K-WANG
ABB 1SBP260056R1001 Advant Controller 31 Remote Unit
Basic Information
Product Overview:The ABB 1SBP260056R1001 Advant Controller 31 Remote Unit is an important part of the ABB automation control system. It is used as a remote unit to extend and enhance the functionality of the Advant Controller 31 system, enabling the system to be controlled and monitored over a wider range.
Physical characteristics: It is usually designed with a robust housing to suit the industrial environment. The housing materials generally have good corrosion resistance and mechanical strength to protect the internal circuitry from dust, moisture, vibration and other factors. Their compact size makes them easy to install in control cabinets or remote sites, and their moderate weight makes them easy to transport and install.
Functional Features
Remote Control Functions
Communication connectivity: The remote unit has a powerful communication function that enables it to communicate with the main controller (Advant Controller 31) over long distances via a variety of communication interfaces (e.g., Ethernet, serial interface, etc.). It supports standard industrial communication protocols such as Modbus, Profibus or ABB-specific internal communication protocols, ensuring reliable data transfer between the remote site and the main controller.
Distributed control capability: Allows distributed control strategies to be implemented at locations remote from the master controller. For example, in a large factory or complex industrial facility, specific control tasks can be assigned to remote units for processing, such as localised control of a group of equipment in a workshop, thus reducing the burden on the main controller and improving the overall responsiveness and control efficiency of the system.
Data Acquisition and Processing Functions
Multiple input interfaces: Equipped with multiple types of input interfaces, including digital and analogue input interfaces. The digital input interface can receive signals from various digital sensors (e.g. limit switches, push buttons, etc.), while the analogue input interface can process signals from analogue sensors (e.g. temperature sensors, pressure sensors, etc.), such as standard industrial analogue signals of 0 - 10V DC, 4 - 20mA, etc.
Data processing and pre-processing function: Processing and pre-processing of the collected data, such as signal filtering, data conversion, alarm judgement and other operations. In the process of data acquisition, the analogue signal can be filtered to remove noise interference and improve the accuracy of the data; it can also convert the collected raw data into a format suitable for system processing, and at the same time, judge whether to trigger the alarm conditions according to the pre-set alarm thresholds, and send the alarm information to the main controller in time.
Compatibility and Expandability
Compatibility with the system: Designed to be tightly integrated with the Advant Controller 31 system, it can seamlessly match the functions of the main controller. The programming environment, configuration parameters and database of the main controller can be shared, making it easy for users to incorporate remote units into the overall control system architecture when configuring and programming.
Strong expandability: Provide certain expansion interfaces to facilitate users to increase the number of input and output points, connect more external devices or expand communication functions according to actual needs. For example, digital or analogue input and output channels can be increased by adding expansion modules to adapt to the ever-changing needs of industrial process control.
Technical Parameters
Electrical parameters
Operating voltage range: generally have a wide operating voltage range, such as 18 - 30V DC or 85 - 264V AC, to adapt to different power supply conditions, and in this voltage range can work stably, power fluctuations have a certain degree of anti-jamming ability.
Input and output electrical characteristics: the input voltage range of digital input interfaces may vary depending on the specific configuration, e.g. the input voltage range of 24V DC input interfaces is usually 18 - 30V DC and the input current is usually between a few milliamps and tens of milliamps; analogue input interfaces are capable of handling a wide range of analogue signals, and the signal resolution may be up to 12 - 16 bits, to ensure high-precision data acquisition. For output interfaces (if available), the output current and voltage are also rated accordingly to meet the requirements of driving external devices.
Communication Parameters
Communication interface types and rates: These include Ethernet interfaces (RJ45) and serial interfaces (e.g. RS-232, RS-485). The communication rate of Ethernet interface may support 10/100Mbps or higher, and the baud rate of serial interface can be set in a wide range, such as 9600bps - 115200bps, in order to meet different data transmission requirements. The communication interface supports a variety of communication protocols, such as Modbus, Profibus and so on.
Communication distance and anti-interference ability: Under different communication interfaces, there are corresponding communication distance limits. For example, when communicating through Ethernet, a long communication distance can be achieved under suitable network environment; when communicating through serial interface, the communication distance can also meet the requirements of general industrial sites. At the same time, the module has good anti-interference ability, through the use of shielded cable, signal isolation and other technologies to reduce the impact of electromagnetic interference on the quality of communication.
User name | Member Level | Quantity | Specification | Purchase Date |
---|