K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB PGC5000 Process gas chromatograph
❤ Add to collection

ABB PGC5000 Process gas chromatograph

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

The PGC5000 Generation 2 Process Gas Chromatograph (analyzer) separates and measures the individual components of gas or  liquid samples. It automatically samples and analyzes process streams, using an appropriate interface to control analytical  functions. This interface may be a Local User Interface (LUI) that utilizes operational software located on the Master Controller,  or it may be a Remote User Interface (RUI) that has the same operational software on a PC. When the text uses the term “user  interface,” it refers to either the LUI or RUI, whichever applies to the particular system.

12125.00
¥10005.00
Weight:2.200KG
Quantity:
(Inventory: 50)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

The PGC5000 Generation 2 Process Gas Chromatograph (analyzer) separates and measures the individual components of gas or  liquid samples. It automatically samples and analyzes process streams, using an appropriate interface to control analytical  functions. This interface may be a Local User Interface (LUI) that utilizes operational software located on the Master Controller,  or it may be a Remote User Interface (RUI) that has the same operational software on a PC. When the text uses the term “user  interface,” it refers to either the LUI or RUI, whichever applies to the particular system.


ABB PGC5000 Process gas chromatograph

The PGC5000 Generation 2 analyzer is compatible with version 4.2.1. and greater, of the STAR Data Management System.

Each analyzer has a temperature code (T-Rating) listed on the nameplate. This T-Rating indicates the temperature classification

of the area in which the analyzer has been designed to operate. T-Ratings and area classifications for analyzer locations are

determined and supplied by the customer.

The standard analyzer consists of a Master Controller and associated ovens. This configuration has the Master Controller

connected to the ovens through an Ethernet switch (see Figure 3.1).

Ovens with Integrated Controllers consist of only the associated ovens. For this configuration there is no Master Controller, and

the user interface is accessed remotely (see Figure 3.2).

Fig. 3.2. Oven with Integrated Controller Connections

An Important Documents CD-ROM comes with the analyzer. Included on this CD are data sheets, installation drawings, and

replacement parts lists needed to support installation and operation of the analyzer. This manual refers to these data sheets

and drawings as the “Data Package.”

3.2 Drawings

Since analyzer configuration depends on the particular application, this manual does not contain generic engineering drawings

and diagrams. You should utilize the drawings, diagrams and replacement parts lists provided on the Data Package supplied

with your analyzer to ensure you are using the correct ones for your system.

3.3 Master controller

The Master Controller can support up to four ovens, in any combination of Class B and Class C ovens, depending on detector

configurations. If internal I/O modules are utilized, the maximum number of ovens per Master Controller is limited to three.

The Master Controller contains a Mounting Plate with a Single Board Computer (SBC) PCB, a Power Supply, one or more SBC

CAN Interface Cards, and optional Wago input/output modules. The front panel assembly has a touchscreen, liquid crystal

display (LCD), keypad, and front panel board.

No Master Controller is required for the Oven with Integrated Controller. The Oven with Integrated Controller can support up

to four ovens, in any combination of Class B and Class C Ovens, depending on detector configurations. The user interface is

accessed remotely, as described in Section 5.7.

The PGC5000 Generation 2 Master Controller can also act as a stand-alone RUI. In this configuration, the Master Controller will

not be connected to an oven, and it will not contain SBC CAN Interface Cards or Wago input/output modules. It will be

connected to the analyzer network via Ethernet and can connect to any PGC5000 Generation 2 device that is supported.

3.4 Class B oven

The Class B Oven, which comes in liquid and vapor versions, houses an isothermal oven which contains the anal

Carrier transports the vaporized sample into the column.

• The column then separates the components and passes them into the detector.

• The detector measures the sample across the range of high to low concentration.

The liquid sample valve is externally mounted on the right side of the Oven Compartment and extends through the isothermal

oven, allowing direct injection. It is actuated by a solenoid valve located in the Oven Electronics Compartment. The liquid

sample valve captures a specific volume of liquid sample below its bubble point, injects it into a temperature controlled

(vaporizing) chamber of the LSV, which then sends the vaporized sample into the oven.

3.4.2 Vapor version

The vapor version has a vapor input to the analysis, so it does not require a liquid sample valve. The duration of an analysis

cycle depends on the applications and consists of the following:

• Carrier gas transports the vaporized sample through the columns.

• The column then separates the components and passes them into the detector.

• The detector measures the sample across the range of high to low concentration.

3.5 Class C oven

The Class C Oven contains the same components as the Class B Oven, but it has the capability to handle more oven

components. The Class C Oven has a maximum of two detectors and a maximum of six valves.

3.6 Oven with integrated controller

The Oven with Integrated Controller can be either a Class B Oven or a Class C Oven. The distinguishing feature is that an Oven

with Integrated Controller has the Single Board Computer (SBC) PCB installed in the oven’s electronics compartment.

Since the Integrated Controller does not have a LUI, certain errors can occur that may not be visible through a RUI. The errors

may include, but not limited to: Configuration Errors, IP Address Conflicts, Name Conflicts, and Host Mismatch errors. If you

believe one of these errors has occurred or you cannot attach a RUI, place a blank USB drive into the USB slot on the SBC and

reboot the analyzer. The anal

Maintenance

4.1 Equipment and supplies required

Factory Data Sheets from the Data Package

Flow measuring device

4.2 Preventive maintenance

The oven design is specifically designed to eliminate the need for extensive and complex maintenance. Where preventive

maintenance procedures require particular time frames or intervals, maintain an inspection log and inspection data. Figure 4.1

lists inspection routines, with recommended time intervals for each routine. In addition, verify analyzer using a validation

sample periodically to ensure operating efficiency.

To aid in preventive maintenance, keep reference chromatograms for comparison and assisting with early

detection of issues as described in the Diagnostics and Troubleshooting section.

INTERVAL

Daily/Weekly

Weekly/Monthly

Monthly/Quarterly

ROUTINE

Perform a visual inspection of the analyzer and sample system.

Check:

• Instrument air supply

• Sample system flows and pressures

• Cylinder gas pressures; replace as necessary

Verify calibration and calibrate as necessary.

Compare resultant chromatograms with those in Data Package.

Check/set analytical flows and pressure as necessary per factory data

package.

Backup SBC tables after calibration and/or any changes to system

operational parameters.

Check carrier line dryers; change as necessary to prevent pressure drop.

Check all filters; clean or replace as necessary.

Inspect analytical valves for wear and proper operation; replace as

necessary.

Check physical condition of analyzer for corrosion, rust, etc.; take

corrective action as necessary.

Fig. 4.1. Maintenance Schedule

4.2.1 Gas cylinder replacement

When you use two cylinders to supply a gas, connect the cylinders in an automatic switchover configuration to ensure

continuous flow to the analyzer when replacing an exhausted cylinder. In this configuration, the second cylinder switches in

automatically when the first cylinder is exhausted (100 psig or less). When your inspection indicates an exhausted cylinder,

replac

When you use a single cylinder to supply a gas, check the cylinder regularly and replace it when the pressure falls below 100

psig, using another cylinder containing the specified gas.

4.2.2 Cleaning

Prior to cleaning the analyzer, turn off the power to the unit. Avoid using chemical agents which might

damage the component parts of the analyzer.

Clean the analyzer as often as environmental conditions require. Accumulation of dirt in certain oven subassemblies can cause

overheating and component failure, because dirt on components acts as insulating material preventing efficient heat

dissipation.

Remove loose dirt accumulated on the outside of the analyzer with a soft cloth or a small paint brush.

Remove any remaining dirt with a soft cloth dampened in a mild solution of water and detergent. Do not use abrasive cleaners

on the analyzer.

Remove dust in the inside of the oven, to eliminate electrical conductivity, and possible short circuits under high humidity

conditions.

The best way to clean the interior is to dislodge the accumulated dust with dry, low-velocity air and then

remove any remaining dirt with a soft paint brush and vacuum cleaner.

4.3 System backup

Before attempting any maintenance on an analyzer, confirm that a current backup of the operating system and configuration

files are available. If unavailable, follow the instructions in the Diagnostics and Troubleshooting section of this manual to

complete the process following the procedures in the Software paragraphs of that section.

4.4 USB connectors

The SBC contains three Universal Serial Bus (USB) connectors. The USB port on the right, USB3. (J12) is used for backup,

restoring and upgrading the analyzer’s software and firmware. USB2 (J11) and USB1 (J10) are used for the Master Controller

keypad and touchscreen connectors, respectively (see Figure 4.2).

  • WOODWARD ProAct Positioner (Flex I/O)
  • WOODWARD ProAct Positioner (16 pin), 3rd Generation
  • WOODWARD ProAct 75 Speed Control ( 1st Generation)
  • WOODWARD R-Series Actuators
  • WOODWARD F-Series Positioners
  • WOODWARD DVP Digital Valve Positioner
  • WOODWARD GSOV25HT Gas Fuel Shutoff Valve, 2.0”Flange
  • WOODWARD GSOV80 Gas Fuel Shutoff Valve, 2.0” Flange
  • WOODWARD USOV Universal Shutoff Valves
  • WOODWARD LSOV25 Liquid Fuel Shutoff Valve
  • WOODWARD LQ25 Standard Valves
  • WOODWARD LQ6 Liquid Fuel Valve Actuator with On-board Driver
  • WOODWARD GS50 Gas Fuel Valve Actuator with On-board Driver
  • WOODWARD GS40 Gas Fuel Valve Actuator with On-board Driver
  • WOODWARD Turbine Shutdown Trip Block Assemblies
  • WOODWARD TM Actuators (Linear)
  • WOODWARD CPC-II Current-to-Pressure Converter
  • WOODWARD UG Actuators
  • WOODWARD UG25+ Actuators
  • WOODWARD UG25+ Governors for Steam Turbines
  • WOODWARD TGE Turbine Actuators
  • WOODWARD TG611 speed controller
  • WOODWARD TG Turbine Governors
  • WOODWARD MicroNet™ System Modules
  • WOODWARD Flex500 Platform
  • WOODWARD 2300E Electronic Load Sharing and Speed Controls
  • WOODWARD 5009XT Steam Turbine Controls
  • WOODWARD 505 Steam Turbine Controls
  • WOODWARD Peak200 Steam Turbine Controls
  • WOODWARD 2301E-ST Steam Turbine Controls
  • Woodward Industrial Turbine Products
  • DANAHER MOTION 522S65URL6000/522S65URL6000 linear guide rail
  • DANAHER MOTION TG10K259-A00X3 16 / TG10K259A00X31 6 LINEAR UNIT, MOVOPART
  • DANAHER MOTION 2AB16ARBTL/2AB16ARBTL Linear actuator machine parts
  • DANAHER MOTION TG10K259-A00X3 46/TG10K259A00X34 6 servo stepper motor driver
  • DANAHER MOTION 146U-3 / 146U3
  • DANAHER MOTION TG10K259-C35X3 81 / TG10K259C35X38 1
  • Xycom 95212B-001 Module Circuit Board Card 95213-007 8503 PCB PWA Programmable Logic Controller
  • Xycom 97951-025 2112-MD Option Module Component
  • Xycom Automation PL3115T Industrial Touch Monitor
  • Xycom Automation XT1502T Pro Face
  • Xycom 89060B circuit board
  • XYCOM 92023-001 DMA 90440C 1592 CIRCUIT board
  • Xycom AIN XVME-560 Analog Input Module 70560-001
  • Xycom 8450 LCD screen upgrade with cable kit 14 inch CRT
  • Xycom 4850 LCD monitor 12 inch upgrade with cable kit
  • DANAHER MOTION MB1296DN01-3Y / MB1296DN013Y
  • DANAHER MOTION 9T92A47 / 9T92A47
  • DANAHER MOTION MB1256DN01-6Y / MB1256DN016Y
  • DANAHER MOTION 15M146U-3 / 15M146U3
  • DANAHER MOTION 15M246U-3 / 15M246U3
  • DANAHER MOTION 60MB1296DU-18Y / 60MB1296DU18Y
  • Xycom 9450 Interface Screen Monitor
  • Xycom Automation 99141C-001
  • XYCOM XVME-957 VMEBUS Mass Storage Subsystem No Hard Disk
  • Xycom 602939-01 XVME-203/293 Counter Module 70203-00
  • PROFACE PFXGP4501 TADO Pro-face Xycom HMI Operator Panel
  • Xycom 81987-001/81987-001-D Universal I/O Board
  • Xycom Pro-face 5015/R2 Industrial Flat Panel Touch Monitor PM-1
  • Xycom 91195A PanelView Circuit Board
  • XYCOM 93533-001 REV A 93182A2 PORT 3 PORT 4 BOARD
  • Xycom Aout XVME-530 Vme Bus 71530D 70530-001 Platte
  • Xycom P/N: 94144-002 CPU Board
  • XYCOM AOUT XVME-530 VME BUS 71530D 70530-001 BOARD
  • Xycom 602939-01 XVME-203/293 Counter Module 70203-00
  • Xycom 93533-001 Rev A 93182A2 Port 3 Port 4 Platte
  • MOTOROLA F7509/V103/V367 Remote Terminal Unit
  • MOTOROLA F7509/V102/V367 high performance Remote Terminal Unit
  • MOTOROLA FLN4235/FCN6650/FCN6599/FLN4235A adapter power supply
  • MOTOROLA FPN1904 power adapter
  • MOTOROLA FPN1903 100-240V AC power supply
  • Motorola FKN8377 Battery Thermistor Cable
  • Motorola FLN3569 Control Module
  • Motorola FLN3566A 8 Analog Input
  • MOTOROLA FLN3524/FCN6650 adapter power supply
  • MOTOROLA FLN3524/FCN6650/FCN6599 processor module
  • MOTOROLA FLN3524/FCN6650 series
  • XYCOM MOTION 1300-00010000000000H Operating Interface 100-120 VAC
  • Xycom Automation XT1502T Pro Face
  • XYCOM PRO-FACE 1547 (1547-0011310130000)
  • PRO-FACE XYCOM 1546 Heavy Industrial PC 1546-102011010001
  • PRO-FACE XYCOM 1546 Heavy Industrial PC 1546-1020310130001
  • XYCOM Automatic 9987 Operating Interface PN.9987-3338-2100 Computer Board
  • PHILIPS PG 1220 SERIES WITH CPU BOARD, XYCOM XVME-491 , CNC SERVO CONTROLLER
  • XYCOM 3512KPT 139649-002A DHL
  • XYCOM XVME-202 Controller Module Board
  • Xycom Automation Pro-face Model 4115T Pentium 4 2GHz 640KB RAM
  • PRO face Xycom 1341 egemin PM-070016 computer P/N 701301-01
  • Xycom 2050T interface workstation 1.12/. 70AMP 110/240Vac 12
  • XYCOM 1546 PROFACE Industrial Computer with RS View 32 Batch Q302
  • PRO-FACE XYCOM 1546 Heavy Industrial PC 1546-1120310130001
  • Xycom Automation XT1502T Pro Face LAT PANEL INDUSTRIAL MONITOR
  • Xycom Pro Face 1546 Industrial Computer 2000-1000-DVDW-XP
  • Xycom Automation XT1502T FLAT PANEL INDUSTRIAL MONITOR
  • XYCOM AUTOMATION 1300-0001000000000 100-240VAC 0.5A UNMP
  • Xycom 2000T 97957-101 97957101 Operator Interface Panel with 2112-MEM
  • LCD monitor upgrade for 14 inch Xycom 9450 and Xycom 9403 control with cable kit
  • Xycom 2060 LCD Upgrade Monitor with Cable Kit 12 inches
  • Xycom 9450 14-inch LCD monitor upgrade with Cable Kit
  • XYCOM XVME-956 Optical Disc Module XVME956
  • XYCOM Pro-Face 3712 KPM Industrial PCs
  • XYCOM XVME-400 70400-001 card
  • Xycom 3515 KPM PM101906 Operator Interface
  • Xycom AOUT XVME-530 P/N 70530-001 FREV 2.2L
  • Xycom XVME-100 RAM Memory Module
  • GE SR489-P5-LO-A20-E relay protection
  • KONGSBERG DPS132 positioning system host navigation ship
  • PRO-FACE XYCOM 1546 Heavy Industrial PC 1546-1020310130001
  • Xycom XVME-660 processor module 70660-716
  • Xycom 10330-00800 board
  • XYCOM 4860 A PLC
  • Xycom 81625DA control board 81625
  • Allen Bradley 91195A circuit board programmable for A-B Xycom terminals
  • Xycom 94354-001 display screen 94354001 8503 HMI front panel
  • XYCOM 8100-0272A Brown Output Sensor Board
  • Xycom 9485 Automatic CY
  • Xycom XVME-244 DIO Digital Input/Output Card Module 70244-001 VME Bus
  • XYCOM XVME-400 70400-001 card
  • ADEPT TECH/XYCOM 70244-702 10330-00800 PC board
  • XYCOM AIO XVME-540 Analysis of I/O Module
  • XYCOM 2050 Warranty&Extended Technical Support
  • XYCOM 81625DA Control Board
  • XYCOM 70600-001 PC board 70600001 REV 1.4
  • Xycom XVME-979 Rev. 1.1 CD-ROM/HDD/FDD interface card/module suitable for MV controller
  • XYCOM XVME-100 70100-001 card
  • PHILIPS PG 1220 SERIES WITH CPU BOARD, XYCOM XVME-491 , CNC SERVO CONTROLLER
  • Xycom 96574-001 module circuit board 96529-001 8503 PCB PWA programmable
  • ABB 3BDH000031R1 FI 820F Fieldbus Module Serial