K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
BENTLY 3500/04 Internal Barriers
❤ Add to collection

BENTLY 3500/04 Internal Barriers

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

BENTLY 3500/04 Internal Barriers

28756.00
¥28740.00
Weight:4.000KG
Quantity:
(Inventory: 31)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

BENTLY 3500/04 Internal Barriers


BENTLY 3500/04 Internal Barriers

Description

3500 Internal Barriers are intrinsically safe interfaces that provide explosion protection for transducer systems connected directly to the 3500 Machinery Protection System. The internal barriers are fully compatible with the 3500 System and provide a convenient and cost-effective solution for installing all types of transducer systems within a hazardous area.

Installation Guidelines

The internal barriers for a 3500 rack are incorporated in special Monitor I/O Modules. These barriers provide explosion protection for transducer systems that are connected to the 3500 system. An intrinsically safe (IS) earthing module provides the IS earth connection through the 3500 system backplane.

The IS Earth Module requires a dedicated I/O module position and precludes the use of this monitor position for other 3500 System modules. This limits a standard 19-inch rack to 13 monitor positions. Furthermore, a number of installation options are not available when internal barriers are installed in a 3500 rack.

New Rack Installations

The same rack can contain both internal barrier and standard I/O module types without compromising the separation between hazardous and safe area field wiring. The External Termination option is not available for I/O modules with internal barriers because hazardous area approvals do not allow the use of intrinsically safe wiring within a multi-cored cable assembly.

Monitors that contain Triple Modular Redundant (TMR) rack options cannot use internal barrier I/O modules since connecting a transducer to multiple I/O module inputs will compromise the integrity of the IS system. A rack that contains any internal barrier module must have a 3500/04-01 IS Earthing Module to provide the Barrier Module IS earth connection.

I/O Module Positioning

Internal barrier I/O modules have an increased depth over that of standard barrier I/O modules. Consider the rack position with respect to adjacent modules to ensure that you can easily access the I/O modules during maintenance.

Internal barrier I/O and IS Earthing modules can occupy any general-purpose rack position and can be adjacent to standard I/O module types without compromising the 50 mm (2 in) physical separation requirement between safe and hazardous area field wiring.

Follow these guidelines when positioning I/O modules:

· Group all internal barrier I/O modules in adjacent rack positions to simplify the installation. 

· Place the IS Earthing Module in a rack position that provides easy access for routine online maintenance. 

· Consider the IS Earthing Module's positioning relative to adjacent internal barrier I/O modules and cabinet bulkheads.

Cabinet and Panel Installations

The internal barrier I/O modules add approximately 50 mm (2 in) to the depth of the rack to provide the 50 mm (2 in) physical separation between safe and hazardous area field wiring. Hence, a standard rack with internal barrier modules will not fit into a 400 mm cabinet.

The bulkhead rack version is available for installations that require this cabinet type. A standard rack with internal barrier modules will fit comfortably in a 600 mm cabinet and the 3500/06 Weatherproof Housing.

We recommend the following installation guidelines for the internal barriers within a cabinet or panel:

· The positioning of the hazardous and safe area connectors dictates installations route the hazardous area field wiring above the 3500 rack and safe area wiring below the 3500 Rack. 

· Installations should carefully route the safe area wiring from the bulkhead version along the top of the 3500 rack to maintain the 50 mm (2 in) separation between safe and hazardous area wiring.

Compliance and Certifications FCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

· This device may not cause harmful interference. 

· This device must accept any interference received, including interference that may cause undesired operation.

Models that may be of interest

BENTLY 2300/25 Vibration Monitors

bently 2300/20 Vibration Monitors

BENTLY 1900/27 Vibration Monitor

BENTLY 3500-33 16-Channel Relay Module

bently 106M1081-01 Power Input Module


  • ADLINK NuPRO-852 Full length PICMG1.0 Industrial Single Board Computer
  • ADLINK NuPRO-841 Full length Industrial SBC
  • ADLINK NuPRO-590/591/592 series Socket7 full-length industrial SBC
  • ADLINK MXE-5500 series fanless embedded industrial computer
  • ADLINK MXE-200/200i Fanless Embedded Machine
  • ADLINK cPCI-6770 series CompactPCI CPU board
  • ADLINK NuPRO-A301 standard PICMG 1.0 full-length industrial SBC single board computer
  • ADLINK NuPRO-965 PICMG 1.3 SHB Express Full length Industrial Motherboard
  • ADLINK NuPRO-935A Full length PICMG1.0 Industrial Single Board Computer
  • ADLINK NuPRO-865 Full length Single Board Computer
  • ADLINK NuPRO-840 DV/LV Full Length PICMG Industrial Single Board Computer
  • ADLINK NuPRO-770 series full-length industrial single board computer
  • ADLINK NuPRO-595 series half length Socket 7 industrial motherboard
  • ADLINK cPCI-6840 series 6U CompactPCI single board computer
  • Foxboro 43AP series pneumatic indicator controller (PSS 3-1B3 A)
  • ADLINK cPCI-3720 Series 3U Low Power CompactPCI Single Board Computer
  • ADLINK NuPRO-E47, PICMG 1.3 full-length industrial SHB system motherboard
  • ADLINK NuPRO-E43 PICMG 1.3 full-length system motherboard
  • ADLINK NuPRO-780 series full-length industrial CPU board
  • ADLINK cPCI-6965 series 6U CPCI single board computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB interface card
  • Rittal SK 3241.700 Blue e+Fan Filter Unit
  • ADLINK cPCI-8168 6U CompactPCI 8-Axis Motion Control Card
  • ADLINK PCIe PXIe-8638 PCIe to PXIe Bus Expansion Kit
  • ADLINK PCIe GIE7x series acquisition card
  • ADLINK PCIe-7396 96 96 channel TTL digital IO card
  • ADLINK PCI/MPC/PXI-8164 Three in One Motion Control Card
  • ADLINK PCI-8154 Four Axis Pulse Motion Control Card
  • ADLINK PCI-8134 Four Axis Servo/Stepper Motion Control Card
  • ADLINK NuPRO-E42 PICMG1.3 full-length SHB motherboard
  • ADLINK MXC-6600 series high-performance fanless extended industrial computer
  • ADLINK MXC-6000 series embedded industrial control computer
  • ADLINK MXC-2300 series fanless expandable embedded industrial computer
  • ADLINK MCM-204 Independent Ethernet DAQ User Manual
  • ADLINK MCM-100/102 Edge IoT Platform for Machine Condition Monitoring User’s Manual
  • ADLINK MXC-6400 series sixth generation Core Fanless Scalable Industrial Control Computer
  • ADLINK Matrix Full Series Fanless Embedded Industrial Control Computers
  • ADLINK GIE64+4-channel PoE Gigabit Vision Capture Card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series-C I/O Module
  • ADLINK EOS-1200 Embedded Vision Host
  • ADLINK DLAP-5200 series high-performance fanless AI industrial computer
  • ADLINK DLAP-4000 series embedded industrial control computer
  • ADLINK Matrix MXC-2000 Series Fanless Industrial Control Computer Specification
  • ADLINK DAQ -/DAQE -/PXI-2000 Series Multi functional Synchronous Acquisition Card
  • ADLINK cPCI-6520 6U CompactPCI Single Board Computer
  • ADLINK CM1-86DX3 PC/104 Single Board Computer
  • Honeywell DC1000 series PID temperature controller
  • ALSTOM MiCOM C264 Modular Substation Controller
  • EMERSON AMS 2140 Mechanical Health Analyzer
  • ADLINK NuPRO-E320 PICMG1.3 Full length Industrial Motherboard
  • ADLINK NuPRO-800 Series Full length Industrial SBC User Manual
  • ADLINK NuPRO-598 Industrial Single Board Computer
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer
  • ADLINK Express-BASE7 User Manual
  • ADLINK DLAP-211 Series Fanless Edge AI Platform Specification Manual
  • ADLINK PCI/LPCI/LPCIe/cPCI-723X series 32 channel isolated digital I/O card
  • ADLINK cPCI-6965 series 6U CompactPCI single board computer
  • ADLINK NuDAQ 7200 series high-speed digital I/O board
  • Linghua ADLINK DLAP Deep Learning Acceleration Platform Product Manual
  • DEIF TCM-2 thyristor control module
  • Installation Manual for DEIF MVR-200 Series Medium Voltage Protection Device
  • DEIF MDR-2 multifunctional differential relay
  • DEIF AOM-1 Analog Output Module
  • DEIF AGI 400 series industrial/marine touch screen
  • Installation Manual for DEIF BRW-1 Marine Wing Bridge Instrument
  • DEIF AGC200 Quick Start Guide
  • DEIF AGC Multi line 2 Generator Set ControllerProduct basic information
  • ABB SPA-ZC 400 Ethernet Gateway Installation and Debugging Manual
  • ABB REM 543/545 motor generator protection device
  • DEIF PPU 300 controller
  • DEIF Delomatic 4 Offshore/Ocean Platform Dedicated Generator Power Management System DM-4
  • DEIF Delomatic Modular Generator Set Integrated System
  • DEIF AGC-4 Mk II Generator Set Controller
  • DEIF AGC-4 diesel generator set integrated controller
  • DEIF Multi line 2 Series PPU Unit Power Management (PPM) Operation Manual
  • DEIF Multi line 2 V2.4X Installation Manual
  • Beckwith M-6280 Digital Capacitor Bank Controller
  • Beckwith M-3311 Transformer Protection Relay
  • Beckwith M-3311A Transformer Integrated Protection Device
  • Beckwith M-3310 Transformer Integrated Protection Device Specification
  • Beckwith M-0359 Syncrocloser Check Plus Application Guide for Synchronous Calibration Relay
  • Beckwith M-0293A On Load Tap changer Controller Application Guide
  • DEIF GPU-3 Synchronous/Asynchronous Generator Integrated Microcomputer Protection Controller
  • Installation Instructions for DEIF PPM-3
  • Beckwith M-3520 distributed power grid connected comprehensive protection device
  • Beckwith M-3430 generator comprehensive protection device
  • Beckwith M-2293B adapter panel
  • Beckwith M-2001C digital on load voltage regulator controller
  • Beckwith M-2001B Digital On Load Voltage Regulating Controller
  • Beckwith M-0388/M-0389 synchronous verification relay
  • Beckwith M-0193B synchronous closing device
  • Beckwith M-0115A Transformer Parallel Balancing Module
  • Beckwith M-0067E on load tap changer controller
  • Beckwith M-4272 Digital Motor Bus Switching System
  • Beckwith M-3311A Transformer Integrated Protection Device
  • Beckwith M-3425A Generator Integrated Protection Device Manual
  • Basler BE1-27/BE1-59/BE1-27/59 undervoltage/overvoltage relay
  • Basler AVC63-12/AVC125-10 excitation voltage regulator
  • Basler L301kc Color Three Line Array Camera Operation Manual
  • Basler CBS 212A Current Enhanced Excitation System
  • Basler BE3-25 synchronous check relay
  • Operation Manual for Basler BE1-32R/BE1-32O/U Direction Power Relay
  • Basler Electric PRS-250 Veri Sync Synchronous Relay
  • Basler Pilot Series Area Array Industrial Camera piA2400-17gc
  • Basler BE1-11g comprehensive protection device for generator
  • Basler VR63-4C/UL Analog Excitation Voltage Regulator
  • Basler BE1-DFPR distribution feeder protection relay
  • Basler CBS310/CBS320 current strong excitation system
  • Basler UFOV250A/UFOV260A Low Frequency Overvoltage Module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F PMG excitation regulator
  • Basler DECS-400 Digital Excitation Control System
  • Basler DGC-2020 Digital Generator Set Controller
  • Basler MVC-300 Electronic Manual Excitation Controller
  • Basler MVC-104/MVC-108/MVC-232 manual excitation controller
  • Basler SSR32-12/SSR63-12/SSR125-12 Static Excitation Voltage Regulator
  • Basler SR4A/SR8A Analog Excitation Voltage Regulator
  • Basler BE2000E Digital Excitation Voltage Regulator
  • Basler DECS-2100 Digital Excitation System
  • Basler BE1-851 Overcurrent Protection Device Manual
  • Basler APR 63-5 Voltage Regulator
  • Basler BE1-FLEX Integrated Protection Control System
  • Basler BE1-700V digital voltage protection relay
  • Basler BE1-87B high impedance bus differential relay
  • Basler BE1-40Q demagnetization relay
  • Basler BE1-60 Voltage Balance Relay
  • Basler BE1-47N negative sequence voltage phase sequence relay