K-WANG
This GS covers the hardware specifications of the
Field Control Unit (FCU) which is the core of the
control function of the Field Control Station (FCS).
AFV30, AFV40, ACB51, ANB10, ANB11 and
ANT10U can also be constructed by combining the
Base Plate and each module. Refer to “FIO System
Overview” (GS 33J60A10-01EN).
YOKOGAWA-AFV30D-A41252-Duplexed Field Control Unit
STANDARD SPECIFICATIONS For the installation specifications and the environmental conditions common to the systems, refer to “Integrated Production Control System CENTUM VP System Overview” (GS 33J01A10-01EN). l Memory Protection During Power Failure Battery Battery Back-up for Main Memory: Max. 72 hours Battery Recharge Time: Min. 48 hours l READY Contact Output 2 terminals (NC, C) Contact Points open during FCU failure Contact Rating: 30 V DC, max. 0.3 A Note: When option code /HKU is specified, a FCU fault contact is output from the House Keeping Unit (HKU). l Communication Interface Vnet/IP Interface: Dual-redundant For more details, refer to "Integrated Prodction Control Systrm CENTUM VP System Overview" (GS 33J01A10-01EN) l HKU Interface (Option) When option code /HKU is specified, a FCU fault contact is output from the HKU. Also, the environmental conditions of the cabinet connected via the HK bus and optical ESB bus can be monitored and the operating status of the HKU can be displayed on the HIS. System alarms can also be displayed. l No. of Node Units Connectable Max. 13/FCU The total number of ESB Bus Node Units (ANB10) and Optical ESB Bus Node Units (ANB11) that can be connected to FCU are 13 or less. l Module Configuration Power Supply Module (PW481. PW482. or PW484): 2 modules for dual-redundant configuration. Processor Module (CP471 or CP461): 2 modules for dual-redundant configuration. A dual-redundant configuration is enabled by using 2 identical modules with same model code (CP471 or CP461). I/O Module (*1): Max. 8 *1: Non-standard component
Installation Restrictions To connect the ESB Bus Node Unit (ANB10) or Optical ESB Bus Node Unit (ANB11) to the FCU, install the ESB Bus Coupler Module (EC401 or EC402) in slots 7 and 8 of the FCU. For the dual-redundant configuration of the processor modules, EC401 or EC402 must be installed in both slot 7 and slot 8. In case ESB Bus has a single configuration, EC401 or EC402 must be installed in slot 7 and keep slot 8 empty. To install the optical ESB bus node unit and ESB bus node unit in a remote location, use the Optical ESB Bus Repeater Master Module (ANT401 or ANT411) to connect them with an optical fiber cable. To install the optical ESB bus repeater master module in the FCU, install a pair of modules in slots 1 to 6 in order from right to left according to the number of branches. In a single configuration, install the individual modules in slots 1. 3. and 5 in order from right to left. For details, see the “Optical ESB Bus Repeater Module” (GS 33J60F51-01EN/GS 33J60F52-01EN). For the limitations and precautions for installing I/O modules, see “FIO System Overview” (GS 33J60A10-01EN). l Power Supply Specify with the Suffix Code. Voltage: 100-120 V AC, Frequency: 50/60 Hz Voltage: 220-240 V AC, Frequency: 50/60 Hz Voltage: 24 V DC l Power Consumption 100-120 V AC: 200 VA 220-240 V AC: 230 VA 24 V DC: 5.5 A l Weight Approx. 7.0 kg (AFV30S) Approx. 8.0 kg (AFV30D) l Mounting 19-inch Rack Mounting: Rack mount (M5x8 screws), Insulation bush (accessory) l Connection Power Supply: M4 screw terminal connection Grounding: M4 screw terminal connection READY Contact Output: M4 screw terminal connection Network: Connect UTP cable (CAT5e or better) to Layer 2 switch.
Nominal Tolerances : Nominal tolerance is ± 0.8 mm for the dimensions of 0.5 mm or more and 120 mm or less, and the combined nominal tolerance is ± 1.5 mm. The nominal tolerance is in accordance with JEM 1459 for the dimensions over 120 mm. n SOFTWARE REQUIREMENT A software license is required for AFV30 separately. For details, refer to the GS “VP6F1700 Control Function for Field Control Station (for AFV30/ AFV40)” (GS 33J15C10-01EN) and “VP6F3100 Project I/O License” (GS 33J15A10-01EN). n REQUIREMENTS FOR USING SEM (SEQUENCE OF EVENTS MANAGER) For using SEM, the hardware requires some conditions. For details, refer to the GS “SEM Sequence of Events Manager (for FIO)” (GS 33J30D10-01EN)
Field Control Unit Description Model AFV30S Field Control Unit (for FIO, 19-inch Rack Mountable) Suffix Codes -A Standard type (for CP471) (*1) -S Standard type (for CP461) (*3) 3 Dual-redundant Vnet/IP, single power supply 4 Dual-redundant Vnet/IP, dual-redundant power supply 1 Always 1 1 100 - 120 V AC power supply (*4) 2 220 - 240 V AC power supply (*4) 4 24 V DC power supply (*4) 0 Basic type (*5) 1 With ISA Standard G3 option (*5) 5 Basic type with no explosion protection 6 With ISA Standard G3 option and no explosion protection E Basic type with explosion protection F With ISA Standard G3 option and explosion protection 1 LFS1700 Control function for field control station (for AFV30/AFV40, Vnet/IP and FIO) (*6) 2 Always 2 (R6.01 or later) Option Codes /HKU With HKU interface (*7) /ATDOC Explosion Protection Manual (*8) /MRN With Marine Standards (*2) Note: The existing AFV30S-1 for CENTUM VP R5 can be used with CENTUM VP R6.01 or later. *1: CP471 operates with CENTUM VP R6.01 or later version of Control Function for Field Control Station. Be sure to apply the software patch for supporting CP471 for CENTUM VP R6.01. R6.02. R6.03. and R6.04. CP471 can be combined with the style code S3 or later of ESB bus coupler module EC401. See GS 33J60E30-01EN. *2: Select the option code “/MRN” if AFV30S with marine standard is required. *3: Unavailable for ordering AFV30S with CP461 due to the supply ends on October 19. 2019. Existing CP461 can be replaced with CP471. Replacement from CP461 to CP471 is prohibited to perform by a user. This replacement must be done by the service engineer authorized by Yokogawa Electric Corporation. CP471 can be combined with the style code S3 or later of ESB bus coupler module EC401. See GS 33J60E30-01EN. *4: To meet the safety standards and EMC standards, the unit must be installed in a keyed metallic cabinet. *5: These suffix codes are applicable to only AFV30S-S. They are no longer available. *6: This suffix code is acceptable to only CENTUM VP R5. *7: When used in combination with ACUKT, specify this option code “/HKU.” *8: Select the option code “/ATDOC” to follow the ATEX Directive and UKEX Regulation for use in potentially explosive