K-WANG
ABB 1SBP260052R1001 ICMK14N1 Advant Controller 31 Remote Unit
Basic Information.
Product Overview:ABB 1SBP260052R1001 ICMK14N1 is a remote unit in the Advant Controller 31 system. It plays a key role in industrial automation control systems, mainly used for data acquisition and device control at a location away from the main controller, effectively extending the control range and functions of the system.
Physical Characteristics: The remote unit is usually of compact modular design and is conveniently mounted on a mounting bracket near the control cabinet or field equipment. Its enclosure is generally made of robust materials, such as metal or high-quality engineering plastics, with good electromagnetic compatibility (EMC) and mechanical protection against electromagnetic interference, dust, moisture and a certain degree of physical shock in the industrial environment.
Functional features
Input and output functions
Digital Input (DI): With multiple digital input channels, it is used to receive digital signals from external devices, such as signals generated by switches, pushbuttons, proximity switches, limit switches and other devices. These signals can be used to monitor changes in the state of the device, such as the start/stop state of the device, position status, etc. The input channels usually support different voltage levels, such as 24V DC and other common industrial control voltages, and have a certain signal filtering function to improve the signal's anti-interference ability.
Digital Output (DO): Equipped with digital output channels, it can output digital signals to control external devices, such as relays, solenoid valves, indicator lights, etc. The output signals can drive these devices to perform the corresponding functions. The output signals can drive these devices to perform corresponding actions, such as controlling the opening and closing of solenoid valves to control the flow of fluids, or controlling the lighting of indicator lights to show the working status of the equipment. The output current and voltage of the output channel can meet the driving requirements of industrial equipment within a certain range.
Analogue Input (AI): with analogue input channels for collecting signals from various analogue sensors, such as temperature sensors, pressure sensors, flow sensors and other standard analogue signals such as 0 - 10V DC, 4 - 20mA. These channels can convert analogue signals into digital signals with high precision for system processing, and the signal resolution is usually high to accurately reflect changes in physical quantities on site.
Analogue Output (AO): It also has analogue output channels, which are used to output analogue signals to control devices that require continuous adjustment, such as frequency converters to control motor speed, regulating valves to control the flow rate, etc. The range and accuracy of the output signals can meet the requirements of the system. The range and accuracy of the output signals can meet the requirements of industrial process control and ensure precise control of the equipment.
Communication function
Communication interface support: Equipped with a variety of communication interfaces, such as Ethernet interface (RJ45), serial interface (RS-232, RS-485) and so on. These interfaces enable the remote unit to communicate with the main controller (Advant Controller 31) and other devices. The Ethernet interface supports high-speed data transmission and is suitable for long-distance and large-data-volume communication scenarios, such as communication with the central control system in large factory network environments; the serial interface can be used for communication in close proximity or specific devices, and has a certain degree of anti-interference ability.
Communication protocol compatibility: Supports a variety of industrial communication protocols, such as Modbus, Profibus, TCP/IP and so on. Through these protocols, it is able to communicate with equipment and control systems of different manufacturers in a compatible way to achieve data sharing and interaction. For example, in a factory containing many kinds of automation equipment, it is possible to communicate with PLCs, sensors, actuators and other equipment of other brands to build a complete automation control system.
Diagnostic and Protection Functions
Self-diagnostic function: It has self-diagnostic capability and can monitor its own working status in real time. It can detect the working status of each input and output channel, the connection of the communication link, and whether the power supply is normal. When a fault occurs, it can generate a fault code through the internal diagnostic mechanism or indicate the fault information through the status indicator, which is convenient for maintenance personnel to quickly locate and solve the problem.
Protection mechanism: In order to protect itself and the connected external equipment, a variety of protection measures are set. For example, over-voltage protection and over-current protection are provided on the input and output channels. When the input signal voltage is too high or the output current exceeds the rated value, it can automatically cut off the channel or take other protective measures to prevent equipment damage.
Technical Parameters
Electrical parameters
Operating voltage range: Generally has a wide operating voltage range, such as 18 - 30V DC or 85 - 264V AC, in order to adapt to different power supply environment. Within this voltage range, the remote unit can work stably and has certain anti-interference ability to power fluctuation.
Input/Output Electrical Characteristics: The input voltage range of the digital input channels may vary depending on the specific configuration, e.g., the input voltage range of the 24V DC input channel is generally 18 - 30V DC, and the input current is usually between a few milliamps and tens of milliamps. Digital output channels typically have output current ratings between 0.5 - 2A, and output voltages can be of various levels depending on load and configuration. The analogue input channels are capable of handling common analogue signal ranges such as 0 - 10V DC, 4 - 20mA, and may have signal resolutions of 12 - 16 bits. The analogue output channels have similar output signal ranges and resolutions to meet the requirements of precise control.