K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB 07AC91D 07AC91 Analog input/output unit
❤ Add to collection

ABB 07AC91D 07AC91 Analog input/output unit

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

Die kleine aber leistungsfähige

Verarbeitungsstation

Der Advant Controller 70 ist eine kleine aber

leistungsfähige, vom Anwender konfigurier bare Verarbeitungsstation.

23000.00
¥23000.00
Weight:3.550KG
Quantity:
(Inventory: 23)
Consultation
Accessories
  • FOXBORO-FBM232 F
    Original :¥10238.00
    With a price :¥10238
    Quantity  
  • YOKOGAWA-AFV30D-
    Original :¥70897.00
    With a price :¥70897
    Quantity  
  •   
    Original :¥
    0.00
      
      With the total price :¥
    0.00
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

Die kleine aber leistungsfähige

Verarbeitungsstation

Der Advant Controller 70 ist eine kleine aber

leistungsfähige, vom Anwender konfigurier bare Verarbeitungsstation.




ABB 07AC91D 07AC91 Analog input/output unit

Die kleine aber leistungsfähige
Verarbeitungsstation
Der Advant Controller 70 ist eine kleine aber
leistungsfähige, vom Anwender konfigurier bare Verarbeitungsstation.
Er kann entweder einzeln als autonome
Verarbeitungsstation oder als Bestandteil eines
Advant OCS Prozessleitsystems eingesetzt
werden. Er kann mit unter Windows laufen den Überwachungsstationen kommunizieren
und sowohl analoge als auch binäre Signale
verarbeiten. Deshalb bietet sich der Advant
Controller 70 als ideale Lösung für Ihre leit technischen Aufgaben an, sei es zur Automati sierung einer einzelnen Maschine oder zum
Einstieg in die anlagenweite Automatisierung.
Advant Controller 70 kommunizieren unterein ander und mit anderen Verarbeitungsstationen
über den als standardisierte verdrillte Doppel leitung ausgeführten Advant Fieldbus 100. Der
Advant Controller kann im Feldbereich in der
Nähe von Sensoren und Aktoren installiert
werden, um die Verkabelungskosten und so
die Montagekosten insgesamt zu senken.
Er bietet folgende Vorteile:
• Flexibilität bei der Installation
• modularer Aufbau, der einen nahezu unbe grenzten, schrittweisen Ausbau ermöglicht
• günstiges Preis-/Leistungsverhältnis, das
Einsparungen bei Hardware, Verkabelung,
Installation und Wartung ermöglicht
• Zuverlässigkeit und Eigendiagnose, damit
die Anlage viele Jahre störungsfrei läuft
• Offenheit durch Unterstützung des OPC Standards, der es möglich macht, Advant
Controller 70 mit OPC-kompatibler Software
Ihrer Wahl zu kombinieren.
Der Advant Controller 70 hilft dem Anwender,
seine Produktivität und Wettbewerbsfähigkeit

zu steigern – und gelassen abzuwarten.

Anpassbar an jede Anlage

Der Advant Controller 70 ist modular aufgebaut und besteht aus passiven Geräteanschlusseinheiten, die nebeneinander auf
DIN-Hutprofilschienen montiert sind. Diese
Anschlusseinheiten verlängern den internen
Modulbus schrittweise und stellen Schraubklemmen für den Anschluss aller ankommenden und abgehenden Prozesskabel bereit. Auf
diese Geräteanschlusseinheiten werden die
Prozess-E /A-Module aufgesteckt, die als
Schnittstellen zur Außenwelt dienen.
Für die Prozess-E/A-Module stehen zwei Arten
von Geräteanschlusseinheiten zur Verfügung,
nämlich eine kompakte Bauform für die
senkrechte Montage der Module und eine
erweiterte Bauform für die waagerechte
Montage. Erstere ist platzsparend und erlaubt
die größtmögliche Anzahl von E/A-Kanälen
pro Hutprofilschiene, letztere stellt mehr Platz
für die Verkabelung zur Verfügung. Die
erweiterte Bauform verfügt über Sicherungen
und Klemmen zur Stromversorgung von
Feldgeräten, so dass in den meisten Fällen auf
externe Rangierverteiler verzichtet werden
kann.
Kompakte und erweiterte Geräteanschlusseinheiten können innerhalb einer Station
nebeneinander verwendet werden, d. h. sie
können beliebig gemischt und an die Anforderungen jedes einzelnen Feldgerätes angepasst
werden.
Da die Anforderungen des Advant Controller
70 hinsichtlich Platzbedarf und Schutz gegen
Umwelteinflüsse gering sind, stellt er eine
kostengünstige Lösung für die dezentrale
Vor-Ort-Installation dar.
Direkte Verbindungen zum Prozess
Binäre Prozess-E/A-Module verfügen
typischerweise über 16 Kanäle, analoge
Module über 8 Kanäle. Da ein Advant
Controller 70 maximal 12 E/A-Module aufnehmen kann, ergibt das pro Station max. 192
binäre bzw. 96 analoge Signale oder irgendeine entsprechende Kombination dieser Signale.
Mit einer zusätzlichen Modulbus-Erweiterung
können insgesamt 24 E/A-Module untergebracht werden.
Allerdings lassen sich an einen einzigen
Advant Fieldbus 100 bis zu 80 Stationen
anschließen, so daß ein aus mehreren Advant
Controller 70 aufgebautes System mehrere
Tausend E/A-Signale verarbeiten kann.
Die E/A-Module einer Station können alle auf
einer oder verteilt auf mehreren Profilschienen
montiert werden, wobei sie im letztgenannten
Fall über steckbare Kabel miteinander verbunden werden. Durch diese unterschiedlichen
Montagemöglichkeiten ist der Advant
Controller 70 für den Einbau in eine breite
Palette serienmäßiger Wandgehäuse und
Schränke geeignet.
Es stehen Ein- und Ausgabemodule für DC/
AC-Signalpegel und Geräte nach Industriestandard, einschließlich Widerstandstemperaturfühler und Thermoelemente, zur
Verfügung. Deshalb können prozessnahe
Geräte mit minimaler Signalaufbereitung an
den Advant Controller 70 angeschlossen
werden.
Grafische Programmerstellung und
offene Kommunikation
Der Advant Controller 70 wird in der
benutzerfreundlichen Programmiersprache
AMPL programmiert. Diese Programmiersprache ist eine Funktionsbausteinsprache
  • FOXBORO FDC280 RH101FQ DCS Modules
  • ABB LDGRB-01 Highly functional controller module
  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives