K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB-TZID-C-V18345-Electro-Pneumatic Positioner
❤ Add to collection

ABB-TZID-C-V18345-Electro-Pneumatic Positioner

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

The TZIDC is an electronically configurable positioner with  communication capabilities designed for mounting to pneumatic  linear or rotary actuators. It features a small and compact design, a  modular construction, and an excellent cost-performance ratio.  Fully automatic determination of the control parameters and  adaptation to the final control element yield considerable time savings  and an optimal control behavior

21832.00
¥19384.00
Weight:5.300KG
Quantity:
(Inventory: 22)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

The TZIDC is an electronically configurable positioner with  communication capabilities designed for mounting to pneumatic  linear or rotary actuators. It features a small and compact design, a  modular construction, and an excellent cost-performance ratio.  Fully automatic determination of the control parameters and  adaptation to the final control element yield considerable time savings  and an optimal control behavior


ABB-TZID-C-V18345-Electro-Pneumatic Positioner

1 Description Pos: 3.2 /==== Wechsel ein- auf zweispaltig ==== @ 0mod_1130421847171_3101.doc @ 3828  Wechsel ein-auf zweispaltig Pos: 3.3 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/Allgemein/Kurzbeschreibung/Kurzbeschreibung @ 10mod_1173180169769_3101.doc @ 71118  The TZIDC is an electronically configurable positioner with  communication capabilities designed for mounting to pneumatic  linear or rotary actuators. It features a small and compact design, a  modular construction, and an excellent cost-performance ratio.  Fully automatic determination of the control parameters and  adaptation to the final control element yield considerable time savings  and an optimal control behavior.  Pos: 3.4 /Überschriften/1.1/2-spaltig/Pneumatik @ 10mod_1176211138453_3101.doc @ 76683  1.1 Pneumatics Pos: 3.5 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/Allgemein/Kurzbeschreibung/Pneumatik @ 10mod_1173180645393_3101.doc @ 71139 a  An I/P module with subsequent pneumatic amplifier is used to control  the pneumatic actuator. The well-proven I/P module proportionally  converts the permanent electrical positioning signal from the CPU  into a pneumatic signal used to adjust a 3/3-way valve.  The air flow for pressurizing or depressurizing the actuator is  continuously adjusted. As a result, excellent control is achieved.  When reaching the set point, the 3/3-way valve is closed in center  position to minimize the air consumption.  Four different pneumatics versions are available: for single-acting or  double-acting actuators, each with “fail-safe” or “fail-freeze” function.  Pos: 3.6 /Überschriften/1.1.1/2-spaltig/Sicherheitsfunktion "entlüftend" @ 10mod_1176211744343_3101.doc @ 76809  1.1.1 “Fail-safe” function  Pos: 3.7 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/Allgemein/Kurzbeschreibung/Sicherheitsfunktion "entlüftend" @ 10mod_1176211673796_3101.doc @ 76788  If the electrical power supply fails, the positioner output 1 is  depressurized, and the pneumatic actuator’s return spring moves the  valve to the defined safe position. In case of a double-acting actuator  the second output 2 is additionally pressurized.  Pos: 3.8 /======= Spaltenumbruch ======== @ 0mod_1132937966324_3101.doc @ 3831  Pos: 3.9 /Überschriften/1.1.1/2-spaltig/Sicherheitsfunktion "blockierend" @ 10mod_1176211798765_3101.doc @ 76830  1.1.2 “Fail-freeze” function  Pos: 3.10 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/Allgemein/Kurzbeschreibung/Sicherheitsfunktion "blockierend" @ 10mod_1176211845484_3101.doc @ 76851  If the electrical power supply should fail, the positioner output 1 (and  2. if applicable) is closed and the pneumatic actuator stops  (“freezes”) the valve in the current position. If compressed air supply  should fail, the positioner depressurizes the actuator.  Pos: 3.11 /Überschriften/1.1/2-spaltig/Bedienung @ 10mod_1176211172234_3101.doc @ 76704  1.2 Operation Pos: 3.12 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/Allgemein/Kurzbeschreibung/Bedienung (Kommunikationsmöglichkeit) @ 10mod_1173184631054_3101.doc @ 71160  The positioner has a built-in operating panel providing a 2-line LCD  and 4 pushbuttons for optimal local configuration, commissioning and  operational monitoring.  Alternatively, the appropriate configuration program and the available  communication option can be used.  Pos: 3.13 /Überschriften/1.1/2-spaltig/Kommunikation @ 10mod_1176211201546_3101.doc @ 76725  1.3 Communication Pos: 3.14 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/TZIDC / TZIDC-200/Kurzbeschreibung/Kommunikation @ 10mod_1176212225390_3101.doc @ 76893  The standard TZIDC model has a local communication interface (LKS  connector). Additionally, a “HART communication” option for  communication via the 20 mA signal is available. Both  communications are based on the HART Protocol.  Pos: 3.15 /Überschriften/1.1/2-spaltig/Ein-/Ausgänge @ 10mod_1176211233015_3101.doc @ 76746  1.4 Inputs and outputs Pos: 3.16 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/TZIDC / TZIDC-200/Kurzbeschreibung/Ein-/Ausgänge @ 10mod_1176212290390_3101.doc @ 76914  In addition to its input for the analog position set point the TZIDC  positioner is equipped with a digital input which can be used to  activate various protective functions in the device via the process  control system. A digital output allows you to output collective alarms  or fault messages.  Pos: 3.17 /Überschriften/1.1/2-spaltig/Modularer Aufbau @ 10mod_1176211317984_3101.doc @ 76767  1.5 Modular design Pos: 3.18 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/Allgemein/Kurzbeschreibung/ModularerAufbau @ 10mod_1173184783043_3101.doc @ 71181 q  The TZIDC basic model can be enhanced at any time by retrofitting  optional equipment. Option modules for analog or digital position  feedback or a shutdown-module can be installed. Additionally, a  mechanical position indicator, proximity switches or 24 V  microswitches are available for indicating the position independently  of the mother board function

Low operating cost  Compact design  Well-proven technology  Robust and environmentally ruggedized  Wide operating temperature range   -40 ... 85 °C (-40 ... 185 °F)  Easy to commission, “single pushbutton”  operating philosophy  Mechanical position indicator  ATEX, FM, CSA, GOST and IECEx approvals  For SIL2 safety loops

3.1.4 Diagnosis parameters  Pos: 7.13 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/Allgemein/Betrieb/Diagnoseparameter @ 10mod_1176214500906_3101.doc @ 77406  The diagnosis parameters of the TZIDC program inform the operator  about the operating conditions of the valve.  From this information the operator can derive which maintenance  works are required, and when.  Additionally, limit values can be defined for these parameters. When  they are exceeded, an alarm is reported.  The following values are e.g. determined:  - Number of movements performed by the valve  - Total travel  The diagnosis parameters and limit values can be called up, set, and  reset via HART communication, using the configuration program.  Pos: 7.14 /Überschriften/1.1/2-spaltig/Bedienpanel @ 10mod_1176214143953_3101.doc @ 77229  3.2 Operator panel Pos: 7.15 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/Allgemein/Betrieb/Bedienpanel TZIDC-1x0 @ 10mod_1176214815500_3101.doc @ 77427  The TZIDC positioner’s operator panel with four pushbuttons allows  for  - operational monitoring  - manual control  - configuration  - fully automatic commissioning  The operator panel is protected by a cover which avoids  unauthorized access to the operating elements.  Pos: 7.16 /======= Spaltenumbruch ======== @ 0mod_1132937966324_3101.doc @ 3831  Pos: 7.17 /Überschriften/1.1.1/2-spaltig/Ein-Tasten-Inbetriebnahme @ 10mod_1176214193156_3101.doc @ 77250  3.2.1 Single-button commissioning  Pos: 7.18 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/TZIDC / TZIDC-200/Betrieb/Ein-Tasten-Inbetriebnahme @ 10mod_1176214842843_3101.doc @ 77448  Commissioning the TZIDC positioner is especially easy. The  standard Autoadjust function for automatic adaptation of the device  parameters can be started by simply pressing a single front panel  button, and without knowing parameterization details.  Depending on the selected actuator type (linear or rotary), the  displayed zero position is automatically adapted:  - for linear actuators counter-clockwise (CTCLOCKW)  - for rotary actuators clockwise (CLOCKW).  Besides this standard function, a customized “Autoadjust” function is  available. The function is launched either via the operator’s panel or  HART communication.  Pos: 7.19 /Überschriften/1.1.1/2-spaltig/Anzeigen @ 10mod_1176214259859_3101.doc @ 77271  3.2.2 Display  Pos: 7.20 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/TZIDC / TZIDC-200/Betrieb/Anzeigen @ 10mod_1176214873937_3101.doc @ 77469  The information indicated by the 2-line LC display is permanently  updated and adapted during operation, to inform the operator in an  optimal way.  During control operation (control with or without adaptation) the  following TZIDC data can be called up by pressing the pushbuttons  briefly:  - Up button: Current setpoint (mA)  - Down button: Temperature in device  - Up + Down buttons: Current control deviation  Pos: 7.21 /==== Wechsel zwei- auf einspaltig ==== @ 0mod_1130421955859_3101.doc @ 3829  Wechsel ein-auf zweispaltig

  • IbaPADU-S-IT-16 modular central unit
  • YASKAWA ∑ - II Series SGMBH/SGDH AC Servo System
  • ibaBM-CAN CAN / CANopen Bus Sniffer
  • IbaLink-SM-128V-i-2O VMEbus interface board
  • GE Fanuc 90-30 PLC Hardware Guide
  • Automation Direct GS2 Drives Tech Guide
  • Comprehensive Technical Guide for OMRON 3G3MV Inverter
  • Danfoss VACON NXI Inverter FI9-FI14 Operation Guide
  • Saia PCD4.U100 System Migration Complete Guide
  • Yaskawa NS300 DeviceNet Module Guide
  • OMRON SYSMAC C-series PLC Programming Guide
  • Kollmorgen ServoStar S Drive Installation and Debugging Guide
  • Omron C200HX/HG/HE PLC Installation and Configuration Guide
  • SIEMENS SINAMICS S120 Driver
  • Emerson ControlWave® Micro Hybrid Controller
  • ABB 800xA for Advant Master Configuration
  • OMRON FQM1 Motion Controller Instruction System
  • Schneider Easergy P5 Communication Architecture and Protocol
  • ABB JOKAB SAFETY Pluto series safety PLC
  • Lenze L-force series HMI EL 100 series human-machine interface
  • Pilz PSEN opII4H series safety light curtain operation instructions
  • Danfoss VACON ® NXP and VACON ® NXC series AC frequency converter
  • EATON Crane Control System Complete Guide
  • ProSoft MVI56-PDPMV1 Module: PROFIBUS DPV1 Master Integration Complete Guide
  • DEIF XDi series FLEXIBLE DISPLAY INDICATORS
  • DEIF AGC 100 series generator set controller
  • DEIF AGC-3 Automatic Generator Set Controller
  • DEIF Multi line 2/version 2-GS Multi functional Generator Protection and Control Unit
  • KONGSBERG AIS BS600 shipborne automatic identification system base station
  • KONGSBERG HMS 300 Helicopter Deck Monitoring System
  • Honeywell HPM Series Particulate Matter Sensors
  • HONEYWELL Expert C300 Controller
  • HONEYWELL HCiX series touch panel operation interface
  • Honeywell T901Px1A Inert Gas Pressure & Temperature Transmitter for Liquid Cargo
  • HONEYWELL Expert Series-C I/O Module
  • HONEYWELL INTELLIKNIGHT®MODEL 5700 Addressable Fire Alarm Control Panel
  • HONEYWELL Expert PKS C300 Controller
  • HONEYWELL Experion Local Control Network   
  • HONEYWELL IRIS P522 Signal Processor Flame Monitoring Equipment
  • HONEYWELL EC7830A, RM7830A, EC7850A, RM7850A 7800 SERIES Relay Modules
  • HONEYWELL Sensepoint XCD Flammable, toxic and oxygen gas detector for industrial applications 
  • HONEYWELL Sensepoint XCD gas detector
  • HONEYWELL Series 61 and Series 62 Modutrol IV™ Motors
  • HONEYWELL M6161, M6181, M6184, M6191, M6194 models Modutrol IV ™ motor
  • Kongsberg C-series Cutting System: Operation, Maintenance, and Tool Technical Guide
  • KONGSBERG DPS i2 is a sensor fusion GNSS solution designed specifically for dynamic positioning (DP)
  • KONGSBERG DPS 114 Durable and Reliable DGNSS (DGPS/DGGLONASS) Sensor
  • KONGSBERG DZ-110/U transmitter safety barrier unit
  • KONGSBERG DZ-120 Zener Safety Barrier Unit
  • KONGSBERG MST 319/324/342 series mini SSBL responder
  • BridgeMaster E 180 and 250 EPA (L) Series of Marine Radars
  • KONGSBERG K-Chief 600 Control Room Panel (CRP) for Ship Automation System
  • KONGSBERG K-MASTER BRIDGE SOLUTIONS
  • Maintenance Manual Kongsberg Steering Gear type SR and SV
  • KONGSBERG RMP420 Remote Multi functional I/O Module
  • KONGSBERG's RMP420 Remote Multifunctional I/O Module
  • Kongsberg WCU Watch Cabin Unit - LED version
  • KONGSBERG K-Nav Navigation Product Series
  • KONGSBERG K-Chief Ship Automation System
  • KONGSBERG RCU 500 Remote Controller
  • Kongsberg Maritime AS Distributed Processing Units Engine Safety Unit (ESU)
  • KUKA KR C5 Robot Controller
  • KUKA KR C4 compact robot controller
  • KUKA KR C2 edition2005 Robot Controller Operation Manual
  • Eaton A200/A210/A250 Specification 5 Motor Controller Operating Manual
  • Eaton MICRO PANEL XV-152 Industrial Tablet Operating Manual
  • Eaton B-Line Series Product Portfolio
  • EATON Time delay undervoltage module
  • Eaton 5P series UPS products
  • Cooper Crouse Hinds EVLS HAZARD-GARD Explosion proof Lamp Installation and Maintenance
  • Eaton EX series UPS products
  • Durant Ambassador Series 5760X-405 Counting Controller Operating Instructions
  • Eaton xEnergy Safety Ci Insulated Distribution Enclosure
  • EATON MICRO PANEL XP-702 Operating Manual
  • EATON SPD series surge protector
  • EATON MVX9000 series sensorless vector frequency converter
  • EATON EasyE4 Nano Compact Programmable Logic Controller
  • EATON Cutler Hammer FP-4000 Medium Voltage Feedline Protection Relay
  • EATON FP-4000 feeder protection relay
  • EATON XT series stabilizing pump control box
  • EATON MP-4000 motor protection relay
  • EATON ELPRO 245U-E series industrial wireless Ethernet products
  • EATON MTL4850 HART multiplexer operating instructions
  • EATON Ambassador series (models 5760X-405, etc.) counting controller
  • EATON Crouse Hinds series of harsh/hazardous environment LED lighting products
  • EATON 9000X AF series (SVX9000/SPX9000) frequency converter
  • EATON S801+series soft starter
  • EATON XV-303/XV-313 series multi touch display
  • EATON XV200 Mini Panel Operation Instructions
  • EATON CG Controller
  • EATON KD, HKD, KDC, CKD, CHKD K-frame molded case circuit breakers
  • EATON Series C Plastic Case Circuit Breaker and Motor Circuit Protector
  • EATON MP-3000 Advanced Motor Protection Relay
  • EATON XV-303/XV-313 series industrial multi touch HMI display
  • EATON Series 8/9 (VISA8/VISA9) vacuum arc extinguishing chamber
  • EATON FP-5000 microprocessor base panel mounted multifunctional protection relay
  • EATON IQ500 modular intelligent multifunctional power meter
  • EXOR eTOP Series 300 Operating Instructions
  • UniOP MD02F-02 and MD02R-04 Compact Low Cost Industrial HMI Equipment
  • UniOP CP02F-02, CP02R-04 Compact Industrial HMI Equipment
  • UniOP CP01R-04, CP05R-04, and CP01F-02 Compact Low Cost HMI Devices
  • UniOP ECT-16 Industrial PLC Workstation Operator Interface System
  • UniOP ePALM10 Handheld Human Computer Interface
  • UniOP ePAD03/ePAD04 Human Computer Interface
  • Union Special XF500 series sewing machine
  • UniOP Universal Operation Panel Installation Guide
  • UniOP eTOP306 Human Computer Interface
  • UniOP Universal Operation Panel Installation Guide
  • Allen-Bradley SLC 500 SYSTEMS SELECTION GUIDE
  • WITTENSTEIN alpha LP+/LPB+low backlash planetary gear reducer
  • ABB AX400 Series Models AX460 and AX466 Single and Dual Input pH/Redox (ORP) Analysts
  • ALSTOM ALSPA series drives
  • ALSTOM ALSPA P1200NT Tripping and Control Relays
  • GE Vernova MVAJ 05/10/20 series is a tripping and control relay
  • GE Vernova MVAW 11/13/21 type intermediate relay
  • ALSTOM ALSPA MV1000 High Performance Low Voltage Inverter
  • GE Vernova MMLG/MMLB Test Blocks and Test Plugs
  • Baker Hughes 1900/65A General Purpose Equipment Monitor
  • DEIF LSU-112DG Load Distribution Unit
  • DEIF PPM 300 Protection and Power Management Controller
  • DEIF Delomitic-3 High Flexibility Multifunctional Generator Set Control and Protection System
  • DEIF DELOMATIC 400 GAS Modular Gas Engine Control and Monitoring System
  • Xiamen Kongjiang Automation Technology Co., Ltd – تأمین‌کننده تخصصی قطعات اتوماسیون صنعتی و سیستم‌های DCS
  • DEIF MULTI-LINE 2 Option X Additional display and operator panel
  • DELL EMC NETWORKING X-SERIES
  • Eaton MP-3000 series motor protection relay
  • Eaton TX series cam switch and PX series load isolation switch
  • Official Operating Instructions for Eaton XControl Series Modular PLCs (XC-104-.../XC-204-.../XC-303-...)