Transformer DGA Monitor
  • ProSoft MVI56E-MNET/MNETXT module
  • Foxboro ™ I/A Series Model H90 Workstation Server
  • Foxboro ™ I/A Series FBM222 Analog Input Module
  • Foxboro ™ DCS FBM214b HART ® Communication input module
  • Foxboro ™ DCS Field Device Controller 280(FDC280)
  • Schneider Electric Foxboro ™ DCS FPS480-24 Compact Power Supply
  • GE Multilin 469 Motor Protection System
  • Honeywell System 57 5704 Control System
  • Sakae toshin FCPS22AC, FCP22A, FCP30A series potentiometers
  • ABB LD 810HSE Ex Foundation fieldbus connection equipment
  • Schneider TSXCUSBFIP USB gateway (Fipway/Fipio bus)
  • KBAC series adjustable frequency drive
  • ABB CP450 Human Machine Interface (HMI)
  • ABB Ability ™ Symphony ® Plus MR series (Melody Rack) control system
  • Lennox ZHA series heat pump complete set (507257-01b)
  • Allied Telesis AT-TQ4400e Enterprise Outdoor Wireless Access Point
  • UE 54 series pressure, vacuum, and temperature switches
  • Powell PowlVac ® CDR&GCB Series 4 Vacuum Circuit Breaker
  • EMG Automation GmbH SV 1-10 servo valve
  • West 2300 1/32 DIN Indicator and Controller
  • Foxboro Evo ™ FBM242 Discrete Output Module
  • Emerson MVME6100 series VMEbus single board computer
  • Okonite Type SP-OS ITC/PLTC Instrument Cable
  • Honeywell SPS series intelligent position sensor
  • Woodward PGPL electro-hydraulic actuator/driver(37519 G version)
  • Enedo ADC7180R/ADC7181R series 800W plug-in rectifier
  • Bently Nevada 3300 XL High Temperature Proximity Detection System (HTPS)
  • Siemens SINAMICS S120 AC frequency converter
  • Emerson AMS 3210 Axis Position Monitor
  • Siemens SINAMICS DCM DC Converter and Control Module
  • Schneider Electric 31H7 series
  • ABB System 800xA wired network switch
  • Woodward ESDR 4/4T current differential protection relay
  • Meggitt Modular CPU card and input / output card
  • Meggitt MPC4 mechanical protection card
  • Meggitt Vibro Meter RPS 6U rack power module
  • Motorola MVME Series IPMC712/761 I/O Module
  • Analog Devices DS3800 Advanced NV SRAM Battery Cover
  • ABB DO02 Octal SPST Relay Module
  • GE Multilin D20/D200 Substation Controller
  • ABB PBA800 Process Bus Adapter
  • Foxboro Evo FBM237 Analog Output Module
  • Foxboro Evo FBM217 Discrete Input Module
  • Allen Bradley 1756 ControlLogix I/O Specifications Module
  • ​Molex SST-ESR2-CLX-RLL and SST-SR4-CLX-RLL communication modules
  • ABB ACS880-01-025A-3 frequency converter
  • SKiiP 1213 GB123-2DL V3 module
  • Bently 3500/60 and 3500/61 temperature modules
  • ABB ACS880-01-025A-3 frequency converter
  • Emerson DeltaV S-series Traditional I/O Modules
  • HONEYWELL EXCEL 5000 OPEN SYSTEM
  • Pepperl+Fuchs RSD-CI2-Ex8 Analog Input Module
  • Bently Nevada 3500/50M tachometer module
  • Woodward 2301A 9907 series electronic load distribution and speed controller