K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB Binary Input Initiator PEB 01 H&B Contronic
❤ Add to collection

ABB Binary Input Initiator PEB 01 H&B Contronic

+86-15305925923
Mr.Wang
wang@kongjiangauto.com
Binary Input Initiator PEB 01 H&B Contronic
8873.00
¥1971.00
Weight:2.000KG
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description
Binary Input Initiator PEB 01 H&B Contronic

ABB Binary Input Initiator PEB 01 H&B Contronic

Functional Features

Alarm information display function

Multi-Channel Alarm Display: It can receive and display alarm information from multiple channels at the same time. These channels can correspond to different equipments, system modules or monitoring points. For example, in a large factory automation system, alarm channels can be set up separately for equipments in different workshops, such as production line equipments, power equipments, environment monitoring equipments, etc. Alarm information of each channel can be clearly displayed on the panel.

Detailed alarm content presentation: For each alarm signal, not only the occurrence of the alarm will be displayed, but also provide detailed alarm content. This includes the type of alarm (e.g. fault alarm, abnormal status alarm, over-limit alarm, etc.), the name or number of the alarmed device, and the alarm time. For example, when a motor over-temperature alarm occurs, the panel displays “Motor XX over-temperature alarm, Occurrence time: XX time XX minutes on XX day, XX month, XX year,” allowing the operator to quickly understand the key information of the alarm.

Visualization and Ease of Operation

Intuitive interface design: Adopting intuitive graphical interface or clear text display makes it easy for the operator to quickly recognize the alarm information. Alarm information may be highlighted by different color indicators (e.g. red for serious alarms, yellow for general alarms), flashing effects or eye-catching text. For example, in a chemical process control system, urgent safety-related alarms (e.g. pressure overrun) are displayed in red flashing text in the most prominent position on the panel.

Convenient operation buttons: The panel is equipped with operation buttons for operators to acknowledge, reset or query detailed information on alarms. The layout of these buttons is ergonomic and easy to operate. For example, when an alarm occurs, the operator can stop the alarm sound and mark the alarm status as viewed by pressing the “Acknowledge” button; the “Reset” button allows the alarm to be restored to its initial state after troubleshooting.

Integration capability with system

Abundant communication interfaces: It is equipped with a variety of communication interfaces, which can be integrated with various industrial automation control systems. It can communicate with PLC (Programmable Logic Controller), DCS (Distributed Control System) or other monitoring devices through RS-485, Ethernet and other interfaces to receive alarm information. For example, in an automated production line based on PLC control, the NADS01 panel connects with the PLC through the RS-485 interface to obtain real-time alarm signals from the production line equipment.

Compatible with multiple protocols: It supports common industrial communication protocols, such as Modbus, Profibus, etc., ensuring smooth data exchange with equipment and systems from different manufacturers. This allows it to be flexibly integrated into existing industrial automation system architectures without the need for large-scale modifications to the entire system. For example, in a mixed system with both ABB and other brands of equipment, the NADS01 panel can efficiently receive and display alarm messages from all devices by supporting multiple protocols.

Technical data

Display parameters

Display type and size: typically a liquid crystal display (LCD) or light-emitting diode display (LED), the size of which varies according to the specific model, generally between 3 - 10 inches, can clearly display alarm information.

Display resolution and color: the display resolution can meet the requirements of clearly displaying alarm text and simple graphics, for example, the resolution may reach 320 × 240 pixels or higher. Color display capability can generally support monochrome (e.g. black and white) or color display, color display can better distinguish between different types of alarms by color, such as red for dangerous alarms, green for normal state.

Electrical Parameters

Operating voltage and power consumption: the operating voltage is generally in the range of 12V - 24V direct current (DC), this voltage range matches the common power supply in the industrial field, it is convenient to use the standard industrial power supply for power supply. Power consumption: Under normal operating conditions, power consumption is usually between a few watts and a dozen watts, depending on factors such as display brightness, number of alarm messages and update frequency.

Communication parameters

Communication protocols and interface types: As mentioned before, it supports a variety of communication protocols, such as Modbus, Profibus, Ethernet and so on. The communication interface types include RS-485 interface for Modbus and Profibus communication, and Ethernet interface for Ethernet communication; the communication rate of RS-485 interface is generally between 9600bps - 115200bps, while Ethernet interface can support 10Mbps - 1000Mbps communication rate according to the network configuration.

 

 

 



  • Electric tricycle truck, agricultural tricycle, elderly vehicle, warehouse truck
  • GE 8042-CC-85 Carrier extension cable, 0.85m
  • GE 8086-FC-20 20 + 24 pin cables for 8619 (2m)
  • GE 8041-CC-35 Carrier extension cable, 0.35m
  • GE 8085-FC-10 20 + 24 pin cables for 8619 (1m)
  • GE 8034-CC-12 Intrinsically Safe Carrier Extension
  • GE 8082-FC-30 16-pin cable for 8618 (3m)
  • GE 8030-CE-RH Intrinsically Safe Carrier extender, right hand
  • GE 8080-FC-10 16-pin cable for 8618 (1m)
  • GE 8021-CE-LH Carrier extender, left hand
  • GE 8044-CC-20 Carrier extension cable, 2.0m
  • GE 8725-CA-RB Railbus isolator carrier with PFM
  • GE 8712-CA-NS Node services carrier, Profibus-DP LAN
  • GE 8724-CA-PS Intrinsically Safe module power supply carrier
  • GE 8711-CA-NS Node services carrier, screw terminal LAN
  • GE 8723-CA-RB Railbus isolator carrier
  • GE 8606-FT-RT Field terminal, RTD
  • GE 8620-FT-MT Field terminal assembly
  • GE 8604-FT-FU Field terminal, fused
  • GE 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI
  • GE 8601-FT-NI Field terminal, non-incendive (Div 2)
  • GE 8215-DO-IS 4-channel Intrinsically
  • GE 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart
  • GE 8206-TI-IS 8-channel Intrinsically Safe RTD input
  • GE 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart
  • GE 8117-DO-DC 8-channel DO, 2-60Vdc isolated, unpowered
  • GE 8810-HI-TX 8-Channel Safety AI, 4-20mA with HART
  • GE 8142-DO-DC 16-channel Digital Output
  • GE 8140-DI-AC 16-channel Digital Input, 115VAC isolated, sinking
  • GE 8112-DI-AC 8-channel DI, 115Vac non-isolated, module powered
  • GE 8139-SH-DC 126-channel Addressable Smoke and Heat
  • GE 8111-DI-AC 8-channel DI, 115Vac isolated, sinking
  • GE 8133-HI-TX 8-Channel Supervised AI with HART
  • GE 8110-DI-DC 8-channel DI, 24Vdc non-isolated, module powered
  • GE 8109-DI-DC 8-channel DI, 24Vdc isolated, sinking
  • GE 8129-IO-DC 8-channel Supervised Discrete I/O
  • GE 8106-TI-RT 4-channel RTD input
  • GE 8127-DI-SE 32-channel SOE module
  • GE 8105-TI-TC 4-channel THC/mV input
  • GE 8125-DI-DC 32-channel DI, non-isolated, module-powered
  • GE 8104-AO-IP 8-channel AO, 4-20mA
  • GE 8122-DI-DC 16-channel DI, 24Vdc isolated, sinking
  • GE 8103-AI-TX 8-channel AI, 4-20mA
  • GE 8121-DI-DC 16-channel DI, 24Vdc non-isolated
  • GE 8102-HO-IP 8-channel AO, with HART for 4-20mA
  • GE 8119-VI-05 8-channel Voltage Input, 1-5Vdc
  • GE 8101-HI-TX 8-channel AI, 4-20mA with HART
  • GE 8755-CA-NS EBIM carrier
  • GE 8522-EB-MT Ethernet Bus Interface
  • GE 8752-CA-NS Universal Node Services Carrier
  • GE 8515-BI-PN PROFINET Scanner Module
  • GE IC754VBI12CTD Touch Screen
  • GE IC754VGI10MTD Touch Screen
  • GE IC754VBI1OMTD Touch Screen
  • GE IC754VSL12CTD QuickPanel
  • GE IC754VBL12CTD QuickPanel
  • GE IC754CGL12CTD QuickPanel
  • GE IC754CBL12CTD QuickPanel
  • ABB TZIDC Digital Positioner
  • ABB NextMove ESB-2 motion controller
  • ABB Advant Controller 70
  • ABB Advant Controller 250
  • ABB ACS850-04 drive modules
  • ABB IRB 4600 Industrial Robot
  • ABB IRB 910SC SCARA
  • ABB Product specification IRB1200
  • ABB DCV 700 thyristor panels
  • ABB Advant Controller 160
  • ABB Serial Communications Module RS232
  • ABB PP886 Compact Product Suite hardware selector
  • ABB Panel 800 version 6
  • ABB Uvisor™ FAU810 – Flame Analysis Unit
  • ABB Switches Automatic Transfer Switches
  • ABB Dynamic braking / DC drive
  • ABB Automatic Transfer Switch OTM_C_21D
  • ABB Switches Change-over and transfer switches
  • ABB PGC2000 Series Process Gas Chromatograph
  • ABB PGC5000 Series gas chromatographs
  • ABB DBDID Process gas chromatographs
  • ABB Vapor Pressure (RVP) analyzers
  • ABB Distributed busbar protection REB500
  • ABB SYNCHROTACT® upgrade Keep your assets synchronized, safe and productive
  • ABB SYNCHROTACT® Datasheet Synchronizing devices and systems
  • ABB C310 Wall- / Pipe-mount universal process controller
  • ABB AP100 pH/Redox (ORP) cartridge sensors with water-wash option
  • ABB Title this is title and subtitle this is subtitle Power Factor Controller RVC Accurate control and monitoring of capacitor banks
  • ABB FOUNDATION Fieldbus Linking Device LD800HSE EX
  • ABB Remote Terminal Unit RTU560
  • ABB MEASUREMENT & ANALYTICS TEIP11
  • ABB MEASUREMENT & ANALYTICS Navigator 540
  • ABB For electromagnetic flowmeters FXE4000-DE43F
  • ABB COM610 Communication Gateway
  • ABB Symphony Plus S+ Control BRC410
  • ABB Symphony Plus SD Series PROFIBUS Interface: PDP800
  • ABB Symphony Plus SD Series HART I/O: HAI805 and HAO805
  • ABB Symphony Plus S+ Turbine: Auto Synchronizer Module AS800
  • ABB S900 I/O Application-Guide CI920S/CI920B replaced by CI920AS/CI920AB
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB S800 I/O Communication interfaces Compact Product Suite
  • ABB IndustrialIT System 800xA S800 I/O System
  • ABB Advant® Master S100 I/O system
  • ABB Ability™ Symphony® Plus MR Series (Melody Rack)
  • ABB Data Sheet ControlIT Harmony Analog I/O
  • ABB Bailey* network90 Loop Interface/Bus Interface(LIM/BIM)
  • ABB Bridge Controller and Process Bus Adapter BRC-300 and PBA-200
  • ABB Kent Morrisey, Business Development Manager – Harmony Evolution NA Harmony Evolution Options For Process Industries Users
  • ABB Industrial'T System 800xA Harmony/INFI90 System
  • ABB Ability™ Symphony® Plus HR Series Control and I/O
  • ABB AC700F controller with direct S700 I/O
  • ABB ContransIthe family with Instruction Manual for Freelance 2000
  • ABB AC servo motors BSM Series
  • ABB BSD Series
  • ABB ControlMaster CM10 Universal process controller, 1/8 DIN
  • ABB PGC2000 Advance Training Course Synopsis
  • ABB PGC5000 Series gas chromatographs
  • ABB EasyLine EL3000 Series Continuous gas analyzers
  • ABB AO2000 Advance Optima Continuous gas analyzers
  • ABB Advant® Controller 450
  • ABB Advant® Controllers
  • ABB Ability™ System 800xA
  • ABB Advant® Master S100 I/O system
  • ABB SYNCHROTACT®5 Operating Instructions
  • ABB Web Tension Systems with Tension Electronics PFEA111
  • ABB Pressductor Pillowblock Load Cells Vertical Measuring PFCL201
  • ABB Force Measurement Products Cold rolling and processing of steel
  • ABB DCS800 Drives
  • ABB MNS iS motor control center
  • ABB Condition MonitoringMService