K-WANG

+086-15305925923
Service expert in industrial control field!
NameDescriptionContent
Adequate Inventory, Timely Service
pursuit of excellence 
Ship control system
Equipment control system
Power monitoring system
Current position:
   
Brand
ABB-CI546-Conveyor Control
❤ Add to collection

ABB-CI546-Conveyor Control

+86-15305925923
Mr.Wang
wang@kongjiangauto.com

The central control station has been fully equipped with ABB Advant OCS control  hardware.

16364.00
¥15345.00
Weight:4.200KG
Quantity:
(Inventory: 123)
Consultation
Product parameters
  • Telephone:+86-15305925923
  • contacts:Mr.Wang
  • Email:wang@kongjiangauto.com
Description

The central control station has been fully equipped with ABB Advant OCS control  hardware.


ABB-CI546-Conveyor Control

The central control station has been fully equipped with ABB Advant OCS control  hardware. A fast and secure transmission protocol couples to the AC450 Advant controllers in  the central station the many decentralised components of other manufacturers that  control the mining machines and conveyor lines. Serial interfaces such as MODBUS  could not be used because of the large amount of data to be transmitted. The  standardised Ethernet infrastructure proved to be the only applicable network  solution. The Transmission Control Protocol / Internet Protocol (TCP/IP) was chosen for  transmission. That protocol has been used so far mainly in LAN and WAN but is  getting applied more and more for transmission purposes as well.

The Central Control Station at Jaenschwalde, Germany ABB, Open-pit mining, Cottbus/Germany 4 2.1 Communication Infrastructure Four OTN (Open Transport Network) loops serve as data connections between the  central control station and the individual technological lines. Loop 1 pit Loop 2 overland connection of the F60 overburden bridge Loop 3 Cottbus North Loop 4 pre-cut Thanks to those redundant optical-fibre loops and the OTN nodes it is possible to  transmit the signals of the individual bus systems and video signals to the central  control station.

The Central Control Station at Jaenschwalde, Germany ABB, Open-pit mining, Cottbus/Germany 5 2.2 Communication Infrastructure of the Central Control Station As regards connections of control station components, it is necessary to distinguish  the equipment bus and the process network (PLAN) from the local area network  (LAN). The equipment bus is an MB300 master bus system which has been made  redundant with a view to higher availability. Participants are connected via two star  couplers (for redundancy), executed in 19-inch technology. Participants are the  active components of the “Advant” control system, such as operator stations,  information management stations and computers. The exchange of information between all subordinate units is made on Ethernet basis  via TCP/IP by twisted-pair cable (category 5). Those units, such as servers and client  PCs are divided into sub-networks according to tasks and security aspects. 3. Conveyor Control The CI546 multi-vendor interface of ABB supports TCP/IP and UDP and has  therefore been chosen for coupling the entire coal and pre-cut conveyor system with  the AC450. The drive stations of the coal conveyor line are equipped with A800 controllers, those  of the pre-cut conveyor line with remote-field controllers (RFC). The connection with  the A800 head-station control is made by a WIN 3.11 IPC integrated into the system  that on its part exchanges data with the PLC system via a dual-port RAM.

Zentralleitstand im Tagebau Jänschwalde ABB - Fördertechnik, Cottbus/Germany 7 The gateway PC behaves like a fully transparent protocol converter. The Ethernet  network is connected to the gateway CPC by the OTN communication network. The  distances to be bridged are up to 12 kilometres. For the pre-cut conveyor line 2000 integer words are passed on in the reception  protocol and 600 integer words in the transmission protocol. The total cycle time from  initiating the command in the operator station to the response is on average 800  milliseconds. Later in the year 2000 the A800 drive control systems will be replaced by RFC,  starting with drive station 36. The control concept of the coal conveyor system will  then be adapted step by step to the one of the pre-cut conveyor system.  The hardware configuration of the TCP/IP coupling is shown below:

5. Diagnostics Workplace A diagnostics workplace provided in the new central control station serves for  operative diagnostic checks by means of monitoring the behaviour of individual  electrical components. This is an important help for preventive maintenance.  The tools, specifically selected for each machine type, include · Advant Function Chart Builder Diagnosis of ABB Advant AC 450 · Network Control Center (NCC) Diagnosis of the OTN system · DIGSI Diagnosis of protective devices on  medium-voltage switchgear · PC-Worx Diagnosis of Interbus S · SIMOVIS Diagnosis of inverters · VIBRONET Vibration monitoring · ELCAD View Navigation in the equipment  documentation (single-line diagrams) The information supplied by the ABB control system in the form of · alarm lists · event logs · system lists · system status reports · status records is also used for diagnostic purposes. The diagnostics workplace is the integrating platform for all those tools and unites all  software modules and communication interfaces required for maintenance and  trouble-shooting. The workplace is open for remote access over the network. 5.1 Equipment The diagnostics workplace is equipped with a powerful industrial PC working on the  terminal-server edition of Windows NT 4.0 and a Citrix Metaframe. The monitor and  the keyboard are set up on one desk. An RS232 switch is used for making the necessary RS232 connections. Up to 32  such connections are possible. The selection of the RS232 connection required for a  specific diagnostic tools is made by the software. Print-outs can be made on the printer installed in the central control station. 5.2 Software A menu system is used to facilitate the start-up of individual programmes and help  orientation. The different applications can be chosen and started by an index.  Additional activities that may become necessary, such as software-based switching  of an RS232 channel, are performed automatically. The client software of the Metaframe system (ICA protocol) and the TCP/IP network  connection make the workplace accessible for remote control.


  • NEC NL8060BC26-17 LCD Module
  • ABB Jokab Pluto Safety PLC
  • OMRON NE1A Series Secure Network Controller Operation Manual
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-2200/2210/2220 Compact FieldPoint Intelligent Real time Controller
  • Installation Instructions for KEYENCE XG-8000 Series Line Scan Camera Version Vision System
  • Omron G9SX series flexible safety unit
  • OMRON SYSMAC CPM1A series programmable controller
  • ABB ACH550 frequency converter installation, operation and maintenance instructions
  • IDEC MicroSmart FC6A PLC CPU Module
  • Gefran GILOGIK II Distributed I/O and Control System
  • GE VersaMax Nano/Micro PLC
  • Nastyaer GIV50-11 Position Limit Switch
  • Rockwell Trusted T8111 TMR Processor
  • TIANMA NL8060BC21-11KG 8.4-inch TFT LCD module
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H series DC/DC power module
  • SIEMENS QBE3000-D/QBE3100-D Differential Pressure Sensor
  • Huichuan H3U series PLC
  • Phoenix ILC 1X1 Series Inline Controller
  • Allen‑Bradley Lifeline ™ 4 Pull rope emergency stop switch
  • Gardner Denver DELCOS 3100 Controller
  • Mitsubishi GOT2000 series graphic operation terminal
  • EBW Series current detection resistor
  • Mitsubishi MELSEC AnS (H) series CPUs
  • Honeywell TN3801 Electric Pneumatic Liquid Level Measurement Cabinet
  • ABB PSR/PSRC/PSE/PSTX series soft starter
  • GE HYDRAN ® 201i Transformer Online Monitoring System
  • ABB NextMove ESB-2 motion controller
  • CAREL PGD graphic display handheld device
  • Hiossen EK implant system
  • Eaton 9PX Series UPS Installation and User Instructions
  • Airlec RYP series precision pressure reducing valve
  • Schneider Modicon M258 Logic Controller
  • KEYENCE XG-7000/8000 Series Visual System New Function Manual
  • Alfa Laval EPC 70 upgrade for separators with EPC 50
  • Nidec Unidrive M700/M701/M702 frequency converter
  • Mitsubishi A171SCPU Motion Controller
  • YASKAWA DX200 Robot Function Pack Manual
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Cambridge Lee Copper Tube
  • TAIYO LX series brushless AC generator
  • Automate Direct DL06 Micro PLC
  • Kepco BOP Bipolar Power Supply Operating Instructions
  • Pilz PNOZmulti Classic/Mini Safety Mini Controller
  • HMS Airbus X-gateway Industrial Protocol Gateway
  • Nidec Control Techniques Unidrive SP AC Variable Frequency Governor
  • GE SPEEDTRONIC ™ Mark VI Gas/Steam Turbine Control System
  • Instructions for using LK-TECH MGv2 servo motor
  • Zebra EPL2 Programming Language Programming Guide
  • How to install Elmo Gold Whistle digital servo drive?
  • MITSUBISHI ELECTRIC FR-D700 frequency converter
  • Edwards EST3 Emergency Communication and Life Safety Platform
  • ABB ACS380 mechanical frequency converter
  • MITSUBISHI ELECTRIC MELSEC iQ-R/System Q/L series PLC family
  • Rockwell Automation Bulletin 5069 Series Controllers
  • CODESYS Control Win SL
  • ABB AC 800M controller and communication interface
  • Honeywell 7800 Series EC/RM7830A/7850A Combustion Relay Module
  • Rockwell AutoMax Distributed Power Drive System Manual
  • SNO 4062 K/KM safety relay
  • World Encoders iPHD/iHDW series handheld electronic handwheel
  • Copes Vulcan turbine bypass system (CV-1163)
  • ZF Marine MM9000 ClearCommand Marine Propulsion Control System
  • Pro face GP-2400/2500/2600 Series Operating Manual
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller
  • Metso DNA Device Status Monitoring System
  • ABB Millmate Rolling Mill Force Measurement System
  • Reliance Electric GV3000/SE AC Inverter
  • EUCHNER handheld operating unit and electronic handwheel
  • GE Fanuc Automation VersaMax ® I/O and Control
  • Microchip dsPIC30F series 16 bit high-performance digital signal controller
  • Milacron ELEKTRON 400/500/600 series fully electric injection molding machine
  • PRECILEC RE.0444N series DC tachometer generator
  • Mitsubishi GOT2000/GOT1000 series serial communication unit
  • Keyence GS series safety interlock switch
  • GE AT868 AquaTrans ™ Single/dual channel ultrasonic water flow transmitter
  • MITSUBISHI ELECTRIC GOT1000 Series Connection Manual
  • Allen Bradley Guardmaster GSR Safety Relay
  • Delta AH500 PLC Operating Instructions
  • Pilz PNOZmulti series safety control system
  • Operation Instructions for Pilz PNOZ XV3P Safety Relay
  • Pilz PZE 9 Safety Relay Expansion Module
  • SCHNEIDER TSX Premium P57 Processor and Discrete I/O Modules
  • KONGSBERG High Precision Acoustic Positioning – HiPAP®
  • KONGSBERG Seatex MRU 5 The Ideal Marine Motion Sensor
  • KONGSBERG BWMS Bridge Watch Monitoring System
  • WCU Watch Cabin Unit - LED version
  • Albatross Control System NMEA 2000 ® Standard modular shipborne monitoring and control system
  • KONGSBERG Simrad PI50 Catch monitoring system
  • Kongsberg C-series CNC cutting machine
  • KONGSBERG RCU500 Remote Controller Unit
  • Operator Manual for AutroSafe Interactive Fire Detection System (Release 4)
  • EAU-321 is an AutroSafe fire detection system
  • Installation and usage instructions for MTL4850 HART multiplexer
  • MITSUBISHI ELECTRIC FR-A500 Series Inverter Manual
  • Laumas TLM8 8-channel weight transmitter
  • General User Manual for the Anybus X-gateway Series Industrial Gateway
  • Instructions for Using NJ/NX Series CPU Unit OPC UA
  • OMRON Machine Automation Controller NX-series System Units
  • FANUC Series 16i/18i/21i MODEL B Series CNC System Hardware Connection
  • PILZ PNOZmulti Classic and PNOZmulti Mini configurable safety controllers
  • MITSUBISHI ELECTRIC MELSEC A series Programmable Controller
  • Renishaw PHC10-3 PLUS Probe Controller Installation Guide
  • Hine Automation Constellation series vacuum wafer transfer system
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental rotary encoder
  • Programming Guide for Modicon 884 Programmable Controller
  • Eaton LZM series molded case circuit breaker
  • Pilz PSWZ X1P Safety Static Monitoring Relay
  • Keyence CV-3502P/CV-3000 series visual system
  • Pro face GP2400/2500/2600 series programmable human-machine interface (HMI)
  • Siemens SINAMICS S120 AC frequency converter
  • Allen Bradley 160-IB1 InterBus Communication Module
  • MX321 AVR Automatic Voltage Regulator
  • GE Multilin MM2 Motor Manager 2 Manual
  • SIEMENS C500 microcontroller family architecture and instruction set description
  • HORIBA SEC-Z500X Series Digital Mass Flow Controller
  • QUBE Servo 2 integrated rotary servo teaching experimental platform
  • Schneider Telemecanique TSX17 Micro PLC Communication Module
  • GE DC Drives (BCH series) DC Speed Governor
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB COMBIVERT F5 elevator dedicated frequency converter
  • TOSHIBA TOSBERT VF-S15 Inverter Description
  • LS Power Generation SV-IG5A Series Inverter Easy Operation Instructions