K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
Honeywell LV RTP Cable (32/16 channel) (1.0M, 3.28ft) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-3310
❤ Add to collection

Honeywell LV RTP Cable (32/16 channel) (1.0M, 3.28ft) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-3310

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

NOTE: In the diagram below, the white cut-outs represent the cut-outs on the modules that

accommodate tabs on the Terminal Block. That is, all key-tabs that line up with the white cutouts on the diagram should be retained, and all other tabs should be removed.

18000.00
¥18000.00
Weight:3.550KG
Quantity:
(Inventory: 19)
Consultation
Accessories
  • ABB-07AC91-Analo
    Original :¥16475.00
    With a price :¥16475
    Quantity  
  • ABB-AC31 91serie
    Original :¥16475.00
    With a price :¥16475
    Quantity  
  •   
    Original :¥
    0.00
      
      With the total price :¥
    0.00
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

NOTE: In the diagram below, the white cut-outs represent the cut-outs on the modules that

accommodate tabs on the Terminal Block. That is, all key-tabs that line up with the white cutouts on the diagram should be retained, and all other tabs should be removed.




Honeywell LV RTP Cable (32/16 channel) (1.0M, 3.28ft) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-3310

NOTE: In the diagram below, the white cut-outs represent the cut-outs on the modules that

accommodate tabs on the Terminal Block. That is, all key-tabs that line up with the white cut outs on
the diagram should be retained, and all other tabs should be removed.

The orientation of the diagrams below corresponds to the picture of the terminal block, shown in
the previous picture.
Diagrams for I/O Module Key-Tabs
Step Procedure Comments Reference
5 If installing High Level 16 channel Analog Input module, set its SW1 and SW2 DIP switches to
ON. This connects an internal 250 ohm resistor.
A small slotted screwdriver or paperclip works well; avoid using pencils.
6 If installing 8- or 16-channel Analog Output module, set its DIP switch as follows. (Switch is
located at edge of module, marked “SW1”.)
 For internal rack power, set DIP switch to ON.
 For external power (18-36V), set DIP switch to OFF (default).
Note: 24VDC external power is required if using 6 or more 8-pt. AO modules or 3 or more 16-pt.
AO modules.
A small slotted screwdriver or paperclip works well; avoid using pencils.
8-16 Analog output Channels require loop power for open loop detection
Step Procedure Comments Reference
7 If installing a PFQ module, set its Input 1, Input 2 and Index DIP switches to differential or single
ended mode. Inputs mode need not match index mode. See below for switch positions.
Switch location on PFQ module:
Settings (using Input 1 as example)
Single ended (factory setting):
1 and 2 (SINGLE) = ON, 3 and 4 (DIFF) = OFF
Differential:
1 and 2 (SINGLE) = OFF, 3 and 4 (DIFF) = ON
Step Procedure Comments Reference
8 Connect wire-tie into the
top and/or bottom of the
Rack.
Form a bend in each wire
to provide strain relief, and
secure the wire bundle
with the tie.


Step Procedure Comments Reference
9 Install I/O modules in
racks. Be sure to follow
placement guidelines
under Heat Rise De-rating
page 52.
10 Install I/O module, install
appropriate terminal block.
11 In each slot location not
occupied by an I/O
module, install a Filler
Block cover, Part number
900TNF-0001.
Note: The Filler Block Cover looks much like an I/O Terminal
Block assembly, except that it does not include the wire
terminating block (screw terminals). The Filler Block mounts in
the same manner as a Terminal Block (with captured screws at
top and bottom). Blank labels are provided for mounting in the
hinged door.
I/O Terminal Block Wiring Diagrams
Universal Analog Input Module Wiring
The Universal Analog Input Module has eight inputs, which can include any combination of the following
input types: RTD, TC, Ohms, Millivolt, Volt, or Milliamp. Figure 43 shows wiring examples of each of the
analog input types. An example of wiring for eight TC inputs is given in Figure 45.
Specifications for this module and for other modules are given in the Specifications section of this manual.
ATTENTION
To indicate sensor failure the Analog Input software will output a warning if
thermocouple resistance > 80 ohms. Use appropriate gauge wiring to prevent
inaccurate failure warnings.
Table 15 – Typical Thermocouple resistance in Ohms per Double Foot @ 68 degrees F
AWG No. Diameter
inches
Type K Type J Type T Type E Type S
Pt/ PT110
Type R
Pt/ PT113
Type W5/
W26
Type W/
W26
10 0.102 0.058 0.034 0.029 0.069 0.018 0.018 0.023 0.020
12 0.081 0.091 0.054 0.046 0.109 0.028 0.029 0.037 0.031
14 0.064 0.146 0.087 0.074 0.175 0.045 0.047 0.058 0.049
16 0.051 0.230 0.137 0.117 0.276 0.071 0.073 0.092 0.078
18 0.040 0.374 0.222 0.190 0.448 0.116 0.119 0.148 0.126
20 0.032 0.586 0.357 0.298 0.707 0.185 0.190 0.235 0.200
24 0.0201 1.490 0.878 0.7526 1.78 0.464 0.478 0.594 0.560
26 0.0159 2.381 1.405 1.204 2.836 0.740 0.760 0.945 0.803
30 0.0100 5.984 3.551 3.043 7.169 1.85 1.91 2.38 2.03
Table values are shown as a reference only; actual values may vary. Consult manufacturer specifications.
Isolation
This module has eight inputs, which are isolated except for RTD current sources.
RTD Inputs
RTD inputs share current sources (two RTD inputs per source), as shown in
Figure 42, Figure 43, and Figure 44.
For example, the current source for the RTD input at channel one (terminals 1 and 2) is terminal 3 (IRTD 1 &
2). This same current source (IRTD 1 & 2) is also used for an RTD input at channel two (terminals 4 and 5).
OHMs Inputs
Ohms inputs are wired similar to 2-wire RTD inputs. That is, they require a current source, and thus must
use one of the IRTD current sources. Also, two terminals are jumpered together as they are for two-wire
RTD inputs.
Analog channels wired for Ohms inputs differ from RTD inputs in these aspects:
 Ohms inputs connect to variable resistance devices other than RTDs, and
 Ohms inputs are configured in Designer Software as Ohms inputs, rather than as RTD inputs.
Examples of wiring for resistance inputs are given in Figure 46 .
Shield Grounding
Shields must be grounded as described under Shield Grounding at the beginning of this section.
Hazardous voltages exist at terminal blocks.
 Using switches at field devices disconnect the field wiring from power sources before servicing.
Failure to comply with these instructions could result in death or serious injury.
16 point High Level Analog Input Wiring (Figure 49)
Be sure to set the module DIP switches for voltage or current mode. See page 87. This requires Low
Voltage Euro style 36-terminal terminal block.
Note: Unused input channel shall not be left open for 900A16-0102 IO module
  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives
  • ABB MNS iS motor control center
  • ABB Condition MonitoringMService