K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
HIMA F3501 Safety-Related Controller
❤ Add to collection

HIMA F3501 Safety-Related Controller

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

HIMatrix controllers are available for the programming tools SILworX and ELOP II Factory.  Which programming tool can be used, depends on the processor operating system of the  HIMatrix controller, refer to the following table

8588.00
¥6776.00
Weight:2.000KG
Quantity:
(Inventory: 22)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

HIMatrix controllers are available for the programming tools SILworX and ELOP II Factory.  Which programming tool can be used, depends on the processor operating system of the  HIMatrix controller, refer to the following table


HIMA F3501 Safety-Related Controller

Safety

All safety information, notes and instructions specified in this document must be strictly

observed. The product may only be used if all guidelines and safety instructions are adhered to.

This product is operated with SELV or PELV. No imminent risk results from the product itself.

The use in Ex-Zone is permitted if additional measures are taken.

2.1 Intended Use

HIMatrix components are designed for assembling safety-related controller systems.

When using the components in the HIMatrix system, comply with the following general

requirements.

2.1.1 Environmental Requirements

Requirement type Range of values 1)

Protection class Protection class III in accordance with IEC/EN 61131-2

Ambient temperature 0...+60 °C

Storage temperature -40...+85 °C

Pollution Pollution degree II in accordance with IEC/EN 61131-2

Altitude < 2000 m

Housing Standard: IP20

Supply voltage 24 VDC

1) The values specified in the technical data apply and are decisive for devices with extended

environmental requirements.

Table 3: Environmental Requirements

Exposing the HIMatrix system to environmental conditions other than those specified in this

manual can cause the HIMatrix system to malfunction.

2.1.2 ESD Protective Measures

Only personnel with knowledge of ESD protective measures may modify or extend the system

or replace devices.

Product Description

The safety-related F35 controller is a compact system in a metal housing with 24 digital inputs,

8 digital outputs, 2 counters and 8 analog inputs.

The controller is available in various model variants for SILworX and ELOP II Factory, see

Table 6.

The device is suitable for mounting in Ex-zone 2. see Chapter 4.1.6.

The device is TÜV-certified for safety-related applications up to SIL 3 (IEC 61508. IEC 61511

and IEC 62061), Cat. 4 and PL e (EN ISO 13849-1) and SIL 4 (EN 50126. EN 50128 and

EN 50129).

Further safety standards, application standards and test standards are specified in the

certificates available on the HIMA website.

3.1 Safety Function

The controller is equipped with safety-related digital inputs and outputs, safety-related counters

and safety-related analog inputs.

3.1.1 Safety-Related Digital Inputs

The controller is equipped with 24 digital inputs. The state (HIGH, LOW) of each input is

signaled by an individual LED.

i The LEDs for the digital inputs are activated by the program if the F35 is in RUN.

The input signals are captured analogically and made available as INT values from 0...3000

(0...30 V) to the program.

i The digital inputs must not be used as safety-related analog inputs!

Configurable thresholds are used to generate BOOL values.

The default setting is:

Low level: < 7 V High level: > 13 V

The thresholds are set using system parameters, see Table 43 and Table 44. A difference of at

least 2 V must be maintained between the thresholds.

Mechanical contacts without own power supply or signal power source can be connected to the

inputs. Potential-free mechanical contacts without own power supply are fed via an internal

short-circuit-proof 24 V power source (LS+). Each of them supply a group of 8 mechanical

contacts. Figure 1 shows how the connection is performed.

With signal voltage sources, the corresponding ground must be connected to the input (L-), see

Figure 1.

Figure 1: Connections to Safety-Related Digital Inputs

For the external wiring and the connection of sensors, apply the de-energized-to-trip principle.

Thus, if a fault occurs, the input signals adopt a de-energized, safe state (low level).

An external wire is not monitored, however, an open-circuit is considered as safe low level.

3.1.1.1 Reaction in the Event of a Fault

If the device detects a fault on a digital input, the user program processes a low level in

accordance with the de-energized to trip principle.

The device activates the FAULT LED.

In addition to the channel signal value, the user program must also consider the corresponding

error code.

The error code allows the user to configure additional fault reactions in the user program.

3.1.1.2 Line Control

The detection of short-circuits and open circuits cannot be configured for the F35 system, e.g.,

on EMERGENCY STOP inputs complying with Cat. 4 and PL e in accordance with EN

ISO 13849-1.

Line monitoring for digital outputs is possible, see Chapter 3.1.4.1.


  • OMRON C-series/CVM1/CV series analog I/O units
  • Siemens SINUMERIK 840C+SIMODRIVE 611-D Installation Guide
  • ABB ACS550 frequency converter
  • OMRON SYSMAC NX series NX1P2 CPU unit
  • Fuji FRENIC Mini Inverter
  • Braided Flexible Connections
  • Mecc Alte MC200 Controller
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 Automation System
  • Schneider TeSys Giga GV5/GV6 motor protection circuit breaker
  • Eaton Freedom NEMA Contactor and Starter Specification
  • OMRON D4SL-N Safety Door Switch (Including Locking) Specification
  • NI CompactRIO Embedded System
  • I/O module of Emerson Ovation distributed control system
  • MITSUBISHI MELSEC A series PLC(MELSEC-A)
  • Specification for Automation Direct DL06 Series Micro PLC (D0-06DD1)
  • IFM CR2530 SmartController Installation Manual
  • OMRON FH/FHV series visual sensor controller
  • PILZ PDP67 F 4 code operation instructions
  • Panasonic FP-X series PLC
  • OMRON CK3W-AX Axis Interface Unit Specification
  • EPSON RC90/RC90-B Robot Controller
  • Nthytronic Group iRTUe Modular I/O Expansion Unit
  • Schneider Altivar Machine ATV320 frequency converter
  • Eaton Cutler Hammer Pull SPB Automatic Transfer Switch (ATS) Operation and Maintenance
  • GFS Corp EVO-SP 2600 Diesel Generator Set Natural Gas Conversion System Specification
  • OMRON SYSMAC CJ Series CJ2 CPU Unit Hardware
  • Lenze ECS servo frequency converter
  • GE EX2100e excitation control system 35A/120A regulator
  • OMRON G3PW Power Controllers
  • MITSUBISHI FX3GE MELSEC Compact PLC
  • BECKHOFF EP23xx series IP67 protection level EtherCAT Box digital input/output module
  • MITSUBISHI MDS-A/B Series CNC AC Servo/Spindle System
  • TOYO's full range of valve products
  • SIEMENS SIMODRIVE 611 Universal/Universal E Full Series Digital Drive Control Board
  • SIEMENS SINUMERIK 840C SIMODRIVE 611-D Installation Guide
  • FANUC 0i Model F Universal CNC Control System
  • Schneider Modicon TM3 Expansion I/O modules for Modicon M221, M241, M251 and M262 controllers
  • R&S®EPL1000 EMI TEST RECEIVER
  • Baum ü llerb maXX series modular servo drive and automation platform
  • Huichuan AM600 motion controller
  • Allen Bradley Ultra3000 Servo System Design Guide
  • NEC NL8060BC26-17 LCD Module
  • ABB Jokab Pluto Safety PLC
  • OMRON NE1A Series Secure Network Controller Operation Manual
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-2200/2210/2220 Compact FieldPoint Intelligent Real time Controller
  • Installation Instructions for KEYENCE XG-8000 Series Line Scan Camera Version Vision System
  • Omron G9SX series flexible safety unit
  • OMRON SYSMAC CPM1A series programmable controller
  • ABB ACH550 frequency converter installation, operation and maintenance instructions
  • IDEC MicroSmart FC6A PLC CPU Module
  • Gefran GILOGIK II Distributed I/O and Control System
  • GE VersaMax Nano/Micro PLC
  • Nastyaer GIV50-11 Position Limit Switch
  • Rockwell Trusted T8111 TMR Processor
  • TIANMA NL8060BC21-11KG 8.4-inch TFT LCD module
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H series DC/DC power module
  • SIEMENS QBE3000-D/QBE3100-D Differential Pressure Sensor
  • Huichuan H3U series PLC
  • Phoenix ILC 1X1 Series Inline Controller
  • Allen‑Bradley Lifeline ™ 4 Pull rope emergency stop switch
  • Gardner Denver DELCOS 3100 Controller
  • Mitsubishi GOT2000 series graphic operation terminal
  • EBW Series current detection resistor
  • Mitsubishi MELSEC AnS (H) series CPUs
  • Honeywell TN3801 Electric Pneumatic Liquid Level Measurement Cabinet
  • ABB PSR/PSRC/PSE/PSTX series soft starter
  • GE HYDRAN ® 201i Transformer Online Monitoring System
  • ABB NextMove ESB-2 motion controller
  • CAREL PGD graphic display handheld device
  • Hiossen EK implant system
  • Eaton 9PX Series UPS Installation and User Instructions
  • Airlec RYP series precision pressure reducing valve
  • Schneider Modicon M258 Logic Controller
  • KEYENCE XG-7000/8000 Series Visual System New Function Manual
  • Alfa Laval EPC 70 upgrade for separators with EPC 50
  • Nidec Unidrive M700/M701/M702 frequency converter
  • Mitsubishi A171SCPU Motion Controller
  • YASKAWA DX200 Robot Function Pack Manual
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Cambridge Lee Copper Tube
  • TAIYO LX series brushless AC generator
  • Automate Direct DL06 Micro PLC
  • Kepco BOP Bipolar Power Supply Operating Instructions
  • Pilz PNOZmulti Classic/Mini Safety Mini Controller
  • HMS Airbus X-gateway Industrial Protocol Gateway
  • Nidec Control Techniques Unidrive SP AC Variable Frequency Governor
  • GE SPEEDTRONIC ™ Mark VI Gas/Steam Turbine Control System
  • Instructions for using LK-TECH MGv2 servo motor
  • Zebra EPL2 Programming Language Programming Guide
  • How to install Elmo Gold Whistle digital servo drive?
  • MITSUBISHI ELECTRIC FR-D700 frequency converter
  • Edwards EST3 Emergency Communication and Life Safety Platform
  • ABB ACS380 mechanical frequency converter
  • MITSUBISHI ELECTRIC MELSEC iQ-R/System Q/L series PLC family
  • Rockwell Automation Bulletin 5069 Series Controllers
  • CODESYS Control Win SL
  • ABB AC 800M controller and communication interface
  • Honeywell 7800 Series EC/RM7830A/7850A Combustion Relay Module
  • Rockwell AutoMax Distributed Power Drive System Manual
  • SNO 4062 K/KM safety relay
  • World Encoders iPHD/iHDW series handheld electronic handwheel
  • Copes Vulcan turbine bypass system (CV-1163)
  • ZF Marine MM9000 ClearCommand Marine Propulsion Control System
  • Pro face GP-2400/2500/2600 Series Operating Manual
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller
  • Metso DNA Device Status Monitoring System
  • ABB Millmate Rolling Mill Force Measurement System
  • Reliance Electric GV3000/SE AC Inverter
  • EUCHNER handheld operating unit and electronic handwheel
  • GE Fanuc Automation VersaMax ® I/O and Control
  • Microchip dsPIC30F series 16 bit high-performance digital signal controller
  • Milacron ELEKTRON 400/500/600 series fully electric injection molding machine
  • PRECILEC RE.0444N series DC tachometer generator
  • Mitsubishi GOT2000/GOT1000 series serial communication unit
  • Keyence GS series safety interlock switch
  • GE AT868 AquaTrans ™ Single/dual channel ultrasonic water flow transmitter
  • MITSUBISHI ELECTRIC GOT1000 Series Connection Manual
  • Allen Bradley Guardmaster GSR Safety Relay
  • Delta AH500 PLC Operating Instructions
  • Pilz PNOZmulti series safety control system
  • Operation Instructions for Pilz PNOZ XV3P Safety Relay
  • Pilz PZE 9 Safety Relay Expansion Module
  • SCHNEIDER TSX Premium P57 Processor and Discrete I/O Modules
  • KONGSBERG High Precision Acoustic Positioning – HiPAP®