ABB PSTX470-600-70 Fully intelligent soft starter
❤ Add to collection

ABB PSTX470-600-70 Fully intelligent soft starter

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

The PSTX series soft starter is a combination of ABB's rich experience in industry applications and deep understanding of special application requirements,

On the basis of years of product research and development, a new fully intelligent motor control and protection product has been launched. It has added many new features

The functionality has been improved and the reliability of the application has been enhanced.

25000.00
¥25000.00
Weight:3.500KG
Quantity:
(Inventory: 10)
Consultation
Accessories
  • YOKOGAWA FCN Aut
    Original :¥8574.00
    With a price :¥8574
    Quantity  
  • Emerson M-series
    Original :¥10000.00
    With a price :¥10000
    Quantity  
  •   
    Original :¥
    0.00
      
      With the total price :¥
    0.00
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

The PSTX series soft starter is a combination of ABB's rich experience in industry applications and deep understanding of special application requirements,

On the basis of years of product research and development, a new fully intelligent motor control and protection product has been launched. It has added many new features

The functionality has been improved and the reliability of the application has been enhanced.




ABB PSTX470-600-70 Fully intelligent soft starter

Three phase control

Rated operating voltage: 208-690 VAC

Rated control power supply voltage:

100 – 250 V, 50/60 Hz

PSTX rated operating current: 30-1250 A

(Maximum internal connection: 2160 A)

Both internal and external connections are acceptable

Control board with protective coating

Can effectively resist dust, moisture, and corrosive gases

Detachable keyboard, protection level IP66 (type 1, 4X, 12)

Graphic LCD display screen, 17 languages to choose from, settings and operation

Make it simpler and more convenient

Built in bypass reduces energy consumption and is easy to install

Integrated Modbus RTU for monitoring and control

Support all mainstream communication protocols

It has an analog output signal that can be selected as the operating current

Voltage, power factor, etc

Emergency fire mode, which can respond to customers in case of emergency

Set the user to disable the protection function and forcefully run the motor

Liming mode, accidentally damaged one phase thyristor in PSTX

In this case, the starting motor can be quickly reset.

The motor preheating function ensures safe starting of the motor.

Power braking helps to quickly stop rotating devices such as fans

Load with high inertia


Convenient and efficient lock hole installation hole

PSTX adopts a lock eye shaped mounting hole, which is easy and fast to install, saving you valuable time.

Compact, safe, and energy-saving motor starting solution

When your electric motor is running at full speed, the built-in bypass can reduce energy consumption. Simultaneously reducing heat

Quantity production means you can reduce your investment in refrigeration equipment. PSTX full series built-in

The bypass has been rigorously tested and verified by ABB.

Customizable main interface

PSTX comes pre installed in 17 different languages, and you can also root it

Customize a unique main interface according to actual needs (up to)

7 pages, 21 items). You can customize the main interface through

To display some important operational status information, while also

You can block some unimportant parameters.

Easy and convenient operation

Large screen graphical display with built-in help menu, allowing you to

Can use PSTX in a simple and fun way. Human computer interface and others

The interface of ABB products is similar, making it convenient for on-site operators

Employees receive training.

Separable keyboard

PSTX comes standard with a detachable keyboard that can be installed in the control panel

On the cabinet door, you can check the shipment without stopping the machine

Line status information or change setting parameters.


Conventional start-up

External connection

PSTX30 PSTX37 PSTX45 PSTX60 PSTX72 PSTX85 PSTX105 PSTX142 PSTX170 Normal Start

External connection

PSTX210 PSTX250 PSTX300 PSTX370 PSTX470 PSTX570 PSTX720 PSTX840 PSTX1050 PSTX1250

(400 V) kW 15 18.5 22 30 37 45 55 75 90 (400 V) kW 110 132 160 200 250 315 400 450 560 710

IEC, Max. A 30 37 45 60 72 85 106 143 171 IEC, Max. A 210 250 300 370 470 570 720 840 1050 1250

(440-480 V) hp 20 25 30 40 50 60 75 100 125 (440-480 V) hp 150 200 250 300 400 500 600 700 900 1000

UL, Max. A 28 34 42 60 68 80 104 130 169 UL, Max. A 192 248 302 361 480 590 720 840 1062 1250

400 V, 40 ºC 400 V, 40 ºC

Use circuit breakers for motor protection or

Plastic shell circuit breakers can achieve "1"

Type coordination and cooperation requirements. 1)

Molded case circuit breaker (50 kA) used for motor protection circuit breaker

Circuit breakers or molded case circuit breakers can achieve

Coordination and cooperation requirements for "1". 1)

Molded case circuit breaker (50 kA)

XT2S160 XT4S250 T4S320 T5S400 T5S630 T7S800 T7S1250 E2.2N 2000

Using gG fuses can achieve "1"

Type coordination and cooperation requirements. If we want to achieve

To meet the requirements of Type 2 coordination and cooperation,

Quick fuses must be used. 1)

Fuse protection (80 kA), fast acting fuse, Bussmann

Using gG fuses can achieve

Type 1 coordination and cooperation requirements.

If we want to achieve a "2" type collaboration

Adjustment and coordination requirements, must be used

Quick fuse. 1)

Fuse protection (80 kA), fast acting fuse, Bussmann

170M1567 170M1568 170M1569 170M1571 170M1572 170M3819 170M5810 170M5812 170M5812 170M5813 170M6812 170M6813 170M6813 170M6814 170M8554 170M6018 170M6020 170M6021

Recommended isolation switch fuse. 1)

Recommended isolation switch fuses

The device. 1) Isolation switch fuse

OS32G OS63G OS125G OS250 OS400 OS400 OS630 OS800 -

The soft starter itself does not require a main circuit

Contactors, but usually release when overloaded

Buckling is used to disconnect the circuit. 1)

The main circuit contactor soft starter itself does not require a main circuit

Circuit contactor, but usually

Used to disconnect power during overload tripping

The road. 1)

Main circuit contactor

AF30 AF38 AF52 AF65 AF80 AF96 AF116 AF140 AF190 AF205 AF265 AF305 AF370 AF460 AF580 AF750 AF1350 AF1650 -

There must be overload protection components to protect the electricity

Motivation. 1) Electronic overload relays must have overload protection components to protect them

Protect the electric motor. 1) Electronic overload relay

Built in

1) The above table is an example of short-circuit coordinated protection. For more examples, please refer to: applications.it.abb.com SOC

Isolation switch fuse group

Used for the recommended quick fuse.

Main circuit contactor

Non essential component, generally used for overload tripping.

Molded case circuit breaker

If only plastic case circuit breakers are used, the requirements of type 1 can be met. (Type 1: Contact required

The device and soft starter should not cause harm to people or equipment under short-circuit conditions, and should not be repaired without repair

Before replacing the parts, it is not allowed to continue using them

Quick fuse protection

To meet the requirements of Type 2, a fast fuse is required. (Type 2: Contactor required

The soft starter should not cause harm to people or equipment under short-circuit conditions, and can continue to operate

Usage: Contact welding is allowed, but the manufacturer should specify the method used for equipment maintenance

The law

Conventional start-up

PSTX210

PSTX250

PSTX300

PSTX370

PSTX470

PSTX570

PSTX720

PSTX840

PSTX1050

PSTX1250

External connection

(400V) kW

one hundred and ten

one hundred and thirty-two

one hundred and sixty

two hundred

two hundred and fifty

three hundred and fifteen

four hundred

four hundred and fifty

five hundred and sixty

seven hundred and ten

IEC, Max.A 210

two hundred and fifty

three hundred

three hundred and seventy

four hundred and seventy

five hundred and seventy

seven hundred and twenty

eight hundred and forty

one thousand and fifty

one thousand two hundred and fifty

(440-480V) hp

one hundred and fifty

two hundred

--+-*+--

two hundred and fifty

++-----+-

three hundred

--- --+ +---

four hundred

---..----

five hundred

-..-+---

six hundred

seven hundred

nine hundred

...+---*-+

one thousand

.------+---

UL, Max. A

one hundred and ninety-two

two hundred and forty-eight

three hundred and two

three hundred and sixty-one

four hundred and eighty

five hundred and ninety

seven hundred and twenty

eight hundred and forty

one thousand and sixty-two

one thousand two hundred and fifty

400 V, 40℃

Use a circuit breaker for motor protection

Circuit breakers or molded case circuit breakers can achieve

Molded case circuit breaker (50 kA)

Coordination and cooperation requirements for "1"

T4S320

T5S400

T5S630

T7S800

T7S1250

E2.2N2000

Using gG fuses can achieve

Type 1 coordination and cooperation requirements.

Fuse protection (80 kA), fast acting fuse, Bussmann

If we want to achieve a "2" type collaboration

Adjustment and coordination requirements, must be used

170M5812

170M5813

170M6812

170M6813

170M6813

170M6814

170M8554

170M6018

170M6020

170M6021

Quick fuse

The recommended isolation switch is blown

The tool

Isolation switch fuse

OS400

OS630

OS800

The soft starter itself does not require a master

Circuit contactor, but usually

Main circuit contactor

Used to disconnect power during overload tripping

AF205

AF265

AF305

AF370

AF460

AF580

AF750

AF1350

AF1650

  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives
  • ABB MNS iS motor control center
  • ABB Condition MonitoringMService