K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
Emerson M-series Virtual I/O Module2
❤ Add to collection

Emerson M-series Virtual I/O Module2

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

Introduction The DeltaV M-series Virtual I/O Module 2 (VIM2)  provides nonintrusive simulation of the DeltaV Mseries I/O Cards and digital bus field devices for  process simulation when used with MYNAH  Technologies’ MiMiC Simulation Software. DeltaV  Control strategies and system configurations can be  fully tested with this powerful simulation interface.

11000.00
¥10000.00
Weight:3.220KG
Quantity:
(Inventory: 12)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

Introduction The DeltaV M-series Virtual I/O Module 2 (VIM2)  provides nonintrusive simulation of the DeltaV Mseries I/O Cards and digital bus field devices for  process simulation when used with MYNAH  Technologies’ MiMiC Simulation Software. DeltaV  Control strategies and system configurations can be  fully tested with this powerful simulation interface.


Emerson M-series Virtual I/O Module2

The VIM2 also provides an interface to Ethernet I/O

networks and devices that use the Modbus TCP/IP

or Ethernet/IP protocol drivers. DeltaV M-series

controllers can read and write signals from plant

floor devices connected to Ethernet I/O networks

such as PLC’s, Motor Control Centers, and Weigh

Scales.

Benefits

Non-Intrusive DeltaV I/O simulation. Use the VIM2

in conjunction with the MYNAH Technologies’ MiMiC

Simulation Software to simulate your DeltaV M-Series

I/O and digital bus field devices.

 Supports DeltaV I/O modules. Provides completely

non-intrusive simulation of all DeltaV M-series I/O

Modules. Supports autosensing of I/O and accurate

testing of controller loading. DeltaV configuration can

be fully tested without modifying the control

strategies.

 Digital bus support. Provides simulation of all

DeltaV Digital Busses and Foundation Fieldbus

function blocks. Supports Foundation Fieldbus control

in the field configuration testing.

 Powerful simulation solution. Provides full

simulation of up to 64 DeltaV I/O modules per

controller. Simulation execution is fast and efficient;

the DeltaV controller thinks it’s talking with real IO.

Powerful integration solution. Use the VIM2 in

conjunction with the MYNAH Ethernet I/O drivers to

integrate your DeltaV system with your Ethernet I/O device

networks.

 Large device capacity. Each VIM emulates four

DeltaV Serial Cards and support up to 128 Serial

Card Datasets of information from 32 network devices

in simplex installations and 16 devices in redundant

installations. Communication over the Ethernet I/O

device network is fast and efficient.

 Flexible networking. User configurable IP

addressing allows the VIM2 to be used in almost any

plant environment regardless of networking scheme.

The VIM2 and the Ethernet I/O devices must be on

the same IP subnet to communicate.

 1:1 Redundancy. Redundancy can be added to any

Ethernet I/O system by adding a second VIM2 and

configuring the two cards as a redundant pair. The

VIM2 appears as four redundant DeltaV Serial Card

pairs. Automatic switchover of primary to standby

cards is handled like the DeltaV Serial Card. The

operator is given clear notification of a switchover at

the operator display. Manual switchover can be

controlled in DeltaV Diagnosti

Automatic updates. Simulation I/O driver updates for

the VIM2 are included with the MiMiC software

releases. Updates are quick and easy over the

simulation network.

 Seamless Ethernet I/O integration. When used with

the MYNAH Ethernet I/O drivers, the VIM2 is seen by

the DeltaV M-series controller as four DeltaV Serial

Cards. Commissioned VIM2s are auto-sensed by the

DeltaV controller as DeltaV Serial Cards.

 Configured in DeltaV Explorer. Serial dataset

configuration used for Ethernet I/O integration is done

in the DeltaV Explorer in the same manner as a

DeltaV Serial Card. Ethernet I/O signals can be used

in DeltaV Control Modules, displayed on DeltaV

Operate graphics and stored in the DeltaV

Continuous Historian.

 Intuitive setup. The VIMNet Explorer application

provides plug-n-play capability making setup of the

VIM2 easy and intuitive. Graphical, drag-n-drop,

functionality makes setting up multiple VIM2s almost

effortless. VIMNet Explorer is integrated with DeltaV

Explorer to make setup of the VIM2 easy and intuitive.

Modular, flexible packaging. The VIM2 mounts in the

same manner as the DeltaV controller. It mounts in the

controller slot of a DeltaV 2-wide horizontal or 4-wide

vertical carrier and uses a standard DeltaV Power Supply.

The advanced design of the VIM2 will provide years of

uninterrupted use.

IO Simulation When used with MYNAH’s MiMiC

Simulation Software, the VIM2 supports I/O simulation all

DeltaV M-series I/O cards including classic IO, Foundation

Fieldbus, ProfibusDP, DeviceNet, ASi-bus and Serial.

MiMiC Simulation Software provide dynamic simulation for

DeltaV system software acceptance testing and operator

training. The MiMiC software works by simulating the

DeltaV I/O. It also simulates field devices using

Foundation Fieldbus, ProfibusDP, DeviceNet and AS-i

buses. In order for MiMiC to do this, the real I/O cards are

disconnected from the control system. The MiMiC driver

writes to the I/O subsystem of the DeltaV controller.

Process models in MiMiC simulate realistic process

reactions to control system output signals.

Each process controller being simulated uses one MiMiC

Dataset. A MiMiC server can have up to 32 datasets or

ports. Each dataset can support up to 4000 MiMiC

simulation tags.

The I/O simulation driver is provided with the VIM2

hardware, pre-loaded in the VIM2. The MiMiC Simulation

Software must be purchased separately from MYNAH

Technologies. Technical support for the MiMiC Simulation

Software and I/O simulation driver is provided by MYNAH

Technologies.

Ethernet I/O Integration When used with the MYNAH

Ethernet I/O drivers, the VIM2 can communicate with

high-speed Ethernet networks over Modbus TCP or

Ethernet/IP. When the VIM2 is configured with the

appropriate Ethernet I/O driver, the DeltaV Controller autosenses a commissioned VIM2 as four DeltaV Serial Cards.

 In simplex installations these cards will be sensed in

slots 57-60 or 61-64.

 In redundant installations the redundant pairs will be

sensed in slots 57 to 64.

Configuration of the I/O signals from the commissioned

VIM2 is done in the DeltaV Explorer in the same manner

as a DeltaV Serial Card.

VIMNet Explorer. The VIMNet Explorer utility allows the

user to commission the VIM2. setup primary and

redundant VIM2s, and the Ethernet I/O network. The useris able

  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives
  • ABB MNS iS motor control center
  • ABB Condition MonitoringMService