K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
HIMA F3501 Safety-Related Controller
❤ Add to collection

HIMA F3501 Safety-Related Controller

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

HIMatrix controllers are available for the programming tools SILworX and ELOP II Factory.  Which programming tool can be used, depends on the processor operating system of the  HIMatrix controller, refer to the following table

8588.00
¥6776.00
Weight:2.000KG
Quantity:
(Inventory: 22)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

HIMatrix controllers are available for the programming tools SILworX and ELOP II Factory.  Which programming tool can be used, depends on the processor operating system of the  HIMatrix controller, refer to the following table


HIMA F3501 Safety-Related Controller

Safety

All safety information, notes and instructions specified in this document must be strictly

observed. The product may only be used if all guidelines and safety instructions are adhered to.

This product is operated with SELV or PELV. No imminent risk results from the product itself.

The use in Ex-Zone is permitted if additional measures are taken.

2.1 Intended Use

HIMatrix components are designed for assembling safety-related controller systems.

When using the components in the HIMatrix system, comply with the following general

requirements.

2.1.1 Environmental Requirements

Requirement type Range of values 1)

Protection class Protection class III in accordance with IEC/EN 61131-2

Ambient temperature 0...+60 °C

Storage temperature -40...+85 °C

Pollution Pollution degree II in accordance with IEC/EN 61131-2

Altitude < 2000 m

Housing Standard: IP20

Supply voltage 24 VDC

1) The values specified in the technical data apply and are decisive for devices with extended

environmental requirements.

Table 3: Environmental Requirements

Exposing the HIMatrix system to environmental conditions other than those specified in this

manual can cause the HIMatrix system to malfunction.

2.1.2 ESD Protective Measures

Only personnel with knowledge of ESD protective measures may modify or extend the system

or replace devices.

Product Description

The safety-related F35 controller is a compact system in a metal housing with 24 digital inputs,

8 digital outputs, 2 counters and 8 analog inputs.

The controller is available in various model variants for SILworX and ELOP II Factory, see

Table 6.

The device is suitable for mounting in Ex-zone 2. see Chapter 4.1.6.

The device is TÜV-certified for safety-related applications up to SIL 3 (IEC 61508. IEC 61511

and IEC 62061), Cat. 4 and PL e (EN ISO 13849-1) and SIL 4 (EN 50126. EN 50128 and

EN 50129).

Further safety standards, application standards and test standards are specified in the

certificates available on the HIMA website.

3.1 Safety Function

The controller is equipped with safety-related digital inputs and outputs, safety-related counters

and safety-related analog inputs.

3.1.1 Safety-Related Digital Inputs

The controller is equipped with 24 digital inputs. The state (HIGH, LOW) of each input is

signaled by an individual LED.

i The LEDs for the digital inputs are activated by the program if the F35 is in RUN.

The input signals are captured analogically and made available as INT values from 0...3000

(0...30 V) to the program.

i The digital inputs must not be used as safety-related analog inputs!

Configurable thresholds are used to generate BOOL values.

The default setting is:

Low level: < 7 V High level: > 13 V

The thresholds are set using system parameters, see Table 43 and Table 44. A difference of at

least 2 V must be maintained between the thresholds.

Mechanical contacts without own power supply or signal power source can be connected to the

inputs. Potential-free mechanical contacts without own power supply are fed via an internal

short-circuit-proof 24 V power source (LS+). Each of them supply a group of 8 mechanical

contacts. Figure 1 shows how the connection is performed.

With signal voltage sources, the corresponding ground must be connected to the input (L-), see

Figure 1.

Figure 1: Connections to Safety-Related Digital Inputs

For the external wiring and the connection of sensors, apply the de-energized-to-trip principle.

Thus, if a fault occurs, the input signals adopt a de-energized, safe state (low level).

An external wire is not monitored, however, an open-circuit is considered as safe low level.

3.1.1.1 Reaction in the Event of a Fault

If the device detects a fault on a digital input, the user program processes a low level in

accordance with the de-energized to trip principle.

The device activates the FAULT LED.

In addition to the channel signal value, the user program must also consider the corresponding

error code.

The error code allows the user to configure additional fault reactions in the user program.

3.1.1.2 Line Control

The detection of short-circuits and open circuits cannot be configured for the F35 system, e.g.,

on EMERGENCY STOP inputs complying with Cat. 4 and PL e in accordance with EN

ISO 13849-1.

Line monitoring for digital outputs is possible, see Chapter 3.1.4.1.


  • ADLINK NuPRO-E72 PICMG 1.3 Full length Industrial SHB Single Board Computer
  • ADLINK MXE-5400 series fanless embedded industrial computer
  • ADLINK M-322 Industrial ATX Motherboard
  • ADLINK IMB-M43H Industrial ATX Motherboard
  • ADLINK IMB-M42H Industrial ATX Motherboard
  • ADLINK i915GV-INA ATX motherboard
  • ADLINK ETX-NR667 Embedded ETX Standard Computer Module
  • ADLINK ETX-BT (PATA to SATA version) User Manual
  • ADLINK CM1-BT1 PC/104 Single Board Computer
  • ADLINK cPCI-8217 [R] 3U CompactPCI VGA/LCD Display Module
  • ADLINK AmITX-SL-G Mini ITX Embedded Motherboard
  • ADLINK AmITX-AL-I ultra-thin Mini ITX industrial motherboard
  • ADLINK NuPRO-E315 Full length PICMG 1.3 Industrial SHB Single Board Computer
  • ADLINK NuPRO-842 Full length PICMG 1.0 PCI/ISA Industrial Single Board Computer
  • ADLINK NuPRO-900A PICMG 1.2 ePCI-X Dual Xeon Industrial System Motherboard (SHB)
  • ADLINK cPCI-6910 series 6U CompactPCI single board computer
  • ADLINK cPCI-6860A 6U CompactPCI dual core single board computer with cPCI-R6860A rear adapter board
  • ADLINK cPCI-8168 6U CompactPCI Eight Axis Motion Control Card
  • ADLINK NuPRO-E340 PICMG 1.3 Industrial SHB motherboard
  • ADLINK NuPRO-A40H Full length PICMG1.0 Industrial Single Board Computer (SBC)
  • ADLINK NuPRO-852 Full length PICMG1.0 Industrial Single Board Computer
  • ADLINK NuPRO-841 Full length Industrial SBC
  • ADLINK NuPRO-590/591/592 series Socket7 full-length industrial SBC
  • ADLINK MXE-5500 series fanless embedded industrial computer
  • ADLINK MXE-200/200i Fanless Embedded Machine
  • ADLINK cPCI-6770 series CompactPCI CPU board
  • ADLINK NuPRO-A301 standard PICMG 1.0 full-length industrial SBC single board computer
  • ADLINK NuPRO-965 PICMG 1.3 SHB Express Full length Industrial Motherboard
  • ADLINK NuPRO-935A Full length PICMG1.0 Industrial Single Board Computer
  • ADLINK NuPRO-865 Full length Single Board Computer
  • ADLINK NuPRO-840 DV/LV Full Length PICMG Industrial Single Board Computer
  • ADLINK NuPRO-770 series full-length industrial single board computer
  • ADLINK NuPRO-595 series half length Socket 7 industrial motherboard
  • ADLINK cPCI-6840 series 6U CompactPCI single board computer
  • Foxboro 43AP series pneumatic indicator controller (PSS 3-1B3 A)
  • ADLINK cPCI-3720 Series 3U Low Power CompactPCI Single Board Computer
  • ADLINK NuPRO-E47, PICMG 1.3 full-length industrial SHB system motherboard
  • ADLINK NuPRO-E43 PICMG 1.3 full-length system motherboard
  • ADLINK NuPRO-780 series full-length industrial CPU board
  • ADLINK cPCI-6965 series 6U CPCI single board computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB interface card
  • Rittal SK 3241.700 Blue e+Fan Filter Unit
  • ADLINK cPCI-8168 6U CompactPCI 8-Axis Motion Control Card
  • ADLINK PCIe PXIe-8638 PCIe to PXIe Bus Expansion Kit
  • ADLINK PCIe GIE7x series acquisition card
  • ADLINK PCIe-7396 96 96 channel TTL digital IO card
  • ADLINK PCI/MPC/PXI-8164 Three in One Motion Control Card
  • ADLINK PCI-8154 Four Axis Pulse Motion Control Card
  • ADLINK PCI-8134 Four Axis Servo/Stepper Motion Control Card
  • ADLINK NuPRO-E42 PICMG1.3 full-length SHB motherboard
  • ADLINK MXC-6600 series high-performance fanless extended industrial computer
  • ADLINK MXC-6000 series embedded industrial control computer
  • ADLINK MXC-2300 series fanless expandable embedded industrial computer
  • ADLINK MCM-204 Independent Ethernet DAQ User Manual
  • ADLINK MCM-100/102 Edge IoT Platform for Machine Condition Monitoring User’s Manual
  • ADLINK MXC-6400 series sixth generation Core Fanless Scalable Industrial Control Computer
  • ADLINK Matrix Full Series Fanless Embedded Industrial Control Computers
  • ADLINK GIE64+4-channel PoE Gigabit Vision Capture Card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series-C I/O Module
  • ADLINK EOS-1200 Embedded Vision Host
  • ADLINK DLAP-5200 series high-performance fanless AI industrial computer
  • ADLINK DLAP-4000 series embedded industrial control computer
  • ADLINK Matrix MXC-2000 Series Fanless Industrial Control Computer Specification
  • ADLINK DAQ -/DAQE -/PXI-2000 Series Multi functional Synchronous Acquisition Card
  • ADLINK cPCI-6520 6U CompactPCI Single Board Computer
  • ADLINK CM1-86DX3 PC/104 Single Board Computer
  • Honeywell DC1000 series PID temperature controller
  • ALSTOM MiCOM C264 Modular Substation Controller
  • EMERSON AMS 2140 Mechanical Health Analyzer
  • ADLINK NuPRO-E320 PICMG1.3 Full length Industrial Motherboard
  • ADLINK NuPRO-800 Series Full length Industrial SBC User Manual
  • ADLINK NuPRO-598 Industrial Single Board Computer
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer
  • ADLINK Express-BASE7 User Manual
  • ADLINK DLAP-211 Series Fanless Edge AI Platform Specification Manual
  • ADLINK PCI/LPCI/LPCIe/cPCI-723X series 32 channel isolated digital I/O card
  • ADLINK cPCI-6965 series 6U CompactPCI single board computer
  • ADLINK NuDAQ 7200 series high-speed digital I/O board
  • Linghua ADLINK DLAP Deep Learning Acceleration Platform Product Manual
  • DEIF TCM-2 thyristor control module
  • Installation Manual for DEIF MVR-200 Series Medium Voltage Protection Device
  • DEIF MDR-2 multifunctional differential relay
  • DEIF AOM-1 Analog Output Module
  • DEIF AGI 400 series industrial/marine touch screen
  • Installation Manual for DEIF BRW-1 Marine Wing Bridge Instrument
  • DEIF AGC200 Quick Start Guide
  • DEIF AGC Multi line 2 Generator Set ControllerProduct basic information
  • ABB SPA-ZC 400 Ethernet Gateway Installation and Debugging Manual
  • ABB REM 543/545 motor generator protection device
  • DEIF PPU 300 controller
  • DEIF Delomatic 4 Offshore/Ocean Platform Dedicated Generator Power Management System DM-4
  • DEIF Delomatic Modular Generator Set Integrated System
  • DEIF AGC-4 Mk II Generator Set Controller
  • DEIF AGC-4 diesel generator set integrated controller
  • DEIF Multi line 2 Series PPU Unit Power Management (PPM) Operation Manual
  • DEIF Multi line 2 V2.4X Installation Manual
  • Beckwith M-6280 Digital Capacitor Bank Controller
  • Beckwith M-3311 Transformer Protection Relay
  • Beckwith M-3311A Transformer Integrated Protection Device
  • Beckwith M-3310 Transformer Integrated Protection Device Specification
  • Beckwith M-0359 Syncrocloser Check Plus Application Guide for Synchronous Calibration Relay
  • Beckwith M-0293A On Load Tap changer Controller Application Guide
  • DEIF GPU-3 Synchronous/Asynchronous Generator Integrated Microcomputer Protection Controller
  • Installation Instructions for DEIF PPM-3
  • Beckwith M-3520 distributed power grid connected comprehensive protection device
  • Beckwith M-3430 generator comprehensive protection device
  • Beckwith M-2293B adapter panel
  • Beckwith M-2001C digital on load voltage regulator controller
  • Beckwith M-2001B Digital On Load Voltage Regulating Controller
  • Beckwith M-0388/M-0389 synchronous verification relay
  • Beckwith M-0193B synchronous closing device
  • Beckwith M-0115A Transformer Parallel Balancing Module
  • Beckwith M-0067E on load tap changer controller
  • Beckwith M-4272 Digital Motor Bus Switching System
  • Beckwith M-3311A Transformer Integrated Protection Device
  • Beckwith M-3425A Generator Integrated Protection Device Manual
  • Basler BE1-27/BE1-59/BE1-27/59 undervoltage/overvoltage relay
  • Basler AVC63-12/AVC125-10 excitation voltage regulator
  • Basler L301kc Color Three Line Array Camera Operation Manual
  • Basler CBS 212A Current Enhanced Excitation System
  • Basler BE3-25 synchronous check relay
  • Operation Manual for Basler BE1-32R/BE1-32O/U Direction Power Relay
  • Basler Electric PRS-250 Veri Sync Synchronous Relay
  • Basler Pilot Series Area Array Industrial Camera piA2400-17gc
  • Basler BE1-11g comprehensive protection device for generator
  • Basler VR63-4C/UL Analog Excitation Voltage Regulator
  • Basler BE1-DFPR distribution feeder protection relay