K-WANG
High speed counter module
Internal square wave oscillator output, which can be used as the counting input for the first counter or as a measurement
The time benchmark. The default output value is 1KHz
• Can perform continuous or single counting
Continuous mode: restart when the counter reaches its limit value
Single time mode: Stop when the counter reaches its limit value
Each count result is stored separately
The CPU can read data or set the application program for each counter
This module can quickly process high-speed input data, independently or with CPU control output, and can achieve the following
List any of the three counting methods.
Type A four independent pulse counters
B-type two A Quad B counters
C-type composite counter
GE FANUC IC660BBA101 Temperature analog module
Characteristics of high-speed counter module
Basic characteristics
Working temperature: 0 ° C to 60 ° C
Storage temperature -40 ° C to 100 ° C
Humidity ranging from 5% to 95%
Working voltage 93 to 132VAC or 10 to 30VDC
Power load (AC) 60 mA standard/250 mA maximum
Power load (DC) 200 mA standard/300 mA maximum @ 12V
Diagnostic fault switch
input
Voltage range 5-30VDC
Points 12 (for counting up to 4 channels)
Input type positive logic
Input impedance 4.0K ohms
Optional input response time high-frequency 2.5 µ S
Low frequency 12.5ms
Counting frequency high frequency 200KHz
Low frequency 40Hz
output
Voltage range 4.75V DC to 5.25V DC @ 200mA
Points 4
Output type positive logic
Turn off leakage current up to 10mA
Maximum switching frequency once per second
Order number description
IC660BBD120 high-speed counter module
Power monitoring module
By using current and voltage transformers, the effective values of current and voltage, power, power factor, energy, etc. can be measured
Power parameters, each module provides a three-phase voltage detection circuit and a three-phase current detection circuit.
The power monitoring module sends data to the main controller every 0.5 seconds through digital to analog conversion, and can also be connected
The handheld programmer displays the status of power monitoring data.
Characteristics of power monitoring module
Working temperature: 0 ° C to 60 ° C
Storage temperature -40 ° C to 100 ° C
Humidity ranging from 5% to 95%
Voltage input
Maximum number of circuits 3
Voltage range 0-120VAC
Voltage measurement accuracy 0.25% full range
Current input
Maximum number of circuits 3
Current range 0-5A
Current measurement accuracy 0.5% full range
Power measurement accuracy 0.75% full range
Diagnose overcurrent, input exceeds limit
The module power consumption is 115 VAC/230VAC (90-265VAC), 47-63Hz or 125VDC (100-150VDC), with a maximum of 35VA
Order number description
IC660BPM100 power monitoring module
Bus switching module
Bus Switching Module (BSM) is used to connect Genius I/O modules (up to 8 modules) to dual
Genius bus
Multiple Bus Switching Modules (BSMs) can be used on the same dual bus
• Simple and reliable operation
The operation of the Bus Switching Module (BSM) is controlled by the Genius I/O module
Bus Switching Module (BSM) can be forced or canceled by CPU or handheld programmer
The LED indicator light indicates which bus is currently in operation
BUS
INTERFACE
MODULE
BUS
INTERFACE
MODULE
BUS A
BUS B
BSM
BSM
a42361
Dual Genius bus
Connection diagram
Characteristics of Bus Switching Module
*The module must operate at 24VDC
Order number
IC660BSM021 Bus Switching Module (24VDC/48VDC)
IC660BSM120 bus switching module (115VAC/125VDC)
Handheld monitor HHM
Handheld monitor HHM is a convenient monitoring configuration tool used for configuring and monitoring Genius I/O modules and Genius bus parameters.
LCD display screen can display information of 4 × 16 characters
Multiple languages to choose from: English, German, French, Italian
A keyboard with up to 20 membrane keys
The working mode of the handheld programmer can be switched through the key switch to protect Genius parameter configuration
The handheld monitor HHM can be powered by a battery or by 115VAC or 230VAC
Handheld monitor HHM can be used to display:
I/O data of any device on the Genius bus
• Diagnostic information
Bus scanning time
Description of any device on the Genius bus
Global data address
• Memory data of CPU on Genius bus
At the same time, the handheld monitor HHM can also be used to configure devices, clear fault tables, force I/O, dual bus selection, etc.
User name | Member Level | Quantity | Specification | Purchase Date |
---|