K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
GE IC200ALG331 Analog Output Module
❤ Add to collection

GE IC200ALG331 Analog Output Module

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

The Analog Output Module with 4 isolated outputs is an intelligent

module that controls to up to 4 analog devices.

7457.00
¥5678.00
Weight:1.100KG
Quantity:
(Inventory: 50)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

The Analog Output Module with 4 isolated outputs is an intelligent

module that controls to up to 4 analog devices.


GE IC200ALG331 Analog Output Module

In current mode, a separate power supply may be required for

isolated inputs.
Module features include:
ƒ
Four isolated 4-20mA current output channels
ƒ
Software configuration, no jumpers or switches
ƒ
Sixteen bit converter resolution
ƒ
High accuracy factory calibration
The following features are software-configurable:
ƒ
Per-channel selection of 4-20mA current or +/–10V voltage outputs
ƒ
Selection of default/hold last state operation
ƒ
Per-channel selection of default values
ƒ
Per-channel selection of under-range and over-range
diagnostics levels
ƒ
Per-channel selection of alarm levels
ƒ
Per-channel scaling
ƒ
Field re-calibration on command
Host Interface_______________________________________
The module receives 4 words of analog output data from the system.
Diagnostics ________________________________________
The module reports High/Low Limit, Over/Underrange, Open Wire,
Loss of Field Power Supply, and Non-volatile memory fault
diagnostics.
LED Indicators ______________________________________
The green FLD PWR LED indicates the presence of both logic
power and field power for the analog field-side circuits. It does not
indicate the presence of other supplies such as current loop supplies
on output points. The absence of either backplane or field power
turns off the FLD PWR LED.
The OK LED indicates module status:
ƒ
On green indicates normal operation.
ƒ
Flashing green indicates boot mode or update
ƒ
Flashing amber indicates self-diagnostic error.
ƒ
Off indicates no 3.3V power
Note that this module is the only one that has its OK LED located

before the FLD PWR LED in the A slot.

Module Characteristics
Channels 4 outputs
Module ID FFFF9805
Isolation:
User input to logic (optical)
and to frame ground,
Group to Group
Channel to channel
250VAC continuous; 1500VAC for 1 minute
Not applicable
250VAC continuous; 1500VAC for 1 minute
LED indicators FLD PWR LED indicates the presence of both logic
power and user power. OK LED indicates module
status.
Backplane current
consumption
5V output: 10mA maximum.
3.3V output: 115mA maximum
Configuration parameters Output default
External power supply:
Range
Current consumption
+18 to +30VDC including ripple
100mA maximum plus load currents
Thermal derating None
Diagnostics High/Low Limit, Over/Underrange, Open Wire, Loss of
Field Power Supply, Non-volatile memory fault
Output Characteristics
Output operating range Current mode: +1 to 20mA
Voltage mode: +/-10VDC
Accuracy at 25 degrees C +/- 0.1% maximum of full scale
Temperature coefficient Current mode: 45ppm/°C typical, 90 ppm/°C maximum
Voltage mode: 30ppm/°C typical, 60 ppm/°C maximum
Load characteristics Current mode: 0 to 1250 ohms
Voltage mode: 2K ohms minimum
Analog Resolution (1LSB) Current mode: 381 nA nominal
Voltage mode: 381 µV nominal
Update rate 7mS maximum
Channel-to-channel
crosstalk rejection
70dB minimum
Output default Hold Last State (default)
0 (configurable)
Preinstallation Check
Carefully inspect all shipping containers for damage. If any equipment is
damaged, notify the delivery service immediately. Save the damaged
shipping container for inspection by the delivery service. After unpacking
the equipment, record all serial numbers. Save the shipping containers
and packing material in case it is necessary to transport or ship any part
of the system.


Field Wiring Terminals
Terminal assignments for the module are shown below.
Number Connection Number Connection
A1 No connection B1 I1+
A2 Shield Ground B2 I1-
A3 No connection B3 V1+
A4 Shield Ground B4 V1-
A5 No connection B5 I2+
A6 Shield Ground B6 I2-
A7 No connection B7 V2+
A8 Shield Ground B8 V2-
A9 No connection B9 I3+
A10 Shield Ground B10 I3-
A11 No connection B11 V3+
A12 Shield Ground B12 V3-
A13 No connection B13 I4+
A14 Shield Ground B14 I4-
A15 No connection B15 V4+
A16 Shield Ground B16 V4-
A17 No connection B17 DC -
A18 No connection B18 DC+
A 24 volt power supply must be connected to B17 and B18 to
operate the module.
Voltage outputs are powered from the module. For each channel, V+
is positive with respect to V- when the channel’s output data is
positive.
Current outputs act as current regulators and require a supply to
power the load. The current loop can be connected either as a
current source or as a current sink to the load.
The loads are isolated if the loop supply is isolated. However, if the
module supply is also used as the loop supply, the loads are not
isolated.
Wiring Connections for Carriers with Two Rows of Terminals
Shielded twisted pair cable is recommended for the analog channel
connections.
If the module is installed on a Terminal-style I/O Carrier or a Compact
Terminal-style I/O Carrier, the cable shield can be connected directly to
the carrier.
If the module is installed on a Connector-style I/O Carrier, the cable
shield can be connected directly to an Interposing Terminal. A shielded
interposing cable (shielded cables are available separately) must be
used between the Connector-style I/O Carrier and the Interposing
Terminal.
An Auxiliary I/O Terminal Strip can also be added to the Interposing
Terminal if additional shield connections are required.


  • Eaton LZM series molded case circuit breaker
  • Pilz PSWZ X1P Safety Static Monitoring Relay
  • Keyence CV-3502P/CV-3000 series visual system
  • Pro face GP2400/2500/2600 series programmable human-machine interface (HMI)
  • Siemens SINAMICS S120 AC frequency converter
  • Allen Bradley 160-IB1 InterBus Communication Module
  • MX321 AVR Automatic Voltage Regulator
  • GE Multilin MM2 Motor Manager 2 Manual
  • SIEMENS C500 microcontroller family architecture and instruction set description
  • HORIBA SEC-Z500X Series Digital Mass Flow Controller
  • QUBE Servo 2 integrated rotary servo teaching experimental platform
  • Schneider Telemecanique TSX17 Micro PLC Communication Module
  • GE DC Drives (BCH series) DC Speed Governor
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB COMBIVERT F5 elevator dedicated frequency converter
  • TOSHIBA TOSBERT VF-S15 Inverter Description
  • LS Power Generation SV-IG5A Series Inverter Easy Operation Instructions
  • Allen Bradley GuardPLC 1200/1600/1800/2000 Series Controller Systems
  • Installation Guide for Omron C1000H/C2000H Series PLC
  • Omron F160 Vision Sensor
  • Bonner Q45U series short range analog output ultrasonic sensor
  • Schneider C60H-DC C-curve DC supplementary protector
  • Omron SYSMAC CPM2B series board PLC
  • Omron C500 series rack mounted PLC
  • Mitsubishi language hardware manual for Mitsubishi FX0/FX0N series PLC
  • PULS QS40.241/QS40.241-C2 models 24V/40A/960W single-phase rail mounted switching power supply
  • Eaton XV-102-L series industrial touch screen HMI
  • Omron FZ5 series visual system
  • Schneider TSX 47-10/20/25 series modular sequential PLC
  • ABB Procontic CS 31 Distributed Automation System Description
  • OMRON H8PR series electronic cam controller
  • OMRON 3G3MX2 frequency converter
  • Safety and installation wiring instructions for GP477R-EG11 touch human-machine interface
  • I/O module for Siemens 3RK series AS-i SlimLine Compact control cabinet
  • OMRON NS Series Programmable Terminal Web Interface User Manual
  • OMRON Z4M laser displacement sensor
  • HIMMERWERK SINUS series high-frequency induction heating generator
  • OMRON CP series CP1E CPU unit
  • OMRON ZFX-C series intelligent visual sensor
  • OMRON ZFV series intelligent visual sensor
  • OMRON CJ series CPU unit operation instructions
  • Murr Electronics 7000-41034-0400400 M12 Power Connector Instructions
  • OMRON ZFX series simple visual sensor
  • REER ULISSE UNC safety photoelectric protection device
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • OMRON CPM2C Programmable Controller
  • Yaskawa ∑ - V series SGDV servo drive matching
  • OMRON SYSMAC CP1H series PLC (X/XA/Y type) operating instructions
  • OMRON SYSMAC C20K/C28K/C40K/C60K series K-type programmable controllers
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Controller
  • Yaskawa ∑ - II series SGMBH servo motor+SGDH servo driver
  • Yaskawa VS-616PC5/P5 series variable torque frequency converter
  • OMRON 3G3SV series book style fully digital low-noise frequency converter
  • Pro face GP-370 series human-machine interface (HMI)
  • OMRON FQ2 series integrated intelligent visual sensor
  • SONY SH800SFP cell sorter BioImaging Facility IST Austria
  • OMRON 3F88L-160/162 cam locator
  • KEB COMBIVERT F4 series frequency converter
  • OMRON CJ Series PLC (CJ1H-R/H/G, CJ1M, CJ1) Operating Instructions
  • Schneider C60H-DC C-curve DC supplementary protector
  • OMRON 3G3MV Multi functional Compact Inverter
  • OMRON CQM1H series modular PLC
  • Huichuan MCTC-ARD-C Elevator Automatic Rescue Device (ARD)
  • SolaHD SDN-D series rail mounted high-performance power supply
  • OMRON C200H Series PLC (CPU01-E/03-E/11-E) Operating Instructions
  • Allen Bradley 1336 PLUS series AC frequency converter
  • OMRON SYSDRIVE 3G3KV-EV2 series frequency converter
  • OMRON SYSMAC One NSJ series programmable controller
  • Technical specifications for Legrand Megatiker M4 thermal magnetic circuit breaker and MS4 isolating switch
  • OMRON ZX series (ZX-L-N) laser intelligent sensor
  • Saia PCD1 series compact programmable controller
  • OMRON NT series programmable terminal
  • Yaskawa F7 series (CIMR-F7U) frequency converter
  • Rockwell 1491/1494 series isolation switch and fuse base
  • Omron NA Series Programmable Terminal Device Connection Instructions
  • Eaton XV-102-L Series Touch Screen Display
  • Eaton XV-102-L series touch display screen
  • Siemens SINUMERIK Measurement Cycle User Guide
  • ELAU PacDrive C600 High Performance Motion Controller
  • ELAU PacDrive SM series permanent magnet synchronous servo motor
  • Bently Nevada Orbit 60 Series Integrated Unit Protection and Condition Monitoring System
  • YOKOGAWA STARDOM FCN-RTU Autonomous Controller
  • Fireye InSight ® II Marine Flame Scanner
  • Installation and Use Instructions for ABB VSC 7.2/12kV-400A Vacuum Contactor
  • Rexroth Bosch Group VT 2000-52 (5X series) Electrical Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB Relay Retrofit Program for SPACOM to REX615 Product Guide
  • Meggitt C327895 gas metering valve
  • Moog G77X/-77X series high-performance flow control servo valve
  • WOODWARD 2301E Digital Load Sharing and Speed Control for Engines
  • ABB UNITROL ® 1000 series compact IGBT automatic voltage regulator
  • ABB UNITROL ® High end excitation control system for 6000 synchronous generators/motors
  • Rexroth Bosch Group HNC100 Programmable Digital Axis Controller
  • Lenze 8400 StateLine C Inverter Operating Instructions
  • Leybold PENNINGVAC PR25/PR26/PR27/PR28 series passive cold cathode Penning vacuum gauge tube
  • Leybold SOGEVAC DI&BI series oil lubricated rotary vane vacuum pump
  • Leybold THERMOVAC TTR 91/96/911/916 N series vacuum transmitter
  • Leybold TTR 101 series vacuum transmitter
  • Honeywell TC847A1004 Reflective Linear Beam Smoke Detector
  • Oerlikon Leybold Vacuum TURBOVAC series turbo molecular pump operation guide
  • Leuze electronic DDLS 200 series bus type infrared optical data transmission equipment
  • Lam Research 853-012123-004 model harmonic drive component
  • LZS-A1000-3 Power Installation, Operation, and Maintenance Instructions
  • MTL2000 series intrinsically safe isolation safety barrier
  • MTS Temposonics ® GB series (GBS/GBN) analog magnetostrictive linear displacement sensor
  • MTS Temposonics ® R-Series magnetostrictive absolute non-contact displacement sensor
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik family of industrial automation connection and control solutions
  • Nabtesco RV series high-precision reducer
  • NACHI-FUJIKOSHI 2020 Industrial Robot Full Series Products
  • ESD series electro-hydraulic proportional flow directional control valve
  • NEC FC-9801X Industrial Factory Computer
  • GE Vernova Mark VIeS Functional Safety System
  • Typical application cases of NI CompactRIO and sbRIO products
  • NI Single-Board RIO Embedded Control and Acquisition Devices
  • NI SHC68-68-EPM high-performance shielded cable
  • NI SCXI-1349 Shielded Cable Adapter Installation Guide
  • How to install NI SCXI chassis?
  • SNAP PAC System Specification Guide
  • PacSci 6410 Stepper Motor Subdivision Driver
  • TIDA-010210 11kW bidirectional three-phase GaN-ANPC
  • Pepperl+Fuchs K-System isolated safety barrier system
  • Pacific Scientific Powermax II P21NRXS-LNS-NS-03 NEMA 23 specification hybrid stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific's full range of brushless servo drives
  • Pacific Scientific SCE900 series single axis brushless servo drive