K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
GE IC693MDR390 24 Volt DC Input, Relay Output, 8 Inputs/8 Outputs
❤ Add to collection

GE IC693MDR390 24 Volt DC Input, Relay Output, 8 Inputs/8 Outputs

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

The 24 volt DC Input/Relay Output module for the Series 90-30 Programmable Logic

Controller provides 8 input points with one common power input terminal, and 8

normally-open relay circuits in the same module.

8800.00
¥8500.00
Weight:3.300KG
Quantity:
(Inventory: 30)
Consultation
Accessories
  • GE-HydranM2-Tran
    Original :¥14993.00
    With a price :¥14993
    Quantity  
  •   
    Original :¥
    0.00
      
      With the total price :¥
    0.00
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

The 24 volt DC Input/Relay Output module for the Series 90-30 Programmable Logic

Controller provides 8 input points with one common power input terminal, and 8

normally-open relay circuits in the same module.


GE IC693MDL940 Relay Output, N.O., 2 Amp - 16 Point

24 Volt DC Input, Relay Output, 8 Inputs/8 Outputs
IC693MDR390
The 24 volt DC Input/Relay Output module for the Series 90-30 Programmable Logic
Controller provides 8 input points with one common power input terminal, and 8
normally-open relay circuits in the same module. The input circuits are designed to have either
positive or negative characteristics in that they sink or source current to/from the input devices
to/from the user common and are arranged as one group of 8 inputs. The relay output circuits
are arranged in two groups of four circuits each. Each group has a common power output
terminal.
Input characteristics are compatible with a wide range of user-supplied devices, such as:
pushbuttons, limit switches, and electronic proximity switches. Current through an input results
in a logic 1 in the input status table (%I). Power to operate the field devices must be supplied
by the user.
The normally-open relay circuits are used for controlling output loads provided by the user.
The output switching capacity of each output is 2 amps. The relay outputs can control a wide
range of user-supplied load devices, such as: motor starters, solenoids, and indicators. Power
for the internal relay circuits is provided by the +24 volt DC bus on the backplane. The user
must supply the AC or DC power to operate field devices. There are no fuses on this module.
LED indicators which provide the ON/OFF status of each point are located at the top of the
module. The LEDs are arranged in two horizontal rows with eight green LEDs in each row.
The top row is labeled A1 through 8 (input points 1 through 8) and the bottom row is is labeled
B1 through B8 (relay output points 1 through 8). An insert goes between the inside and outside
surface of the hinged door. The surface towards the inside of the module (when the hinged
door is closed) has circuit wiring information, and circuit identification information can be
recorded on the outside surface. The top half of the outside left edge of the insert is
color-coded blue to indicate low-voltage circuits and the bottom half of the outside left edge is
color-coded red to indicate high-voltage circuits.
This module can be installed in any I/O slot of a 5 or 10-slot baseplate in a Series 90-30 PLC
system.


Table 8-3. Specifications for IC693MDR390
Inputs
Rated Voltage 24 volts DC
Input Voltage range –30 to +32 volts DC
Inputs per Module 8 (one group of eight inputs)
Isolation 1500 volts RMS between field and logic side
500 volts RMS between inputs
Input Current 7.5 mA (typical) at rated voltage
Input Characteristics
On-State Voltage 15 to 32 volts DC
Off-State Voltage 0 to +5 volts DC
On-State Current 4 mA (minimum)
Off-State Current 1.5 mA (maximum)
On Response Time 7 ms typical
Off Response Time 7 ms typical
Outputs
Rated Voltage 24 VDC, 120/240 VAC
Operating Voltage 5 to 30 volts DC
5 to 250 volts AC, 50/60 Hz
Outputs per Module 8 (two groups of four outputs each)
Isolation 1500 volts RMS between field and logic side
500 volts RMS between groups
Maximum Load  2 amps maximum per output
4 amps maximum per common
Minimum Load 10 mA
Maximum Inrush 5 amps
On Response Time 15 ms maximum
Off Response Time 15 ms maximum
Internal Power Consumption 80 mA (all I/O on) from +5V backplane bus
70 mA (all outputs on) from relay +24V backplane bus
Maximum load current is dependent on operating voltage as shown in the following table.
Refer to Appendix B for product standards and general specifications.
Table 8-4. Load Current Limitations for IC693MDR390
Operating Maximum Current for Load Type Typical Operations
Voltage Resistive Lamp or Solenoid  (number of Operations)
240 VAC, 120 VAC, 24 VDC 2 amps .6 amps 200,000
240 VAC, 120 VAC, 24 VDC 1 amp .3 amps 400,000
240 VAC, 120 VAC, 24 VDC .5 amps .1 amp 800,000
For inductive loads
Relay contact life, when switching inductive loads, will approach resistive load contact life if
suppression circuits are used. The following figures are examples of typical suppression
circuits for AC and DC loads. The 1A, 100V diode shown in the DC load typical suppression
circuit is an industry standard 1N4934. The resistor and capacitor shown for AC load
suppression are standard components, available from most electronics distributors.
  • Yokogawa AQ6377E Optical Spectrum Analyzer Remote Control
  • Yokogawa AQ6361 Optical Spectrum Analyzer
  • Yokogawa IS8000 Integrated Software ECU Monitoring and Synchronization Function
  • Yokogawa ROTAMASS TI Coriolis Mass Flow Meter
  • Yokogawa ROTOMETER RAMC Metal Variable Area Flow Meter
  • Yokogawa SL1000 high-speed data acquisition unit input module
  • ​Yokogawa FLXA402T turbidity and chlorine liquid analyzer Installation and wiring
  • Yokogawa WTB10-DO Series Dissolved Oxygen Measurement System Terminal Box
  • Yokogawa Model 702928 PBD0200 Differential Probe
  • YOKOGAWA ADMAG TI Series AXW Electromagnetic Flow Meter (25-450mm) Installation and Operation
  • YOKOGAWA ADMAG TI series AXW electromagnetic flowmeter (25-1800mm)
  • YOKOGAWA DO30G Dissolved Oxygen Sensor
  • YOKOGAWA SC4AJ Conductivity Sensor
  • YOKOGAWA SC210G Conductivity Detector
  • Yokogawa PH4/OR4 series pH and ORP sensor (IM12B10B00-01EN)
  • Yokogawa OR8EFG KCl filled ORP sensor (IM12C07J01-01E)
  • YOKOGAWA FU24 pH/ORP Composite Sensor with Pressure Compensation (IM 12B06J03-03EN-P)
  • Yokogawa SC200 Intelligent Two Wire Conductivity Transmitter System (IM12D08B01-01E)
  • YOKOGAWA CENTUM VP Integrated Production Control System (TI33J01A10-01EN)
  • ABB AO2000-LS25 Laser Analysts User Manual
  • YOKOGAWA FA-M3 positioning module (with analog voltage output)
  • YOKOGAWA FA-M3 Series Basic Modules
  • YOKOGAWA EJA110E Diff erential Pressure Transmitter
  • Zygo 3D Optical Profiler
  • Zygo Mark II 4-inch interferometer system
  • Zygo NewView 9000 3D Optical Contour Analyzer Core Features
  • Zygo NewView 9000 3D Optical Profilometer Technology
  • Zygo Profilometer Standard Operating Procedure
  • Zygo’s Guide to Typical Interferometer Setups
  • ZYGO Laser Interferometer Accessory Guide OMP-0463AM
  • ZYGO MetroPro 9.0 Reference Guide (OMP-0347M)
  • Zygo Device Standard Operating Procedure (SOP)
  • Zygo Verify Laser Interferometer
  • Zygo MicroLUPI interferometer
  • ZYGO ZMI-1000 Displacement Measuring Interferometer System
  • Zygo's ZMI 2000 displacement measurement interferometer system
  • ABB IGCT Technology: A Revolutionary Breakthrough in High Voltage Inverters
  • Siemens 6AG1204-2BB10-4AA3 Ethernet Switch
  • Siemens 6ES7193-4JA00-0AA0 Terminal Module
  • Siemens ET200SP 6ES7193-6PA00-0AA0 server module
  • Siemens 6ES7231-0HC22-0XA0 Analog Input Expansion Module
  • Siemens 6ES7350-2AH01-0AE0 Counter Module
  • Siemens 6ES7421-7DH00-0AB0 Digital Input Module
  • Siemens 6AV2124-2DC01-0AX0 Comfort Panel
  • Siemens 6ES7193-4CA40-0AA0 ET 200S Electronic Module
  • STOBER POSIDRIVE ® MDS 5000 installation method
  • Siemens 7XV5653-0BA00 dual channel binary signal transmitter
  • Bently Nevada 3500/65 145988-02 Channel Temperature Monitor
  • Thinklogical Velocity KVM-34 series KVM fiber extender
  • Watlow MLS300 Series Controller
  • ​DHR NLS3000 NLC System (Navigation Control System)
  • Watlow Anafaze CLS200 Series Controller
  • CyberPower UT650EG / UT850EG User’s Manual
  • Thermal Solutions EVS series gas regulated boilers
  • Bosch Rexroth HM20 Hydraulic Pressure Sensor
  • ABB SPAU 341 C Voltage Regulator
  • Rockwell Automation 1585 Ethernet Media
  • Rockwell Automation SmartGuard 600 Controller
  • Rockwell Automation 1756 ControlLogix Communication Module
  • Rockwell Automation Stratix series Ethernet devices
  • A-B Ultra3000 and Ultra5000 with DeviceNet
  • ABB INNIS21 Network Interface Slave module
  • DEIF RMV-111D undervoltage and overvoltage relay
  • SAUTER AVM 234S valve actuator (with positioner)
  • REXRTOH INDRAMAT TVD 1.3 power module
  • Honeywell Expert Series-C I/O Module
  • ​GE PACSystems RX7i power module (IC698PSA100/350 series)
  • Yokogawa AFV40S/AFV40D Field Control Unit (FCU)
  • Schneider 31H2S207 FBM207/b/c Voltage Monitor/Contact Sense Input Modules
  • Emerson S Series Traditional I/O Modules
  • MKS Type T3B Butterfly Valve (with DeviceNet Interface)
  • Triconex 3624 Digital Output Module
  • ABB 3BSE031151R1 PM865K01 Processor Unit HI
  • GE V7768 VME Single Board Computer
  • HIMatrix F30 01 Safety-Related Controller
  • Welker Bearing Linear Guides and Wedge Components
  • GE Multilin MIF series digital feeder relay
  • ABB MNS iS MConnect interface
  • Emerson PR6426 32mm Eddy Current Sensor
  • Schneider ELAU PacDrive C400/C400 A8 Controller
  • Yokogawa Motor YS1700 Programmable Indicator Controller
  • Honeywell Searchline Excel Infrared Open Circuit Gas Detector
  • Rockwell Automation ICS AADvance Controller
  • ABB Relion ® 615 series RED615 line differential protection and control device
  • DEIF PPU-3 Parallel and Protection Unit
  • Foxboro PBCO-D8-009 Terminal Board (TB)
  • ASEM HT2150/QT2150 Fanless Panel Control Computer (IPC)
  • ABB FOUNDATION ™ Fieldbus Link Device LD 810HSE Ex V1.0
  • ABB Panel 800 Version 6 PP885 Hardware and Installation
  • Konica Minolta CM-3700A-U Plus spectrophotometer
  • Schneider FBM233 Field Device System Integrator Module
  • MTL 8502-BI-DP Bus Interface Module (BIM)
  • ABB DO880 Ability ™ System 800xA ® hardware selector
  • GE VMIVME-2540 24 channel intelligent counter/controller
  • GE VMIVME-3115-010 32-Channel 12-bit Analog Output Board
  • GE Fanuc Automation VMIVME-4140 32-Channel 12-bit Analog Output Board
  • BENTLY 1900/65A General Purpose Equipment Monitor
  • REXROTH Digital axis control HNC100
  • GE Grid Solutions 369 Series
  • ZYGO ZMI 7702 laser head
  • ZYGO ZMI 501A shell
  • ABB PFEA111-65 Tension Electronic Equipment
  • Allen Bradley 1753 Series GuardPLC 1800 Controller
  • Allen Bradley 1753 Series GuardPLC 1800 Controller
  • Allen Bradley 1747-DCM Direct Communication Module
  • Allen Bradley 1746-NI8 SLC 500 Analog Input Module
  • Allen Bradley 1734 series POINT I/O common terminal module and voltage terminal module
  • Allen Bradley 150 Series SMC Dialog Plus Controller
  • Allen Bradley 1494V series
  • AB Allen Bradley 1492 series terminal block
  • Allen Bradley 1485 Series DeviceNet Media System
  • Allen Bradley 1391-DES series digital AC servo drive
  • Allen Bradley 1336 PLUS II Adjustable Frequency Driver
  • Allen Bradley 1336 IMPACT AC Inverter
  • Allen Bradley 1326AB high-performance AC servo motor
  • Allen Bradley DeviceNet Communication Module (1203-GK5/1336-GM5)
  • Allen Bradley 1203-CN1 ControlNet Communication Module
  • Rockwell Automation PanelView Standard Series Terminal (Model 2711)
  • Siemens SIMATIC S7-300 6ES7322-1BH01-0AA0 Digital Output Module
  • Siemens SIMATIC S7-300 Digital Input Module (6ES7321-1BH02-0AA0)
  • Rockwell Automation 836T Series Differential Pressure Controller
  • Schneider Modicon Quantum 140DRA84000 Discrete Output Module
  • Schneider Modicon Quantum 140CPS11420 power module
  • Schneider Modicon Quantum 140ACO02000 Analog Output Module
  • Schneider Modicon Quantum 140CPU65260 Unity Processor
  • SIEMENS 6GK1105-2AA10 SIMATIC NET series optical switching module (OSM ITP62)
  • Modicon Quantum 140XBP01000 racks backplanes
  • ABB NTST01 Time Sync Link TU Time Sync Link Terminal Unit