The optional Fiber Terminal Block enables PACMotion controller to connect remote I/O over
a fiber cable. The Fiber Terminal Block is DIN rail mounted and can be up to 100 meters
away from the PACMotion module. The module is configurable per point for 5 VDC, 24 VDC
and analog I/O. The Fiber Terminal Block provides a unique ID that prevents connection to
wrong PACMotion modules. The module supports up to 5 incremental encoders without
marker or 4 encoders with marker pulse.
GE IC695FTB001 PACMotion I/O Fiber Terminal Block
Programmable Controllers
PACMotion I/O Fiber Terminal Block
The optional Fiber Terminal Block enables PACMotion controller to connect remote I/O over
a fiber cable. The Fiber Terminal Block is DIN rail mounted and can be up to 100 meters
away from the PACMotion module. The module is configurable per point for 5 VDC, 24 VDC
and analog I/O. The Fiber Terminal Block provides a unique ID that prevents connection to
wrong PACMotion modules. The module supports up to 5 incremental encoders without
marker or 4 encoders with marker pulse.
IC695FTB001
Product Name PACMotion I/O Fiber Terminal Block
Lifecycle Status Active
Module Type I/O Terminal Block for PACMotion
Mounting/Dimensions
35 mm DIN Rail
(5.56 W x 4.94 H x 2.46 D inches;
141.2 W x 125.5 H x 62.5 D mm)
Interface to PACMotion Module
Fiber Optic Cable.
Maximum cable length is 100 meters;
Interface uses a unique ID for each
PMM/FTB pair to prevent cross-connection.
Power Requirements 19.2 VDC —28.8 VDC; 0.45 Amps @ 24 V
24 V Outputs (differential)
Eight optically isolated; source;
open load & short detection.
2 groups of 4; 0.5 A max. per point;
4 A max. per group
24 V General Purpose Inputs Sixteen optically isolated;
source/sink 4 groups of 4
5 V Outputs (differential) Four RS422 Line Driver with
short circuit protection; 48 mA max.
5 V Inputs (differential/single-ended) Six RS422 / RS485 Line Receiver
with fault detection
5 V Inputs (differential) Six RS422 / RS485 Line Receiver
with fault detection
Analog Inputs Two, ±10V differential 14 bit resolution
Analog Outputs Two, ±10V differential 14 bit resolution
24 V Power Output Reverse polarity protected
by replaceable fuse
5 V Power Output 0.5 amp max. electronic overload protected
Quad Encoder Open
Circuit Detection Yes
I/O Function Assignment Configurable I/O functions are assigned
during module hardware configuration
Terminal Header Options IC694TBxx32