K-WANG
ABB GJR5253200R1161 MODBUS Communication Processor
Basic Information
Type: GJR5253200R1161 07KP93, where 07KP93 is the specific number of the product in the ABB product line.
Place of origin: Sweden, its Swedish origin reflects ABB's high-end manufacturing processes and quality standards in industrial automation.
Size and weight: its package size of about 6 inches × 4 inches × 6 inches (15cm × 10cm × 15cm), weighing about 0 pounds 15 ounces (0.43kg), this small and lightweight design, easy to install and deploy in a variety of industrial environments, and can be flexible to adapt to different space requirements.
Performance Features
Communication Features:
Supports MODBUS protocol: specially designed to handle MODBUS communication, it supports MODBUS RTU mode, which allows it to perform master or slave functions and communicate with other devices via RS232 or RS485 interface. This makes it easy to integrate with a large number of industrial equipment, instruments and control systems that support the MODBUS protocol for fast and accurate data exchange.
Dual communication channels: Equipped with 2 communication channels, it increases the flexibility and reliability of communication. Users can connect different devices to different channels according to the actual application requirements, or set up redundant channels to ensure that data can still be transmitted normally in the event of a communication line failure.
Electrical Characteristics :
Working voltage: the rated power supply voltage is 24V DC, which is widely used in industrial control field, with the advantages of high stability, good security, etc. It can provide reliable power support for the stable operation of the communication processor.
Low Power Consumption: The maximum current consumption is 0.2A, and the maximum power consumption is 5W. The low power consumption design not only reduces the operation cost, but also helps to improve the reliability and stability of the equipment, and reduces the risk of failures due to heat and other problems.
Diagnostic and display functions :
LED Indicators: The panel is equipped with a total of 17 LED indicators, which are used to display the operating status of the device, communication status and various fault messages. By observing the brightness and blinking frequency of these indicators, users can quickly and intuitively understand the working condition of the equipment, and find and solve potential problems in a timely manner.
Fault diagnosis: With perfect fault diagnosis function, it can automatically detect and report communication faults, power supply faults, hardware faults and other abnormal situations. When a fault occurs, it will send out an alarm signal through the LED indicator or other means, and provide detailed fault codes and diagnostic information to help maintenance personnel to quickly locate and troubleshoot the problem and reduce equipment downtime.
Configuration and Installation :
Flexible configuration: address setting and configuration code switches are located under the cover on the right side of the housing, users can set the communication address, baud rate, data bits, stop bits and other parameters of the device by simply operating these switches to meet different application scenarios and system requirements.
Convenient installation: The detachable screw-type terminal block is used for connection, which is a solid and reliable connection method, and at the same time, it is easy to install and disassemble, which can effectively improve the efficiency of on-site construction. The specifications of the terminals are 1×2.5mm² or 2×1.5mm² wires for the power supply terminal and CS31 system bus, and 1×1.5mm² wires for the other terminals, which meets the needs of different signal transmission.
Applications
Industrial automation: In various industrial automation production lines, such as automotive manufacturing, machining, electronic manufacturing and other industries, the communication processor can be used to achieve MODBUS communication between PLC, DCS system and various intelligent devices. For example, it can collect data from temperature sensors, pressure sensors, flow meters and other instruments in the production line to the control system, and at the same time send the instructions of the control system to the corresponding actuators accurately, so as to realise the precise control and monitoring of the production process.
Energy management system: In the energy management system of electric power, petroleum, chemical and other energy industries, it can be used to connect energy metering equipment such as electricity meter, water meter, gas meter, and energy control equipment such as frequency converter and soft starter, to achieve the collection, monitoring and analysis of energy data, and to help enterprises optimize the use of energy and reduce energy consumption and costs.
Intelligent building: In the building automation system of intelligent building, it can be used to connect the equipment in air-conditioning system, lighting system, water supply and drainage system, etc., and realise remote monitoring and intelligent management of various equipments in the building. For example, through MODBUS communication, the operating parameters of air-conditioning units are transmitted to the central monitoring system to achieve energy-saving control of the air-conditioning system and early warning of faults; the switching status and brightness of the lighting system are fed back to the control centre to achieve intelligent control of lighting and energy management.
Water treatment and environmental protection industry: In the automation control system of water treatment plant, sewage treatment plant and other environmental protection fields, it can be used to connect water quality monitoring sensors, dosing equipment, pumps and valves, etc., to achieve automatic control of the water treatment process and water quality monitoring. Through MODBUS communication, the water quality data will be transmitted to the monitoring centre in real time, so that the treatment process can be adjusted in time to ensure that the effluent water quality meets the standard.