K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
GE FANUC IC698CPE030/CPE040 Central Processing Unit
❤ Add to collection

GE FANUC IC698CPE030/CPE040 Central Processing Unit

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

The RX7i CPUs are programmed and configured by the programming software to perform real time  control of machines, processes, and material handling systems. The CPU communicates with I/O and  smart option modules over a rack-mounted backplane using the VME64 Standard format. It  communicates with the programmer and HMI devices via the embedded Ethernet ports or a serial port  using SNP Slave protocol.

12883.00
¥12500.00
Weight:2.400KG
Quantity:
(Inventory: 22)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

The RX7i CPUs are programmed and configured by the programming software to perform real time  control of machines, processes, and material handling systems. The CPU communicates with I/O and  smart option modules over a rack-mounted backplane using the VME64 Standard format. It  communicates with the programmer and HMI devices via the embedded Ethernet ports or a serial port  using SNP Slave protocol.


GE FANUC IC698CPE030/CPE040 Central Processing Unit

CPE030:

600MHz Pentium-M microprocessor with 64 MB of user memory and 64 MB of user flash

CPE040:

1800MHz Pentium-M microprocessor with 64 MB of user memory and 64 MB of user flash

Features

■ Contains 64 Mbytes each of battery-backed user memory and non-volatile flash user memory for

user data (program, configuration, register data, and symbolic variable) storage.

■ Access to bulk memory via reference table %W.

■ Configurable data and program memory.

■ Programming in Ladder Diagram, C, Structured Text, and Function Block Diagram.

■ Auto-located Symbolic Variables that can use any amount of user memory.

■ Support for Series 90-70 discrete and analog I/O, communications, and other modules. For a list

of modules supported, refer to the PACSystems RX7i Installation Manual, GFK-2223.

■ Support for all non-GE Fanuc VME modules supported by Series 90-70.

■ PLC data monitoring over the web. Allows a combined total of up to 16 web server and FTP

connections.

■ Up to 512 program blocks. Maximum size for a block is 128KB.

■ Test Edit mode that allows you to easily test modifications to a running program.

■ Bit-in-word referencing

■ Battery-backed calendar clock.

 CPU and module firmware upgrades via Winloader through CPU’s RS-232 or RS-485 serial port.

■ Three isolated serial ports: an RS-485 serial port, an RS-232 serial port, and an RS-232 Ethernet

station manager serial port.

■ An embedded Ethernet interface with:

− Data exchange using Ethernet Global Data (EGD)

− TCP/IP communication services using SRTP

− Modbus TCP server

− Full PLC programming and configuration services

− Comprehensive station management and diagnostic tools

− Two full-duplex 10BaseT/100BaseT/TX (RJ-45 Connector) ports with an internal network

switch providing auto-negotiated network speed, duplex mode, and crossover detection.

Specifications

Note: For environmental specifications and compliance to standards (for example, FCC or European Union Directives),

refer to Appendix A of the PACSystems RX7i Installation Manual, GFK-2223.

Battery: Memory retention Estimated 30 days using an IC693ACC302 Auxiliary Battery Module

at 20ºC.

For details on the operation of the Auxiliary Battery Module, refer to

the datasheet, GFK-2124.

Note: The IC698ACC701 RX7i Replacement Battery is not

compatible with the CPE030 or CPE040 CPU modules.

Program storage Up to 64 Mbytes of battery-backed RAM

64 Mbytes of non-volatile flash user memory

Power requirements: CPE030

CPE040

+5 VDC: 3.2 Amps nominal

+12 VDC: 0.003 Amps nominal

-12 VDC: 0.003 Amps nominal

+5 VDC: 6.8 Amps nominal

+12 VDC: 0.003 Amps nominal

-12 VDC: 0.003 Amps nominal

Operating temperature: CPE030

CPE040

0 to 50°C (32°F to 122°F)

0 to 60°C (32°F to 140°F) with fan tray

0 to 60°C (32°F to 140°F), fan tray required

Boolean execution speed, typical: CPE030

CPE040

0.069ms per 1000 Boolean contacts/coils

0.02391ms per 1000 Boolean contacts/coils

Time of Day Clock accuracy Maximum drift of ±2 seconds per day

Elapsed Time Clock (internal timing) accuracy ±0.01% maximum

Embedded communications RS-232. RS-485. Ethernet interface

Serial Protocols supported Modbus RTU Slave, SNP, Serial I/O

Ethernet Ports Embedded auto-sensing 10/100 Mbps half/full duplex Ethernet

interface

VME Compatibility System designed to support the VME64 standard ANSI/VITA 1

Program blocks Up to 512 program blocks. Maximum size for a block is 128KB.

Memory

(For a detailed listing of memory areas, refer to

the CPU Reference Manual, GFK-2222.)

%I and %Q: 32Kbits for discrete

%AI and %AQ: configurable up to 32Kwords

%W: configurable up to the maximum available user RAM

Managed memory (Symbolic and I/O variables combined):

configurable up to 10 Mbytes

Ethernet Interface Specifications

Web-based data monitoring Up to 16 web server and FTP connect

Release History

Catalog Number Date CPU Firmware Version Ethernet Firmware Version Comments

IC698CPE040-AA Dec. 2005 CPU: 3.60 Ethernet: 3.60 Initial Release

IC698CPE030-AA April 2006 CPU: 3.60 Ethernet: 3.60 Initial Release

CPU Functional Compatibility

Subject Description

Programmer Version

Requirements

Proficy™ Machine Edition Logic Developer PLC 5.5 SIM 6 or later must be used for

Release 3.60 new features.

C Toolkit Compatibility C Toolkit Release 3.50 Build 34A1 is required for new features in PACSystems Release 3.50

(Use of variables in C Blocks).

Battery Pack

Compatibility

The Auxiliary Battery Module (IC693ACC302A) must be used with the PACSystems RX7i

CPE030/CPE040 CPU for memory retention. The RX7i three-cell lithium battery pack

(IC698ACC701) cannot be used with the CPE030 and CPE040 CPUs.

Series 90-70 Expansion

Rack Compatibility

Series 90-70 expansion racks are supported by the PACSystems RX7i.

PACSystems RX7i CPUs and the RX7i Ethernet Module do not operate in a Series 90-70 rack.

Series 90-70 Main Rack

Compatibility

Series 90-70 Main Racks cannot be used in a PACSystems RX7i system.

PACSystems RX7i CPUs and the RX7i Ethernet Module do not operate in a Series 90-70 rack.

Series 90-70 Module

Compatibility

For a list of modules supported by the RX7i CPUs, refer to the PACSystems RX7i Installation

Manual, GFK-2223.

Insulating Strips for High

Voltage Modules

An insulator strip is required on a high voltage module that is installed to the immediate right of

a module with a metal faceplate. Insulating strips should be installed on the following modules

that have versions earlier than:

IC697MDL240D
IC697MDL640E

IC697MDL241D
IC697MDL340G

IC697MDL250G
IC697MDL341E

IC697MDL251E
IC697MDL350F

Note: Current versions of these modules are shipped with the insulators installed. The strip

is visible on the back of the printed wiring assembly. The RX7i rack is shipped with an Insulator

Kit that includes enough parts to update three Series 90-

  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives
  • ABB MNS iS motor control center
  • ABB Condition MonitoringMService