K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB SI-Unit Fuse Module POK 71 H&B Contronic
❤ Add to collection

ABB SI-Unit Fuse Module POK 71 H&B Contronic

+86-15305925923
Mr.Wang
wang@kongjiangauto.com
SI-Unit Fuse Module POK 71 H&B Contronic
6292.00
¥1097.00
Weight:2.000KG
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description
SI-Unit Fuse Module POK 71 H&B Contronic

ABB SI-Unit Fuse Module POK 71 H&B Contronic

Basic Introduction

ABB SI - Unit Fuse Module POK 71 H&B Contronic is a SI (International System of Units) unit fuse module designed by ABB for H&B Contronic systems. It plays a key role in the safety of the circuits in the system.

Functional features

Circuit Protection Functions

Overload protection: When the current in the circuit exceeds the rated current of the fuse module, the fuse will blow, thus cutting off the circuit and preventing the equipment in the circuit from being damaged by the excessive current. For example, in the event of a short circuit or abnormally high load condition in one of the devices in the system, the fuse module can respond quickly to protect other devices from damage.

Short-circuit protection: For a possible short-circuit condition in a circuit, it can quickly disconnect the circuit to prevent the short-circuit current from causing serious damage to the system. This protection mechanism is based on the fusing characteristics of the fuse. Once a short-circuit current is detected, the fuse will blow in a very short time, effectively isolating the faulty part.

System compatibility

Integrated into the H&B Contronic system: As an integral part of the H&B Contronic system, it works well with other devices and modules in the system. Its design and parameters are customized to the overall requirements of the system, ensuring that it does not negatively affect the performance of other equipment during normal system operation.

Standard Interface Connections: Usually has standard connection interfaces that make it easy to connect to the system's circuitry. These interfaces are designed to meet industry standards for ease of installation and maintenance, and to ensure the reliability and stability of the connection.

Safety and Reliability

High-quality fuse materials: High-quality fuse materials are used, which have stable blowing characteristics and ensure that they blow within the specified current and time range. For example, the material composition and manufacturing process of the fuses undergo strict quality control to ensure that they can accurately perform their protective function under different environmental conditions.

Stable performance: Under normal operating conditions, this fuse module is capable of stable operation without false blowing or performance degradation. It can withstand a certain range of temperature, humidity and voltage fluctuations, to ensure that in the complex industrial environment can still provide reliable protection for the system.

Technical Parameters

Rated current and voltage

Rated current: There are different rated current specifications available, for example, common rated current may include 1A, 2A, 5A, etc. The specific rated current value is determined according to the actual needs of the system. The rated current is the maximum current at which the fuse module can operate normally, and the fuse may blow if the current value is exceeded.

Rated Voltage: The rated voltage is also generally determined by the supply voltage of the system, which may be 24V DC, 48V DC and other common industrial voltage levels. It indicates the maximum voltage range in which the fuse module can safely operate.

Fusing Characteristics

Fusing Time - Current Curve: Has a specific Fusing Time - Current curve which describes the time it takes for the fuse to blow under different overcurrent conditions. For example, for small overcurrents, the melting time may be long, while for larger overcurrents (e.g., short-circuit currents), the melting time will be very short, usually on the order of milliseconds.

Breaking capacity: Breaking capacity is the maximum value of short-circuit current that a fuse module can safely cut off when blowing. This parameter reflects the ability of the fuse module to protect itself in the event of a short-circuit, e.g. it may have a breaking capacity of several thousand amperes, ensuring that the current can be effectively cut off in the event of a short-circuit.

Physical Parameters

Size and mounting: It is a good size for mounting in a control cabinet or on a circuit board inside the equipment. It may be mounted in standard ways, such as plug-in or screw-in, for ease of operation during system installation and maintenance.

Operating Environment Parameters: It is able to work normally in a wide range of temperature (e.g. - 10℃ - +50℃) and humidity (e.g. 10% - 90% relative humidity), adapting to different industrial environmental conditions.


  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives
  • ABB MNS iS motor control center
  • ABB Condition MonitoringMService