K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB 216GD61A HESG324436R3/A generator protection digital control unit
❤ Add to collection

ABB 216GD61A HESG324436R3/A generator protection digital control unit

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

For feeders with single phase tripping and autoreclosure, the time setting for the breaker pole discrepancy

protection must be greater than the reclosure time. The discrepancy factor is the maximum permissible

difference between the amplitudes of two phases.

25000.00
¥25000.00
Weight:3.330KG
Quantity:
(Inventory: 25)
Consultation
Accessories
  • Emerson M-series
    Original :¥10000.00
    With a price :¥10000
    Quantity  
  • YOKOGAWA FCN Aut
    Original :¥8574.00
    With a price :¥8574
    Quantity  
  •   
    Original :¥
    0.00
      
      With the total price :¥
    0.00
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

For feeders with single phase tripping and autoreclosure, the time setting for the breaker pole discrepancy

protection must be greater than the reclosure time. The discrepancy factor is the maximum permissible

difference between the amplitudes of two phases.




ABB 216GD61A HESG324436R3/A generator protection digital control unit

Table 20 Breaker pole discrepancy protection (51/62PD)
Setting range
Time delay
Discrepancy factor
0.1 IN to 2.0 IN in steps of 0.1 IN, default 0.2 IN
100 ms to 10000 ms in steps of 100 ms, default 1500 ms
0.01* Imax to 0.99 * Imax in steps of 0.01 * Imax, default 0.6 * Imax
For feeders with single phase tripping and autoreclosure, the time setting for the breaker pole discrepancy
protection must be greater than the reclosure time. The discrepancy factor is the maximum permissible
difference between the amplitudes of two phases.
Table 21 Current release criteria (51)
Setting range (per feeder) 0.1 IN to 4.0 IN in steps of 0.1 IN, default 0.7 IN
If the current release criteria is not activated, the tripping command (“21110_TRIP”) is given independent
of current (standard setting).
The current release criteria only allows the trip of a circuit breaker if the feeder current value is above the
setting value of the enabling current. This value can be individually selected for each bay.
Table 22 Voltage release criteria (27/59)
U< Setting range (per feeder)
U0> Setting range (per feeder)
0.2 UN to 1.0 UN in steps of 0.05 UN, default 0.7 UN
0.1 UN to 1.0 UN in steps of 0.05 UN, default 0.2 UN
If the voltage release criteria is not activated the tripping command (“21110_TRIP”) is given independent
of voltage (standard setting).
The voltage release criteria is used as an additional criterion for busbar protection (as well as for the other
station protection functions) and operates per zone. It can be used as U< or U0> or in combination.
Table 23 Check zone criterion (87CZ)
Min. fault current pick-up setting (Ikmin) 500 to 6000 A in steps of 100 A
Stabilizing factor (k) 0.0 to 0.90 in steps of 0.05
CT ratio per feeder Feeder 50 to 10 000/1 A,
50 to 10 000/5 A, adjustable via HMI500
The check zone is used as an additional release criterion for busbar protection and operates zone-independent.
For delaying pick-up or reset or for integrating 1 binary signal
Provision for inverting the input
4 independent parameter sets
Settings:
Pick-up or reset time 0 to 300 s in steps of 0.01 s

Integration yes/no

Table 25 Logic

Bay level functions for Back-up/Main 2 REB500sys
Logic for 4 binary inputs with the following 3 configurations:
1. OR gate
2. AND gate
3. Bistable flip-flop with 2 set and 2 reset inputs (both OR gates), resetting takes priority
 4 independent parameter sets.
All configurations have an additional blocking input.
Provision for inverting all inputs.
Table 26 Definite time over- and undercurrent protection (51)
Over- and undercurrent detection
Single or three-phase measurement with detection of the highest, respectively lowest phase current
2nd harmonic restraint for high inrush currents
4 independent parameter sets
Settings:
Pick-up current 0.2 to 20 IN in steps of 0.01 IN
Delay 0.02 to 60 s in steps of 0.01 s
Accuracy of the pick-up setting (at fN) ±5%
Reset ratio
overcurrent
undercurrent
>94% (for max. function)
<106% (for min. function)
Max. operating time without intentional delay 60 ms
Inrush restraint
pick-up setting
reset ratio
optional
0.1 I2h/I1h
0.8
Table 27 Inverse time overcurrent protection (51)
Single or three-phase measurement with detection of the highest phase current
4 independent parameter sets
Inverse time characteristic
(acc. to B.S. 142, IEC 60255-3 with extended
setting range)
normal inverse
very inverse
extremely inverse
long time inverse
t = k1 / ((I/IB)
C - 1)
c = 0.02
c = 1
c = 2
c = 1
or RXIDG characteristic t = 5.8 - 1.35 · In (I/IB)
Settings:
Number of phases 1 or 3
Base current IB 0.04 to 2.5 IN in steps of 0.01 IN
Pick-up current Istart 1 to 4 IB in steps of 0.01 IB
Min. time setting tmin 0 to 10 s in steps of 0.1 s
k1 setting 0.01 to 200 s in steps of 0.01 s
Accuracy classes for the operating time
according to B.S. 142, IEC 60255-3
RXIDG characteristic
E 5.0
±4% (1 - I/80 IB)
Reset ratio 95%
  • FOXBORO FDC280 RH101FQ DCS Modules
  • ABB LDGRB-01 Highly functional controller module
  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives