The Redundancy Memory Xchange (RMX) module operates as a dedicated link between
CPUs in an RX3i Hot Standby CPU (IC695CRU320) Redundancy system. The RMX modules
provide a path for transferring data between the two redundancy CPUs in the redundant
system. A complete communications path consists of one RMX in the primary unit, one RMX
in the secondary unit, and two high-speed fiber optic cables connecting them to each other.
One or two redundancy links are supported per high availability CPU.
GE IC695RMX128 High Availability Data Synch
PACSystems RX3iProgrammable Controllers
High Availability Data Synch
The Redundancy Memory Xchange(RMX) module operates as a dedicated link between
CPUs in an RX3i Hot Standby CPU (IC695CRU320)Redundancy system. The RMX modules
provide a path for transferring data between the two redundancy CPUs in the redundant
system. A complete communications path consists of one RMX in the primary unit, one RMX
in the secondary unit, and two high-speed fiber optic cables connecting them to each other.
One or two redundancy links are supported per high availability CPU.
IC695RMX128
RX3i Control Memory Xchange Module for
Product Name
Peer to Peer network.128Megbytes of
user shared memory.
Lifecycle Status
Active
Module Type
High Availability Data Syncronization Link
Backplane Support
Universal Backplane Only. Uses PCI Bus.
Sync Link Speed
2.1 Gbits/s
Communications Data Rate
2.12Gbaud
Synchronzed Link Transfer Rate
43 Mbyte/s (4 byte packets) to
174 Mbyte/s(64 byte packets)
Maximum Data Syncronization
Up to 2 megabytes. Twice per Scan.
Bus Diagnostics
Network error detection.
Redundant RMX Support
Yes
Maximum Distance Between
Redundant Controllers
300 meters
-Fiber optic LC type, conforms to IEC 61754-20
Connector Type
-Zirconium ceramic ferrule
-Insertion loss: 0.35 dB (maximum)
-Return loss:-30dB
Internal Power Used
660 mA @ +3.3 VDC 253 mA @ +5 VDC
Number of Slots Module1
Occupies on Backplane

Baseplates
RX3i baseplates are available in 7, 12 and 16 slot configurations to the meet the needs
of your application. The RX3i Universal baseplates support hot swap capability to reduce
downtime. Expansion bases are available in 5 and 10 slot versions to maximize flexibility.
IC695CHS007
IC695CH5012
IC695CH5016
IC694CHS398
IC693CHS399
IC694CHS392
IC693CHS393
PACSystems RX3i
PACSystems RX3i
PACSystems RX3i
PACSystems RX3i
PACSystems RX3i
PACSystems RX3i
PACSystems RX3i
7 slot high s peed
12 slot high speed
16 slot high speed
serial 5-slot
serial5-slot Remote
serial 10-slot
serial 10-slot
controller base
controllerbose
controller base
Expansion
Baseplate
Expansion
Remote Baseplate
Product Name
supports only
supports PO
supports Pa
Baseplate
(serial bus onlyi
Baseplate
(serial bus onlyl
5 serial bus slots
and serial bus
and serial bus
(serial bus only)
(serial bus onlyl
supported.
Notexpandable.
Lifecycle Status
Active
Active
Active
Active
Active
Active
Active
Universal Control-
Universal
Universal
Standard I/O
Standard I/O
Standard IVO
Standard VO
Module Type
ler and VO Base
Controllerand
Controller and
VO Base
I/O Base
Supports both
Supports both
Supports both
Supports High
Supports High
Supports High
Supports High
Backplane Support
PCI and High
PCIand High
PCI and High Speed Speed Serial Only.
Speed Serial Onily.
Speed Serial Only. Speed Serial Only.
Speed Serial
Speed Serial.
Serial
No PCI support.
No PCI support.
No PCI support.
No PCI support.
Module Hot Swap Support
Ves
Yes
Yes
No
No
No
No
Controller Base
Controller Base
Controller Base
Expansion
Expansion
Expansion
Expansion
and Ethernet
and Ethernet
and Ethernet
Baseplate Option
Expansion Base.
Expansion Base
Expansion Base
No local
base expansion
Distance
N/A
N/A
N/A
Up to 50 feet
Up to 700 feet
Up to 50 feet
Up to 700 feet
Number of Slots
7
12
16
5
5
10
10
Dimension
10.43x 5.57 x5.8018.01x5.57x5.80
23.7x5.57x5.80
10.43x5.12x5.5910.43x 5.12x5.5917.44x 5.12x5.5917.44x5.12x 5.59
(W xH xD) in. (mm)
(265x141.5x
(457.5x141.5x
(601.98x 1415 x
(245 x130x 142)(245x130x 142)(443 x130x 142](443x 130x142)
147.32)
147.32)
147.32)
Interal Power Used
600 mA@33VDC600 mA@3.3VDC:600 mA @3.3 VDC:170 mA@5VDC
480 mA@5VDC150 mA5 VDC
:460 mA@5VDC
240 mA 5 VDC
240 mA @ 5 VDC